Tender For corrigendum : supply of steam water analysis system main spares and e and c - ph sensor , ph transmitter 4 to 20ma hart , specific conductivity sensor , specific conductivity transmitter 4 to 20ma hart , cat ion conductivity sensor with 1 cat ion exchange column , cat ion conductivity transmitter 4 to 20ma hart , do2 sensor , do2 transmitter 4 to 20ma hart material code , silica analyzer transmitter 4 to 20ma multi channel , sodium analyzer transmitter 4 to 20ma multi channel , hc analyzer 4 to 20ma , sample handling system for main steam superheated , sample handling system for drum water , sample handling system for hp feed water economizer inlet , sample handling system for deae ol fw , sample handling system for dm water , sample handling system for condensate blow down line , sample coolers , redundant chiller units 1 working 1 standby , shelf life items required at the time of commissioning , shelf life items required after commissioning in 1st lot , shelf life items required after commissioning in 2nd lot , training as per cl 14 of 2 mandays for 6 nos at site , supervision of e and c services charges at site , supervision of e and c visit charges , mandatory spares as per tech specs
Tender For work of attending leakages by replacing damaged plates and patching of vertical duct from economizer outlet to air preheater in unit 3 during coh at cstps, chandrapur.
Tender For tender for straight heat shield with two nos. clamps for water wall tube dia. 63.5mm , straight heat shield with clamps for ltsh straight for tube dia. 44.5mm , heat shield with clamps for water wall screen straight tube for tube dia. 76.1mm , heat shield with clamps for s.h. screen and hanger tubes of dia. 51mm , straight heat shield with clamps for economizer tubes of dia. 32mm , straight heat shield with two nos. clamps for sh and rh tube dia 48 mm , ss rod 10mm
Tender For overhaul works on boiler pressure parts for replacement of eroded tubes of ltsh, back-pass and economizer tubes and metal filling on eroded tubes where ever required after d-meter survey, inspection, fixing and adjustment of erosion protection shields at unit-6/stage-iv/dr.mvr rtpp during annual overhaul period 2026-27.
Tender For bid to ras supply of top and bottom economizer panels d d - top economizer coil upper straight , top economizer coils upper staggered , top economizer coils central straight , top economizer coils central staggered , lower economizer loop assembly lh , lower economizer loop assembly rh
Tender For providing of facility management services - lumpsum based - industrial; cleaning of boiler economizer tubes; consumables to be provided by service provider (inclusive in contract cost)
Tender For corrigendum : tender for supply of tubular protector for spacer tube , size l-1000mm , id-55 mm , tubular protector for rear w.w. screen tube , size l-1500mm , id-55mm , tubular protector for final s.h. tube , size l-1000mm , id-55mm , tubular protector for tertiary super heater & reheater size 1500x58.0x4.0 mm , tubular protector for tertiary s.h. tube , size l-1000mm , id-57mm , u clamp of size id-57 mm , u clamp of size id-63mm , tubular protector for economizer & primary s.h. vertical tube , size l-1000mm , id-52mm , tubular protector for economizer & primary s.h. vertical tube , size l-1500mm , u clamp of size id-53mm , tubular protector for pri. s.h. tube , size l-1500mm , id-45mm , u clamp for ash protector of primary sh horizontal size id-45 mm , tubular protector for sec. & ter. rh coil , size l-1500mm , id-64mm , u clamp of size id-65 mm , width 40mm , th.-4.0mm , 90 degree bend tubular shield for primary super heater horizontal size id-45.5 mm , reverse 90 deg bend ash protector for primary sh horizontal size id-45.5 mm , semi circular protector for spacer tube 60 deg bend size-1500x65x4 mm
Tender For corrigendum : supply of spares of soot blowers of (2x600 mw), katpp, rvunl, jhalawar - "lance tube assembly with flange, nozzel and nozzel head pipe.soot blower location: plsh area (ik-1/2/3/4) in u#1& 2 respectively", "lance tube assembly with flange, nozzel and nozzel head pipe soot blower location: plsh area (ik-5/6/7/8/9/10) in u#1& 2 respectively", "lance tube assembly with flange, nozzel and nozzel head pipesoot blower location: fsh (ik-11/12/13/14/15/16), frh (ik-17/18/19/20/21/22),prh(ik-23/24), ltsh(ik-25/26) area in u#1& 2 respectively ", "lance tube assembly with flange, nozzel and nozzel head pipe soot blower location: prh(ik-27/28/29/30, ltsh area(ik-31/32/33/34/35/36)in u#1& 2 respectively", "poppet valve assembly for all lrsbsoot blower location: plsh/fsh/frh/prh/ltsh area", "poppet valve assembly for hrsbsoot blower location: economizer area", "screw tube (lance tube) with packing assembly for fsbsoot blower location: water wall area", "feed tube with flange for fsbsoot blower location: water wall area", "goose neck valve assembly for fsbsoot blower location: water wall area", "lance tube with multi -jet element nozzel assembly for aphsbsoot blower location: air pre-heater area"
Tender For corrigendum : daily cleaning of air heater hoppers, economizer hoppers, mill chambers, slag bath pits and basement area, hsd & hfo,mot & dot, unloading pump house, drains, round the clock in three shifts of ph-i and ph-ii, htps, korba (west)