Get complete information related to latest Medical Grade Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Medical Grade Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Medical Grade Tenders.
Tender For rate contract for supply of consumables/non-consumables items for the department of cssd - surgical gloves for general routine operations / icu usage: size - 6.0: single use, sterile, disposable, polimer coated powder free, non-pvc, natural latex surgical gloves with finish of smooth inner surface and rough outer surface used for general routine operations. gloves should have high level of tactile sensitivity, secure grip, good resistant to tear, ease of donning and reduction of reflective glare. packing: number of gloves in a pack: 2 nos. (1 pair), outer packing should be poly pouch or lacquer coated peel down paper or blister poly peel. inner packing with medicalgrade paper. packed to maintain sterility during shipping & storage and permit opening without contamination of the gloves. colour: translucent. dimensions: size(number): 6 thickness: 0.20 - 0.24 mm. shelf life: 5 years. the product should have at least 2/3 rd of the total shelf life available at the time of supply. standards: bis certified, confirming is 4148: 1989 (2021) / is 13422: 1992 (2018) or equivalent standards ce / usfda approved. certificates: oem should produce data sheet, certificate of standards, valid licenses, manufacturing units certificates (iso 13485), test reports / proof of sterility from cdsco / central govt./nabl acredited lab to prove conformity to the specifications. pack size: 50 pairs, surgical gloves for general routine operations / icu usage: size 6.5 single use, sterile, disposable, polimer coated powder free, non-pvc, natural latex surgical gloves with finish of smooth inner surface and rough outer surface used for general routine operations. gloves should have high level of tactile sensitivity, secure grip, good resistant to tear, ease of donning and reduction of reflective glare. packing: number of gloves in a pack: 2 nos. (1 pair), outer packing should be poly pouch or lacquer coated peel down paper or blister poly peel. inner packing with medicalgrade paper. packed to maintain sterility during shipping & storage and permit opening without contamination of the gloves. colour: translucent. dimensions: size(number): 6.5 thickness: 0.20 - 0.24 mm. shelf life: 5 years. the product should have at least 2/3 rd of the total shelf life available at the time of supply. standards: bis certified, confirming is 4148: 1989 (2021) / is 13422: 1992 (2018) or equivalent standards ce / usfda approved. certificates: oem should produce data sheet, certificate of standards, valid licenses, manufacturing units certificates (iso 13485), test reports / proof of sterility from cdsco / central govt./nabl acredited lab to prove conformity to the specifications. pack size: 50 pairs, surgical gloves for general routine operations / icu usage: size 7. 0 : single use, sterile, disposable, polimer coated powder free, non-pvc, natural latex surgical gloves with finish of smooth inner surface and rough outer surface used for general routine operations. gloves should have high level of tactile sensitivity, secure grip, good resistant to tear, ease of donning and reduction of reflective glare. packing: number of gloves in a pack: 2 nos. (1 pair), outer packing should be poly pouch or lacquer coated peel down paper or blister poly peel. inner packing with medicalgrade paper. packed to maintain sterility during shipping & storage and permit opening without contamination of the gloves. colour: translucent. dimensions: size(number): 7 thickness: 0.20 - 0.24 mm. shelf life: 5 years. the product should have at least 2/3 rd of the total shelf life available at the time of supply. standards: bis certified, confirming is 4148: 1989 (2021) / is 13422: 1992 (2018) or equivalent standards ce / usfda approved. certificates: oem should produce data sheet, certificate of standards, valid licenses, manufacturing units certificates (iso 13485), test reports / proof of sterility from cdsco / central govt./nabl acredited lab to prove conformity to the specifications. pack
Tender For supply of vet med d d - tick collar for large size dogs , inj phenyl butazone vial of 100 ml , turpentine oil 1000 ml medicalgrade , oxytetracycline spray 100 ml , spray lignocaine 50 ml , liq fenbbendazole 10 percentage bott of 1 ltr
Tender For transcatheter aortic valve implant set consists of the following in sterile individual pack, (i) transcatheter heart valve - 01 unit, it should be made of bovine/porcine pericardium tri leaflet valve, made of medicalgrade alloy with hybrid cell design. it should have internal/exteranl pet skirting or both. the size of the valve should range from 20 mm to32 mm or more. (ii) valve delivery system - 01 unit, the valve should be crimped or loaded over the delivery system prior to insertion into the patients vasculature. should be 0.035 wire compatible. (iii) baloon dialation catheter - 01 unit, baloon size ranges from 16 mm to 25 mm with 30 mm length. the balloon rbp should be minimum 6 atm. (iv) introducer sheath - 1 unit, should be minimum 14 fr and length of minimum 30 cm compatible with all valve sizes. should have haemostatic valve and side port with three way. should be compatible for femoral artery size ranging from 5 mm to 7 mm. (v) inflation device - 02 units (30ml/40ml/60ml). (vi) syringes 50 cc - 02 units. the firm should be able to supply any size of valve, delivery system &baloon suitable for patients. [ai(2025-26) , item code no.s-62279, sl no.2051. ]
Tender For supply of hack saw frame 300mm , hack saw blade 300 x 12 point 5 x 0 point 63 mm , hand grinding machine 5 inch , hand drilling machine 13mm , d by e spanner set 6 to 32 mm , ring spanner set 6 to 32 mm , box bit set with rachet 1by 2 inch , box bit set with rachet 3 by 4 inch , circlip piler inner 6 inch , circlip piler outer 6 inch , circlip piler bent inner 6 inch , circlip piler bent outer 6 inch , screw driver 6 inch flat , screw driver 8 inch flat , allen key set 1 point 5 mm to 10 mm , core cutter 12mm to 32 mm set of 21 nos , measuring tape 5 mtr , measuring tape 3 mtr , tool box metal 5 compartment with lock and key , safe gel hand wash 250gram pack , m seal small 100 gram pack , teflon tape 1by 2 inch make diamond , safety goggles , heat resistant gloves 8 inch , surgical gloves 50 pair pack , felt 20mm thickness x 1point8 mtr width , felt 10mm thickness x 1point8 mtr width , white paint 1ltr enamel , black paint 1 ltr enamel , blue paint 1 ltr enamel , navy blue paint 1 ltr enamel , orange paint 1 ltr enamel , yellow paint 1 ltr enamel , red oxide paint 1 ltr enamel , tinner 5 ltr enamel , banian cloth fine white , super multi grade engine oil 20w40 20 ltr drum , heavy duty brake fluid dot 4 500ml pack , hss tap set 7by 16inch x 50 unf
Tender For corrigendum : sch 5 drugs, pharmaceutical and disinfectants by tender - schedule v (drugs, pharmaceuticals & disinfectant), carbolic (phenol crystal) acid, ammonium chloride, borax, crystal violet medicinal use, emulsifying wax, ether solvent, methyl salicylate, paraffin soft white, potassium chloride, potassium iodide, soda lime granules medicalgrade for anaesthesia purpose. non-hygroscopic . granules size 4-8 mesh size. suitable indication with change of colour to denote exhaustion of granules. (rate to be quoted for 1 x 5 kg tin) i.p., sodium bicarbonate, calamine prepared, clove oil, soap solution i. s. i. mark, antiseptic solution containing benzalkonium chloride solution 20% w/v equivalent to benzalkonium chloride equivalent to 10%w/v, 70% to 80% alcohol based surgical dry hand antiseptic with 0.5% to 1% chlorhexidine gluconate and containing suitable emollient and moisturizer., 70% to 80% alcohol based surgical dry hand antiseptic with a substance included in i.p.other than chlorhexidine gluconate having a broad spectrum activity against bacteria, virus (inclusive hiv and hbv) and fungi with suitable emollient and moisturizer., chlorhexidine (not less than 1.5% w./ v. or 7.5 % v/v) with cetrimide 15%, povidone iodine i.p. should contain povidone iodine 10% (available iodine 1% w/v) (rate to be quoted for 1000ml), solution containing > 2 % w/v glutaraldehyde with a powder activator free of surfactants with stable alkaline ph for 14 days with concentration detections strips(10 strips/5lit jar.), surface & environmental disinfectant each 100 gm containing 1.6 dihydroxy, 2.5 diohexane 11.2gm, gluteraldehyde 5gm benzalkonium chloride 5gm alkyl urear derivatives 3.00gm ( effectivity reports against hbv/hiv & t.b. is necessary), surface and environmental disinfectant: aldehyde free disinfec- tant with bacetericidal, fungicidal, virucidal(including hiv and hbv) and sporicidal activity capable of being used as both surface and environmental disinfectant as well as for fogging. the product label should mention the shelf life also., sodium chloride (i.p.), opa orthophthalaldehyde 0.55% w/w with marker technology with detection strips (5 test strips/5 lit pack), enzymatic instrument cleaner multienzymatic enzymatic cleaner, neutral ph, compatible for use on surgical, medical and dental instruments with atleast protease ,amylase,& lipase enzyme activity (rate to be quoted per ltr 1 x 1 ltrs) (supply in suitable packing upto 5 lit. jar), denaturated spirit 95-97% ordinary, analgesic transdermal patch fentanyl 25mcg/hr, adhesive remover spray 100 % silicon, 1 % acetic acid 500 ml bottle, methylene blue, na fluorescence strips, molecular grade water, lint free tissue
Tender For supply of laryngeal mask airway, size 2.5, 3, 4, 5specification:1. it should be a 2nd generation supraglottic airway device.(lma)2. it should be anatomically curved for rapid placement & long-term performance.3. it should be designed to reduce dead space by up to 39%.4. the thin cuff should maintain high seal pressure of up to 40 cmh20.5. it should provide maximum intra-cuff pressure of up to 60 cmh20.6. it should have integrated gastric access channel for managing gastric content.7. it should allow placement of maximum 16 fr of gastric tube through the channel.8. it should have intubation capability using standard et-tubes.9. it should allow placement of maximum 8.0 et tube through the airway.10. should have integrated bite absorption area to prevent airway occlusion.11. cuff and airway tube should be moulded as a single unit for safety %u2013 no separation.12. it should have navigation marks for guiding flexible scope during intubation.13. the pilot balloon should provide mask size & tactile indication of degree of inflation.14. it should have 15 mm (iso- international standard) airway connector.15. it should be made of 100% phthalate free & latex free medicalgraded material.16. it should be mr safe.17. it should be disposable, eliminating chances of cross contamination.18. should be available in all standard sizes 3(30-50kg), 4 (50-70kg), 5(70-100kg) to accommodate specific age group of patients.19. should be us fda, iso certified for quality assurance20. size 3 -2, size 4 -4, size 5-421. brochure to be uploaded with the offer.