Get complete information related to latest Medical Oxygen Gas Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Medical Oxygen Gas Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Medical Oxygen Gas Tenders.
Tender For purchase of sports exercise physiology lap equipments - cardiopulmonary exercise testing system system should be compact can be used in laboratory operation and low maintenance costs and easy servicing. system should be state of the art computerized telemetry breath test analyzer for on-line breath by breath measurement of exercise test of respiratory system to measure following parameter: time, ve, bf(rr), hr, feo2, feco2, peo2, peco2, vo2, vco2, ve/vco2(eqco2), ve/vo2(eqo2), rq(rer), vd/vt, vo2/kg, vo2/kg/hr, met, watt(work), hr, ttot, ti, te, ti/te, ti/ttot, pef, pif, br, vet, sum, tv/te, o2 kinetics, oxygen deficit, oxygen debt parameters and indirect calorimetric. wireless hr recording system, indirect cardiac output by wassermann algorithm system should comply ats and ers guide line and it should be ce certified., iso certified system should have automatic ambient conditions measuring system. system should work under temperature range 0 to 50 celsius. system should have facility for automatic calibration of analyzers. volume transducer calibration with precision calibration syringe. system should meet following technical specification flow rate measurement: measuring headpiece should be either through turbine /dvt/ pneumotach and dead space less then 40 ml, it should not be affected by humidity , flow range +/- 18 l/s and accuracy 2% oxygen analyser : should be either electrochemicalcell/paramagnetic and measurement range 0- 100 %,response time t90 100 ms and accuracy +/-0,04 % and- resolution 0,02 %carbon dioxide analyser : should be ndir (infraredabsorption) and measurement range 0 - 10 %,-response time t90 90 ms , accuracy +/- 0,04 %, andresolution 0,02 % software should support latest windows or latest andin corporate customized predicted normal equations.software should be capable of changing graphics displays during real time testing. system should have facility for automatic treadmill or bicycle ergo meter control. should be supplied with software, standard accessories for operation manual carrying case for field use. system should be supplied with latest data acquisition system, deskjet printer and ups. system should comply en iso 13485:2003, en iso 9001:2000, ec certificate93/42/eec, programmable treadmill running machine with user terminal (display &keyboard) stand- alone and remote control via rs232 running surface: l:170 cm (minimum), w: 65 cm (minimum) maximum possible load: 200 kg (440 lbs) speed range: 0-40 km/h elevation: 25% (14 maximum elevation) motorized adjustment, reverse belt rotation. motor system 3.3 kw, single phase ac motor, maintenance free and brushless power transmission: frequency inverter, poly v- belt, very quiet operation safety system: emergency-off safety stop switch (safety lanyard with actuator, pull cord and clip); potential equalization bolt; transformer for potential-isolation from the mains ambient condition: temperature: +10to +40 degrees c, humidity 30 to 70% display (resolution): lcd display heartrate monitoring: wireless transmitter; the treadmill should be able to interface with well-known compatible metabolic gas analyzer as per standard and custom exercise protocols different programs safety harness-1. indispensable accessory for stress testing, accident prevention and for the general safety of athletes.2. safety arch with different heights and widths to fit all running machines.3. an emergency stop at the crossbar of the safety arch allows automatic stop of the running belt in the moment a fall occurs.4. the harness and chest belt (available in 5 sizes: xxs, s, m, l, xl) secure the subject and prevents falling over to the front.5. chest belt straps do not pinch or restrict the athlete", programmable ergometer functional design and excellent stability, load up to 160kg. easy to use saddle, handle bar and pedals speed independent and dependent power control handle bars are easy to change to suit different tests, rotatable by 360 degrees. mechanical/motor-assisted seat a
Tender For supply of consumables for laboratory : - bottom connector for ea 18x2x1 mm , valco bulkhead connector , bush ceramic id 2.1 lg 3 , capillary fused silica 0.18_0.27 , ceramics column , spacer ring , spacer 24.8 x 21 x 1 ceramic , spacer 24 8 x 21 x 2 quartz , spacer 24.8 x 21 x 4 quartz , spacer tube od5x3.2x1.5l , capillary.fused silica id 0.32 , gasket fibre 8 x 5 , slit-0.2 source tantal , compressed air service unit , measurement needle gas bench , membrane complete , microspatula , nafion tubing f. gas dryer , pressure spring , connector m5 for tube , seal type 292.3406 , set dichtungsringe
Tender For corrigendum : providing of facility management services - lumpsum based - chirimiri area; hydro testing of one bomb combustion vessel for bomb calorimeter model:6200,make: parr instrument company, installed at central coal & gas laboratory, secl chirmiri area; consumables to b..
Tender For item wise procurement and supply of laboratory items for a period of 12 months - equipments, digital turbidity meter/ nephelometer -(a).parameter range- 0 to 200 & 200 to 1000 ntu*. (b). readability - 0.1 ntu & 1.0 ntu. ( c). accuracy - 3% of range. (d). repeatability - 2% of range. (e). light source - tungsten halogen lamp. (f). detector - photo diode. (g). data presentation - 31/2 digit 7 segment led of 12.7 mm height. (h). accessories - matched test tubes- 5 nos. (i). useful for determination of sulphate, phosphate, chloride, zn, ag, etc. by astm procedure. (j). extendable for measurement of inhibition growth of semantic microbial agent .brands-systronic,techlab,elko, digital conductivity meter with conductivity cell type cc-03b. (a). conductivity range : 0 to 20,200 m s*, to 2,20 & 200 m s*, (b) readability : 0.05% of range, (c) accuracy ; +_1% of range, (d) repeatability;+_1% of range, (e) data presentation: 31/2 digit 7 segment led of 12.7 mm height, (f) operating frequency: 1000hz, (g) temp. compensation: 0 to 500 c manual, (h) cell constant: 0.05, 0.1 or 1.0 (selectable), (i) out put: 20mv full scale into 10kz resistive impedance, (j) accessories: cell stand with cell holding clip.brands-systronic,techlab,elko, digital ph meter with combined ph electrode type cl - 51b (a). ph range: 0 to 14, +_1999 emf (mv), (b) readability : 0.1 ph, 1emf(mv), (c) accuracy ; +_0.01 ph, +_1 emf (mv), (d) repeatability;+_0.01 ph, +_1 emf, (e) temp. compensation: 0 to 1000 c manual, (f) data presentation: 31/2 digit 7 segment led of 12.7 mm height with polarity, (g) accessories: stand with electrode holding clamp, buffer tablets and polythine bottle, (h) physical dimensions: size 295 x 165 x 140 & weight - approximate 3, (i) manual 2 point calibration for ph, digital salinity meter (micro processor based water analyzer with magnetic stirrer), (a) measures directly ph, emf, temperature, electrolyte conductivity(ec), total dissolved solid (tds), dissolve oxygen (do), sanitary colorimeter (abs & %t) and turbidity in water sample one at a time. (b) data presentation: 2 lines 16 character dot matrix lcd modules, (c) light weight portable and easy to carry on field, (d) operates on rechargeable battery & mains supply, (e) ph: range- 0-14, readability- 0.001, accuracy - +_0.001,repeatability - +_0.1, (f) emf (mv): range- +_1999,9, readability - 0.1, accuracy - +_0.1, repeatability- +_0.1, (g) temp: range - 0-1000 c, readability - +_0.1, accuracy - +_0.5, repeatability - +_0.1, (h) ec; : range - 0-200 ms (5 ranges), readability - 0.05% of range, accuracy - +_0.1 of range, repeatability - +_0.5% of range, (i) tds: range- 0 to 100 ppt 5 range with pds factor 0.5, readability - +_0.05% of range, accuracy - +_1% of range, repeatability - +_0.5% of range, (j) do: range - 0-20, readability - 0.1, accuracy - +_0.1, repeatability - +_0.1 (k) colorimeter: range- +_2 abs & 0 to 100% t, readability - 0.001, accuracy - +_0.05 abs, repeatability - +_0.01 abs, (l) turbidity: range - 0 to 100 ntu, readability - 0.001, accuracy - +_2%, repeatability - +_0.1% (m) salinity ranger: 0 to 40 ppt, accuracy - +_1%, temp, compensation - 0 to 500c, sensor- ise (chloride) & re- bnc, (n) accessories: ce, dip type conductivity cell of 1.0 cell constant, do probe, thermo probe, magnetic stirrer, mains operated electromagnetic stirrer gi 631, stirring capsules, electrode stand with holding clamp, gas permeable membranes and 10mm & 30mm test tubes., zerological water bath superior quality(manufactures specification should be uploaded), ph meter (pocket type), brands-tamp,techlab,scientix, tds meter (pocket type) ,brands-tamp,techlab,scientix, magnetic stirrer superior quality (manufactures specification should be uploaded), heating mantle superior quality (manufactures specification should be uploaded), rainguage with measuring cylinder superior quality (manufactures specification should be uploaded), water purifier (dew drops)superior quali