Web Analytics Made Easy - StatCounter

Medical Gas Pipeline Tenders

Get complete information related to latest Medical Gas Pipeline Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Medical Gas Pipeline Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Medical Gas Pipeline Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :45636287 Due date: 03 Jul, 202603 Jul, 2026 9.00 Lacs
Tender For corrigendum : annual maintenance contract for medical gas pipeline system and allied works at skims mch bemina

corporations/Associations/Others

CTN :45723624 Due date: 02 Jul, 202602 Jul, 2026 6.00 Lacs
Tender For supply delivery and fixing of motor and accessories at ward-1 selliyampalayam oht in narasingapuram municipality - supply and delivery of kirloskar make 15hp/11kw/2900rpm three phase/415v/50hz/ac/tefc horizontal centrifugal monoblock pump impeller-mechanical seal (head-20mtr,flow rate-2154lpm) size:100x100mm (local quotation) 15hp horizontal centrifugal monoblock pump, labour charges for erection of horizontal shaft, centrifugal pumpset (coupled/monoblock) in bore well/open well including fixing of suction pipe and foot valve upto a maximum depth of 7 metres and delivery pipes to the required length with valves,pressure gauges upto the exterior wall of pump room and erection of panel board consisting of tpic switches starter, voltmeter, ammeter, capacitor single phasing preventor and laying and jointing the cables and twinearthing as per ie rules including providing bed blocks etc., complete and operating the pumps and trial run for 10 days including signing of completion of reports as required by eb authorities., three phase panel board star- delta with two level guard and auto start supply and delivery of star-delta starter confirming to is 13947, iec60947-1 and as amended thereafter with suitable kw rating for operation in ac/ three phase/50hz (+/- 5%) and 415v (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 nos., ct operated ammeter (65 mm dia) with suppressed scale,voltmeter (65mm dia),voltmeter selector switch,miniature circuit breaker, thermal overload relay, air break contactors suitable for next standard higher kw rating, single phasing preventor, dry running preventor and on/off push button switches, wiring with 1 sq.mm/4 sq. mm copper pvc insulated cable, powder coated vermin proof box, including the capacitor (the cost of capa citor is to be taken separately). three phase panel board for 15hp, supply,delivery and fixing of the following materials are listed below etc..,as directed by the departmental ofiicers.for service4 core 16sq.mm pvc copper ug cable, for motor3 core 6sq.mm pvc insulated and sheathed flat type copper cable, 150mm di pipe, 100mm gi pipe , 100mm gi flange set, rubber sheet for flange set, ms bolt and nut20mm dia and above x 90mm to120mm length fully threaded bolts andwith nuts 2 nos. , manhole cover 60 x 60cm (heavy duty) with frame, supply, erection, testing and commissioning of cast iron body and bronze internal non-rising spindle sluice valve of sizes at required places to control the flow of water including necessary ms flange of table e , gaskets, bolts & nuts including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the departmental officers. 150mm sluice valve, 100amps 4pole mcb, 100amps porcelain fuse unit (500v), 32mm pipe

Central Government And Public Sector

CTN :45738759 Due date: 10 Jul, 202610 Jul, 2026 40.44 Lacs
Tender For supply of supply of 1.5 tr inverter type ductable ac as per bsnl specifications , itc of 1.5 tr inverter type ductable ac as per bsnl specifications , supply and fixing copper piping of 0.25 inch and 0.5inch with nitrite foam insulation as required , supply and fixing powder coated heavy duty ms stand , supply and fixing upvc pipe 25mm dia, 2mm thick , supply and fixing upvc pipe 40mm dia, 2mm thick , supplying and laying pvc insulated frls copper cable 3x1.5sqmm , supplying and laying pvc insulated frls copper cable 3x2.5sqmm , supplying and fixing dp enclosure with dp mcb , supply and fixing 5a to 32 a sp mcb in extg db as required , supplyinstalling,balancingand commissioning gss sheet ducting 0.63mm thick , supplyinstalling,balancingand commissioning gss sheet ducting 0.80mm thick , providing and fixing supply air grills powder coated , providing canvass connection

CTN :45729683 Due date: 07 Jul, 202607 Jul, 2026 4.19 Crore
Tender For construction of 200 bedded rural hospital with trauma care unit at manor taluka dist palghar (sitc of medical gas pipeline system).

CTN :45721353 Due date: 13 Jul, 202613 Jul, 2026 10.32 Crore
Tender For providing laying and jointing of ac pressure pipe by mazza process of 800 mm dia 4.65 km for main canal 350 mm dia 1.10 km for tangamau minor class 20 as per is code 1592 2003 and is code 6530 1972 with all fittings and outlets as per drawin

CTN :45298008 Due date: 01 Jul, 202601 Jul, 2026 NA
Tender For bid to ras supply of xlpe cable for working voltage up to and including 1.1 kv marked to is 7098 (part 1) (q2) , miniature circuit breakers (mcb) for ac operation marked to is/iec 60898 (part 1) (q2) , supply and fixing on load change over switch ss enclosure complete with capacity 200 amp, 415 volt, 4 pole, 50 hz. , supply and fixing sheet metal enclosure spn db double door having facility to fix mcb spn as incomer and mcbs as outgoing, spn 4 ways, ip-43 , supply and fixing sheet metal enclosure tpn db double door having facility to fix mcb tpn as incommer and mcbs as outgoing tpn 4 ways, ip-43 , supply and fixing bus bar chamber 100 amp, 4 way, 415 volts enclosurre is made from crca sheet of thickness 3.15mm crca sheet cover , supply and fixing of straight through epoxy cable joint kit incl jointing materials making joints of ug electric cable 1100 v grade nominal cross sectional area not exc.50 sqmm, 3.5 by 4 core , supply and fixing straight through epoxy cable joint kit incl jointing materials making joints of ug electric cable 1100 v grade cross sectional area 240 sqmm to 300 sqmm, 3.5 core. , supply and fixing end termination epoxy cable joint kit including jointing materials for making joints of ug electric cable 1100 v grade nominal cross sectional area 240 sqmm to 300 sqmm, 3.5 core , supply and fixing of galvanised iron pipe 100 mm bore dia light grade for protection of ug cable , supply of digging nad layingg in excavation trenches not exc. 1.50 m wide and not exc. 1.50 m in depth, complete all as specified and directed. , returning, filling in including spreading, levelling, watering and well ramming in layers not exc. 250 mm in soft loose soil , supply and fixing of galvanised iron pipe 40 mm bore dia light grade for protection of ug cable , supply, installation, commissioning and testing including providing all necessary electrical connection,lt feeder panel board of size 1.0 m x 0.6 m x ) /bid number : gem/2026/b/7568567 * /dated: 22-05-2026 & & / bid document 1 / 30 & & ' ' /item category 0.5 m , supply, installation, commissioning and testing including providing all necessary electrical connections lt feeder panel board of size 0.6 m x 0.6 m x 0.5 m , supply and fixing earhing complete with gi earth plate electrode of size 600x600x6mm thick.complete all as specified and directed in boq spec file , supply and fixing earhing complete with gi earth plate electrode of size 600x600x6mm thick. complete all as specified and directed in boq spec file , supply and fixing of sub-class b brick, well burnt, laid breadth-wise along the axis of cable laid in trenches over sand cushion laid for ug cable protection, complete all as specified and directed. , supply and fixing horizontal boring under a depth of 0.65 m from the gl for passing pipe upto 40 mm bore dia , supply of digging and laying of removing excavated materials soils not exc. 50 m and depositing where directed at a level not exc.1.50 m , taking down out unserviceable or serviceable lt ug cables of nominal cross-sectional area 300 sqmm including bricks, gi pipes etc. , taking down out unserviceable or serviceable lt ug cables of nominal cross-sectional area 50 sqmm 3.5 core including bricks, gi pipes etc. , supply of digging and laying of sand cushioning dry in trenches for protection of ug cables below, above and around the ug cable laid in trenches of 230 mm spread thickness , cutting road by hard standing and making good disturbed surfaces by using pcc type-c2,1-3-6 by using 40 mm graded stone aggregate , boring of holes under road,pavement,hard standing by trenchless technology using ultra sounding technique including hdpe pipe 150 mm dia suitable for 0.4 mpa working pressure , cutting chases, chipping in making good to facings, where required and pointing in cement mortar 1- 3 to ends or edges of landings, steps, sills, sunshades, shelves, lintels etc. , submain wiring comprising single core 2 runs of 6 sqmm nominal coss sectional area frlh

Central Government/Public Sector

CTN :45163037 Due date: 01 Jul, 202601 Jul, 2026 NA
Tender For bid to ras providing of customized amc/cmc for pre-owned products - medical gas pipeline system; --; comprehensive maintenance contract (cmc); not applicable; yes

Central Government/Public Sector

CTN :45382837 Due date: 04 Jul, 202604 Jul, 2026 NA
Tender For corrigendum : repair/maint of external electric supply system, distribution lt panels with connected items and allied services at other than basistha area under ge guwahati. - excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out / laying of under ground cable, pole or stay and getting out in soft soil strata complete all as specified and as directed., returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cms spread any type of soil complete all as specified and as directed., removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed., supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. (note : punned thickness shall be measured)., m&l for bricks common burnt clay, building brick, sub class b designation 75 old size bricks laid in trenches flat over sand cushioning for cable protection complete all as specified and as directed., m&l for supply and fixing / laying in replacement, connect, test and commissioning of lt under ground cable xlpe insulated, screened, pvc bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor, 1100 volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cable glands,lugs and suitable size of ms saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and as directed.note : manufacturers test certificate shall be submitted alongwith rar/fb to engr-in-charge., (a) 95 sqmm x 3.5 core, (b) 70 sqmm x 3.5 core, (c) 50 sqmm x 3.5 core, (d) 25 sqmm x 3.5 core, supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 630 amps, 50ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 400 amps, 36 ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 250amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 160amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 125 amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 100amps, 26ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 63amps, 16 ka breaking

Central Government And Public Sector

CTN :45714170 Due date: 10 Jul, 202610 Jul, 2026 7.59 Lacs
Tender For supply of sitc of air cooled hi wall 1.5tr inverter type 5 star bee rating split ac unitscomplete with indoor unit complete as per atc , s f of additional copper refrigerant pipe for both iquid , gas vaccumiazation and nitrogen testing as per atcadditional copper refrigerant pipe for both liquid and gas , supplying and laying additional pvc insulated copper conductor cable of size 3 core 2.5 sq.mm as per atcpvc insulated copper conductor cable of size 3 core 2.5 sq.mm , supplying and laying additional pvc insulated copper conductor cable of size 4core 2.5 sq.mm as per atcpvc insulated copper conductor cable of size 4core 2.5 sq.mm , supplying and fixing of additional length of 25 mm dia pvc drain pipe of good quality including clamps as per atc25 mm dia pvc drain pipe of good quality , supplying and fixing of good quality of powder coated ms frame set of ms sheet to accommodate the condenser powder coated ms frame set of ms sheet

State Government

CTN :45702404 Due date: 06 Jul, 202606 Jul, 2026 3.12 Lacs
Tender For dnit for laying,jointing,testing and commissioning of pipe line against the old damaged ac pipe line on urgent bases in village udaka block indri distt. nuh and all other works continegent thereto
 Loading, Please wait...

Connect us via What's Up