Tender For repair/maintenance of various capacity lt switch gear i.e mccbs, acbs, contactor, apfc panels, all type of acs and other miscellaneous work at af stn dadri under aor of ge (af) faridabad
Tender For repair/replacement of various capacity lt switch gear i.e mccbs, acbs, contactor, apfc panels, all type of acs and other miscellaneous work at af stn chandinagar under aor of ge (af) faridabad
Tender For repair/maintenance of various capacity lt switch gears i.e. mccbs, acbs, contactor, apfc panels, acs, dg sets, amf panels and other e/m works at af stn mcc basant nagar under aor of ge (af) faridabad
Tender For repair/ maint of borewell redevelopping, switch gear dol starter, three phase starter, contactor, motor rewinding, pumps, centrifugal pump under zone 1c area under age em i and repairs / renewal of lt oh line, lt ug cable, lt panel, street lights and
Tender For supplying electrical materials and repair maintenance services for divabatti at awasari bk tal ambegaon dist pune - supplying and erecting modulartype switch6a/10a, supplying and erecting street light bracket for erection ofsingle fitting made from 40 mm. dia b class g.i. pipe 1.0 m in length, providing cement concrete foundation including excavationfor the poles 60cm * 60cm * 1.5m deep in 1:3:6 cement concrete ( 20 * 25 mm stone metal) and 45cm * 45cm * 45cm / 45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner. (for 8.5 to 9 m poles) (16-3-2), supplying and erecting steel tubular swaged pole 139.7 * 114.3x 88.9 mm. dia with 4.5 * 3.65 * 3.25 mm thickness ( 4.5 + 1.75 +| 1.75m) length respectively and total 8 m long with pole cap, base plate in provided foundation. (weight 101 kg.) as per specification no.oh-pl/stp, supplying and erecting street light bracket made from 25mm. dia bclass g.i. pipe, 0.6m. in, supplying and erecting led street light fitting suitable for 36w to 40w led street light, including lamp, with pf > 0.95 class ip 65., supplying and erecting led street light fitting suitable for 50w lamp, including lamp, with pf > 0.95 class ip 65., supplying and erecting led street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65., supplying and erecting led street light fitting suitable for 90 w led street light, including lamp, with pf > 0.95 class ip 65., supplying and erecting led flood light fitting of 120w, including lamp, with pf > 0.95, class ip 65, supplying and erecting led flood light fitting of 150w, including lamp, with pf > 0.95, class ip 65, providing rental basis hydraulic bucket vehicle of hight 13 mtr. and weight capacity 200 kg. with driver, oprator and disel etc. for per day basis, labour chrages for led fitting on street light or ms light pole., dismentaling charges -led street light of pole., 1.25 mm crca sheet metal enclosures box for timmer and mcb, supplying pvc insulated pvc round sheathed 1.5 sq.mm, supplying & laying armoured cable 4c x 6 sq.mm., supplying & laying armoured cable 4c x10 sq mm, supplying & laying armoured cable 2c x 10 sq mm, supplying & laying armoured cable 4c x 16 sq mm, supplying, erecting & marking spmcb 6a to 32a, b- series (for lighting) 5-3-3, supplying, erecting & marking dpmcb 6 a to 32 a bseries (for lighting) 5-3-7, supplying and erecting programmable digital almanactimer microcontroller based with real time clock to operate on derived switching "on" & switching "off" street light as per daily sunset and sunrise respectively, supplying & erecting crimping type aluminium lugs for cable upto 16 sq mm complete, supplying & erecting crimping type coper lugs for cable upto 1.5 to 6sq mm complete..., supplying and erecting two pole power contactor 250v 32a for time switch complete erected on wooden block/provided box, with necessary materials. 4-4-3, supplying & erecting mains with2x1.5 sq.mm f.r copperpvc insulated wire laid in provided conduit/trunking/inside pole., supplying and erecting mains with isi mark wp2 x 6 sq. mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire no. 8 swg 1-4-3, supplying and erecting mains with isi mark wp2 x 2.5 sq mm.1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire, supplying and erecting mains with isi mark wp2 x 10.00 sq mm. 1100 v. grade aluminium pvc insulated pvc sheathed wires on g.i. bearer wire, 25 amp, 32 amp three phase l/t contactor, 2.5 sq. mm multistand copper wire, insulation tape, water proof tape, street light pole box frp, cement street light pole clamp, m.s. street light pole clamp, led street light arm bend pipe, small size frp box for mcb, big size frp box for mcb, supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (dwc) of hdpe for enclosing cable below grou
Tender For corrigendum : supply of ems repair at bsnl tele bhavan ahmedabad f f - replace 4 ft 36 w t rod , replace 4 ft 18w led , replace 4 ft 230 v tl starter , replace electronic choke for tl , replace side holder for tl , replace 5 amp piano switch , replace 15 amp piano switch , replace 5 amp modular switch , replace 15 amp modular switch , replace 5 amp socket outlet 3pin , replace 15amp socket outlet 3pin , replace 5 amp modular outlet 3pin , replace 15 amp modular outlet , replace 2 module electronic regulator , replace 9w led lamp , rewinding 0.5hp monoblock pump , rewinding 10 hp monoblock pump , pvdg skilled technician , wiringfor l powerwith4sqmm cu , wiring with1.5qmmfrlscuwire , wiringwith4.0sqmmfrlscuwire , sdrg 1no 1.5 sq.mm frls cu wire , s drg 2no 1.5 sq.mm frls cu wire , sdrg 2no 4.0 sq.mm frls cu wire , sf 20mm pvc conduit , sl 2c 6 sq mm xlpe al cable , sl 4c 10 sq mm xlpe al cable , laying cable upto 35sqmm , laying cable 35to95sqmm , laying cable 95sqmm to 185sqmm , endtermi2c6.0sqmm cable , endtermi4c10sqmm cable , endtermi3.5c35sqmm cable , sf 32atpn mcb , sf 40atpn mcb , sf 63atpn mcb , sf 5 to 32a sp mcb , sf 5 to 32a spn mcb , sf 40a dp rccb spn , sf 40a 4p rccb tpn , sf 63a 4p rccb tpn , repalce sreet light with 25 w led in holder , repalce sreet light 25 w led on pole , repalce pvc box , replace heat detector fda system , replace smoke detector fda system , replace mcp fda system , replace ri fda system , replace ri of sounder fda system , refill fire extgshr 4.5kgs , pvdg hosepipe for fire extgshr 4.5kgs , sf 12v 26ah battery fda system , rpair card of fda panel , repair hooter of fda system , repair mcp of fda system , repair ri of fda system , repair pa amplifier of fda system , repair mike of pa fda system , conduct fire drill for bldg , serice 11kv 400a id substation , filteration mineral oil , servicing mv and lt panels incl all , calibartion relays by inj method , replacement 2a hrc fuselink , replacement 63a hrc fuselink , replacement 125a hrc fuselink , replacement 200a hrc fuselink , service of dg set 250 kva , service radiator for ea set 250 kva , supply smps battery charger 10a , sf 12v 130ah battery for ea set , supply brass battery terminals , sf led indi lamps 220 v ac , sfixing bradided fuel pipe for ea , replace blower motor for sac unit , replace blower drum for sac unit , replace condenser motor for sac unit , replace condenser blade for sac unit , replace pcb for ac indoor unit , replace pcb for ac outdoor unit , replace rotary compressor for sac unit , replace 25to35 5 mdf capacitor for ac , replace 25a 2p contactor for ac , replace term box for ac , water service for ac unit , blower service for ac unit , leak test and r22 r 410 gas charge for ac unit , replace 50mm thick filter , sf micro controller for ac unit , replace 25a spn mcb , site visit for ac repair
Tender For corrigendum : supply of ems service te railwaypura - pvdg reneted oump for use , replace 50mm gi b class pipe , sf 3inch half turn valve gi , sf 2inch half turn valve gi , modify 3inch water line by pvdg 3inch flange , modify 3inch water line by pvdg 3inch nipple , modify 3inch water line by pvdg 3 inch tee , modify 3inch water line by pvdg 2.5 inch nipple , modify 3inch water line by pvdg 3 and 2.5 inch socket , modify 3inch water line by pvdg 2.5inch coupler , modify 3inch water line by pvdg 2 inch nipple , modify 3inch water line by pvdg 2 inch tee , sf 50 mm nrv , plumbing work for priming assembly , arrangement of automationof extg water supply by pvdg 5 hp dol starter , arrangement of automationof extg water supply by pvdg 63a 4p changeover mcb , arrangement of automationof extg water supply by pvdg auto timer 24 hrs , arrangement of automationof extg water supply by pvdg wlc , arrangement of automationof extg water supply by pvdg 63a 4p mcb , arrangement of automationof extg water supply by pvdg 3.5c 50 sq mm et , arrangement of automationof extg water supply by pvdg 200 a terminal , sitc 10kvar app capacitor , rewind ex fan ped fan motor upto 200w , rewind ceiling fan motor upto 1400 mm , replace 4 ft 36 w t rod , replace 4 ft 18w led , replace 4 ft 230 v tl starter , replace electronic choke for tl , replace side holder for tl , replace 5 amp piano switch , sdrg 1no 1.5 sq.mm frls cu wire , s drg 2no 1.5 sq.mm frls cu wire , replace 2 module electronic regulator , refill fire extgshr 4.5kgs , pvdg hosepipe for fire extgshr 4.5kgs , sf 12v 26ah battery fda system , conduct fire drill for bldg g plus 3 flr , service 11kv substation with ht panels , repair of substation panel by repacing led ind lamps 220v , repair of substation panel by repacing 2 to 4 a hrc fuse , repair of substation panel by repacing lml1 contactor kit , repair of substation panel by repacing bimettalic ol for blower mn2 , repair of substation panel by repacing spp ol relay mpr1 , repair of substation panel by repacing 8 pin 220v pla relay , repair of substation panel by repacing 0 to 400a ammeter ac , repair of substation panel by repacing 0 to 30 a ammeter ac , repair of substation panel by repacing 0 to 500v voltmeter ac , repair of substation panel by repacing dc ammeter 96mm , repair of substation panel by repacingdc voltmeter 96mm , repair of substation panel by repacing selector switch , b check service of dg set 320 kva , supply smps battery charger 24v 10a , sf 12v 130ah mf battery for ea set , supply brass battery terminals , pvdg led ind lamps 220v ea set , sfixing bradided fuel pipe for ea
Tender For re babbiting-dismantling of bearings and pads from housing,rebabbiting of 10 nos tgb thrust pad along with all accessories,rebabbiting of turbine guide bearing, mid bearing & end bearing along with floating seals and all accessories,material composite test, ut test and dp test should be done for re-babbitted material,assembly of re-babbited bearings with blue match,submitting the video graphs of re-babbiting and reports of re-babbiting.re-alignment-the reason for shifting of generator shaft by 2 to 3 mm shall be analyzed and rectification works needs to be carried out,complete dismantling, assembling, painting and re-alignment of machine shaft,inspection of turbine shaft journal surface and repairs if required,inspection/replacement of worn out bushes and seals of guide vane, if necessary,inspection and repair of labyrinth ring, face plates, guide vanes and runner,guide vanes bed setting,tgb water cooler descaling work to improve the efficiency of cooler,complete assembly of machine,checking the magnetic axis of the generator and to ensure its alignment, checking of the unit leveling at all places and complete alignment of machine shaft,testing & commissioning of complete machine,painting of entire machine,checking of vibration & site balancing of machine,submission of vibration, balancing & alignment reports.flow switch-supply and installation of flow switch (flow rate110 lpm) along with 01 no 01 nc contact for inlet and outlet lubrication oil pipelines,supply and installation of pressure switch (30bar) for inlet and outlet lubrication oil pipelines,supply and installation of level switch for in tgb oil sump.replacement of new miv trunion shaft-dismantling of miv counter weight, miv servomotor assembly, and other related parts,lifting of miv from the bed,transportation of miv to the firms place, if required,replacing old nitrile rubber trunnion seals with existing profile by new one on both sides,replacements of miv trunnion shaft. providing of necessary drawings,material composite test, ut test and dp test should be done for new trunnion shaft & trunnion seals, bushes etc,all related fasteners and dowel pin to be replacing by new one,drive and non drive end trunnion bush, cupseals, stop end plate, washer ring etc need to be replacing by new one,repair of miv discand main body to be attended, if required,supply and replacement of miv disc rubber seal,pressure testing and commissioning should be carried out as per standard in presence of kpcl engineers,all tools & tackles required for the above mentioned works shall be arranged by contactor only.