Get complete information related to latest Metal Cover Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Metal Cover Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Metal Cover Tenders.
Tender For supply of switching disconnecting fuse (sdf) 2 pole 315a, 415v insulation suitable for 690v with 315a 415 v breaking capacity minimum 100ka rating fuse and metallic cover.as per rdso modification sheet no. rdso/pe/ms/ac/0086-2022 (rev.0). item contains the following material -one number switch disconnector & two number fuse and approx. maximum size- (l=450mm,w-350mm,&h=300mm) make- l&t{part no-ck9!0070009(switch disconnector &fuse with encloser), sf94234(fuse)}, siemens{part no-3kx8345-4ac(encloser),3kl8331-2ua00(switch disconnector &fuse with encloser),3na33520rc(fuse)}, abb & schneider. bidder should provide oem authorization or dealership certificate or proof of purchase from oem or oem authorized vendor along with supply. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For annual rate contract for supply and installation of electrical items and services at padc, panipat - electrical arc padc panipat 1st year, excavation of earth for cable / pipe laying for electrical work excavation of earth for cable trenches / laying of g.i. pipes for cable work in all types of soils including saturated soil upto a max. depth of 1.5 metres including shoring, strutting and bailing out of water (if necessary), backfilling and compacting in layers not exceeding 20 cm. thick to the finished ground level and disposal and dressing of excess earth within a lead of 50 metres all complete with labour and materials as per standards, drawings, specifications and directions of engineer-in-charge., 200 mm x 25 mm x 2 mm, supplying and fixing of gi route marker suppplying cable route marker with 10 cm x 10 cm x 5 mm thick gi plate with inscription thereon, bolted/ welded to 35 mm x 35 mm x 6 mm angle iron, 60cm long and fixing the same in ground as required. job includes painting with one coat of redoxide and finishing paint., 3 / 3.5 / 4 x 25 sqmm, 3 / 3.5 / 4 x 50 sqmm, 1.5 sqmm, 2.5 sqmm, 4 sqmm, 6 sqmm, 10 sqmm, 16 sqmm, 20 sqmm, 25 sqmm, 35 sqmm, 16 sqmm, 25 sqmm, 35 sqmm, 50 sqmm, 10.0 to 16.0 mm, 16 sq. mm, 65 mm dia 3 metre long, 25 x 5 mm gi strip, 64 kg charcoal and 5 kg salt, 100 amps., 63 a tpn 4 way, 5 to 32 amp, 40 amp, double pole, triple pole, triple pole and netural, four pole, 16 amps., 30 ma, 63 amps., 30 ma, 63 amps., 30 ma, 10 a spn. mcb industrial socket outlet supplying and fixing 10 amps., 240volts, spn industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 10 amps. c curve, sp,mcb, in sheet steel enclosure, on surface or in recess, with chained metalcover for the socket outlet, and complete with connections, testing and commissioning etc. as required. note: isi marked sockets shall be used., 20 a spn. mcb industrial socket outlet supplying and fixing 20 amps., 240volts, spn industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps, c curve, sp,mcb, in sheet steel enclosure, on surface or in recess, with chained metalcover for the socket outlet, and complete with connections, testing and commissioning etc. as required. note: isi marked sockets shall be used., 20 a tpn mcb industrial socket outlet supplying and fixing 20 amps., tpn, industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 amps, c curve, tp mcb, in sheet steel enclosure, on surface or in recess, with chained metalcover for the socket outlet, and complete with connections, testing and commissioning etc. as required. note: isi marked sockets shall be used., 2 + 4 way, provide shock hazard chart supply and installation of shock hazard chart as per ie rules 1956 (clause-44) complete with frame and glass including necessary clamps, bolts, rawl plugs, etc. breachking and making good the wall if required. all complete with labour and materials as per the direction of engineer-in-charge., provide caution board at sub-station supply and installation of "caution boards" mv-200 mm x 150 mm / hv- 250 mm x 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.at sub-stations as per is2551/upto date including supply of necessary clamps, nuts, bolts and other hardware. all complete with labour and materials as per the direction of the engineer-in-charge, upto 5.5kw, plug- 2 pole+ earth, 250v- 20 amp, plug- 3 pole+ earth, 440v- 20 amp, red / yellow / amber / green / milky white leds, blue led, 1 way 5 / 6 amps. piano type switch with isi mark, 1 way 15 / 16 amps. piano type switch with isi mark, 2 pins 5 / 6 amps. penta flush socket outlet, 3 pins 5 / 6 amps. penta flush socket outlet, piano type 5 pins 5 / 6 amps. socket outlet, 3 pins flush type 15 / 16 amps. socket outlet, flush type 6 pins 6 / 16 amps. uni. socket outlet with isi mark,
Tender For supply of led marker light cum tail light for memu application conforming to rdso specn no.elrs/spec/pr/0022 (rev.1 october-04) suitable for use in system voltage type 'e' of clause 2.2.2 note:1. rdso/clw approved sources only be considered. one unit consists of 01 no. red light, 01 no. white light and 01 no. metallic cover frame [ warranty period: 24 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted:max 8 lacs ] ]
Tender For purchase of eee equipments for power system laboratory - purchase of eee equipments, pt trainer kit* variable ac voltage source of 0-220vac & variable ac current source of 0-25a consists automatic trip timer by dspic33ch controller* autotransformer for voltage/current adjustment with mcb protection* test current transformer 25/5a test voltage transformer (pt) 220/110v ac* all to be mounted on a panel with diagram engraved stickered front panel with digital ac voltmeter & ammeterprovision for measuring ratio error of ct & pt, ct trainer kit* variable ac voltage source of 0-220vac & variable ac current source of 0-25a consists automatic trip timer by dspic33ch controller* autotransformer for voltage/current adjustment with mcb protection* test current transformer 25/5a test voltage transformer (pt) 220/110v ac* all to be mounted on a panel with diagram engraved stickered front panel with digital ac voltmeter & ammeterprovision for measuring ratio error of ct & pt, insulator string trainer kittypically custom lab demo kit for high-voltage insulator strings; specs vary (mechanical + electrical stress testing), isolation transformer230v ac, 3kva single phase isolation transformer with suitable metalcovering, banana connection and rolling arrangements
Tender For supply of 24 volt power supply unit for ptz camera , splicing box , 5 amp power supply unit for nvr , ptz camera , 5mp ip camera , metallic cover for cameras with bird proofing , network video recorder 32 channel , 10 tb hard disk , 2 core 10mm copper electric wire , 12u rack , 3u rack , 65 inch led display , power point switch board with mcb
Tender For supply of oil filter , air filter , fuel filter , air filter element , fuel water seprator , assy master cyl , frt wiper motor , assy suction line , hose non metalic , cover assy clutch , cable assy speedometer , wiper motor assy
Tender For corrigendum : provision of isolation switch for starring battery in power car as per rdso modification sheet no. rdso/pe/ms/ac/0086-2022 (rev.0) or latest. the works includes supply, installation, testing and commissioning of isolation disconnector switch with fuse of approved make. list of material required in 1 set power cars (1 power car having 2 nos. d.a. set) in above modification :- 1. switch disconnecting fuse (sdf) 2 pole 315a 415v insulation suitable for 690 volt with 315a 415v breaking capacity minimum 100ka rating fuse and metallic cover, the switch disconnector of make l&t (ck910070009 ? sf94234), siemens (3kx8345-4ac-3kl8331-2ua00-3na33520rc), abb or schneider or similar - 02 nos. 2. copper cable 120sq.mm. as per rdso specification no. elrs/ spec/elc/0019. (rev.-1) - 32 mtr. 3. fuse link sf 94234 315a ? 04 nos. 4. conduit as per rdso specification - rdso/pe/spec/ac-0138 2009 (rev 1) for 120 sq.mm. copper cable (nw-29) - 32 mtr. 5. gland - 04 nos. 6. control cable length - 50 mtr. [ warranty period: 30 months after the date of delivery ]