Tender For supply of material code: w90311928870 unit oil purification system for singrauli project , material code: w90311928889 oil purification system (central) for singrauli project , material code: w90318103427 seperator motor for lub oil purifier , material code: w90318103168 rtds for oil purification unit: 1 no. each type and range , material code: w90318103150 pressure switch for oil purification unit: 1 no. each type and range , material code: w90318103265 mandatory spare for dps across polishing filter of oil purifier unit , material code: w90318103192 level switch for oil purification unit: 1 no. of each type and range , material code: w90318103176 pressure indicators for oil purification unit: 1 no. each type and range , material code: w90318103184 temp indicator for oil purification unit: 1 no of each type and range , material code: w90318103290 mandatory spares for flow switch of oil purifier unit, , supervision of erection & commissioning lump sum per man day charges at site, including every expens , supervision of erection & commissioning lump sum per visit charges (to & fro) including travelling t , performance test of particle size of impurities for lube oil (iso vg-46) as mentioned in sl. no. 5(a)
Tender For supply of w90414906853 drg: 31493201323 var00 rev: 02 magnetic level indicator as per dwg no. - 31493201323 var0 , w96415303295 drg: 31493201323 var 02 rev: 02 magnetic level indicator as per drg no. 31493201323 var
Tender For supply, installation and commissioning of iot based water level indicator in 100 coaches (73 under slung & 27 overhead) of 04 rakes of coaching depot/puri & bbs as per annexure-a. the items consis ts of (i) hydrostatic pr. water level sensor for 100 nos. of coaches. qty- 127 nos.(ii) water level transmitter based on lorawan(01 no. for each coach) for 100 nos. of coaches. qty- 100 nos(iii) multi channel outdoor gateway with 3g/4g for lorawan with location system- 03 nos. for 01 rake-qty-12 nos. [ warranty perio d: 30 months after the date of delivery ]
Tender For additional ldindori industrial area m and r to wss at addl dindori ia talegaon akrale providing and fixing of micro processor based digital wireless level indicator water monitoring system and allied works at wtp akrale
Tender For supply of outdoor plinth mounted distribution transformer of rating 500 kva, 3-phase, 50hz , oil immersed, non-sealed type (transformer tank body and cover are bolted), primary winding in delta a nd secondary winding in star (vector symbol dyn11), onan cooled transformer, conforming to is 1180 (p art 1):2014 with amendment nos. 1,2,3,4 or latest, and supplied with all standard fittings mentioned in cla use 20.1 of is 1180 (par1) latest with condition that drain-cum sampling valve will be applicable for all cap acity of transformers. oil temperature indicator & winding temperature indicators (for transformers above 200kva) will be provided as per clause 20.2 f) of is 1180 (part 1). terminal arrangement: the transformers shall be fitted on high voltage and low voltage sides with outdoor type bushings of appropriate voltage and current ratings. the high voltage bushings (3 nos.) shall conform to is/ iec 60137.the low voltage bushings (4 nos.) shall conform to is 7421. suitable cable-end box along with cable entry hole glands is to be provid ed as follows: a) for outdoor type: l.t. side b) for indoor type: h.t. side & l.t. side. along with following de tails: (i) kva rating of required transformer: 500kva (ii) no load voltage ratio: 6kv/415v-240v (iii) type o f mounting: plinth: (iv) the type of tap changer: off- circuit tap changer for variation of hv voltage from + 5% to -10% in steps of 2.5% (v) outdoor type (vi) energy efficiency level (latest)- 3 or higher. [ warranty p eriod: 30 months after the date of delivery ]
Tender For supply of outdoor type , plinth mounted, distribution transformer, minimum energy efficienc y level 3 of rating 500kva,3-phase, 11kv/415-240v, 50hz, oil immersed, non- sealed type (transformer ta nk body and cover are bolted), copper wound, primary winding in delta and secondary winding in star (ve ctor symbol- dyn11), onan cooled transformer, conforming to is 1180 (part1):2014 with amendment nos. 1,2,3,4 or latest, and supplied with all standard fittings mentioned in clause 20.1 of is 1180 (part 1) latest with condition that drain-cum-sampling valve. oil temperature indicator & winding temperature indicators will be provided as per clause 20.2 f) of is 1180 (part 1 terminal arrangement: the transformers shall be fi tted on high voltage and low voltage sides bushing appropriate voltage and current ratings., low voltage si de cable end box required. the high voltage bushings (3nos.) shall conform to is/iec 60137. the low voltag e bushings (4 nos.) shall conform to is 7421. off-circuit tap changer (applicable for all ratings above 200 k va) for variation of hv voltage from +5% to -10% in steps of 2.5%. [ warranty period: 30 months after th e date of delivery ]