Tender For procurement of spares for an-32 aircraft - strut, squib control head, control box, triple troop seat, angular velocity trans, em valve,solenoid-operated, radome installation, pilot's seat, ics panel, positive lead of stg-12tmo-1000 starter generator, control rod, dampers, connector, movable rail, lh, tail cone rh, shackle, rear navigation light, energency breaking handle (rh), safety harness restraint mechanism for aircrew seat, safety harness restraint mechanism, three piece seat(portframe 22 to 25), adapter, radome, end fitting, metal pipe, jb of light container, spare fuse box, over voltage protection unit, voltmeter (0-50v), ramp drive reduction gear, ramp lifting cylinder rh, removable container floor, rh, main landing gear forward doors lock (rh), panel with units used for suction pipeline pumping through, panel with flap control units (0101 through 0207), cargo hatch ramp control panel, control (switch) panel {cargo compartment}, panel, lh, generator control unit, frequency cutoff box, digital voltage regulator, eletric motor, windshield wiper components, pilot seat, limiter (rh), air intake 0101 through 0110 ), cargo door control panel, rh 463v pump filter, servo unit, over voltage protection unit, elevator, left, aileron inboard section, lh, door in partition at frame 7, limit switch mechanism, dim instruments jb, control unit, hf signal generator, aileron outboard section, lh, lock cylinder
Tender For supply of laryngeal mask airway, size 2.5, 3, 4, 5specification:1. it should be a 2nd generation supraglottic airway device.(lma)2. it should be anatomically curved for rapid placement & long-term performance.3. it should be designed to reduce dead space by up to 39%.4. the thin cuff should maintain high seal pressure of up to 40 cmh20.5. it should provide maximum intra-cuff pressure of up to 60 cmh20.6. it should have integrated gastric access channel for managing gastric content.7. it should allow placement of maximum 16 fr of gastric tube through the channel.8. it should have intubation capability using standard et-tubes.9. it should allow placement of maximum 8.0 et tube through the airway.10. should have integrated bite absorption area to prevent airway occlusion.11. cuff and airway tube should be moulded as a single unit for safety %u2013 no separation.12. it should have navigation marks for guiding flexible scope during intubation.13. the pilot balloon should provide mask size & tactile indication of degree of inflation.14. it should have 15 mm (iso- international standard) airway connector.15. it should be made of 100% phthalate free & latex free medical graded material.16. it should be mr safe.17. it should be disposable, eliminating chances of cross contamination.18. should be available in all standard sizes 3(30-50kg), 4 (50-70kg), 5(70-100kg) to accommodate specific age group of patients.19. should be us fda, iso certified for quality assurance20. size 3 -2, size 4 -4, size 5-421. brochure to be uploaded with the offer.
Tender For tender for supply of clip on type terminal station , auto change over switch 250a , cam type single pole on-off switch 10amps , 1s160 , triple pole moulded case circuit breaker 100amps , hcos 100a for emergency operation(ex.)if envisaged in sotr , illuminated push button green , cam type selector switch 2p 2 way with off 10a , hrc fuse link rated 100a , fuse link 2amps , helo starting cable with nato end connectors (21 meters) , mccb 630a , type lm 630b , make e , 3 pole mccb 32a -nsx100f , mcb 250a with micrologic 2.2 trip unit(lv431770) , tp mccb rated 50a , single pole nine way without off rotary switch rated 16a , contactor 110a t.p.(contact kit) , aux contact.base block ( 1 no+1nc) for 110-a t.p. , fuse 32a fitting hrc , unshourded pushbutton 1no+1nc with yellow colour lens(pmt1ab , illuminated pushbutton integral led 230v red , add on 1no contact , d.p miniature circuit breaker rated 16a , terminal , conventional fire detection panel 4 zones , on delay electronic timer ac 110-240v having range 1-30s , 230v ac relays 4 c/o with led and base alonwith clamp , tp mcb 63a(c60h 3p 63a c) , ammeter 0-1000a , rm-800a , ctr 1000/5a , 96x96 cl1 acc 900 scale , hrc fuse fittings rated 20a (3nw20nnsf) , hrc fuse link rated 6a(3nwns6) , hrc fuse fitting rated 20a (3nwns10) , insulation monitoring relay 115v 3ph 400hz (vtv-02) , ammeter 0-200a ctr 200-5a , 400hz acc cl-1 , 96x96 rm at 150a , kilowatt meter 120-0-750 kw size 96x96mm , frequency meter 55-60-65hz 440v , size 96x96mm rm at 60hz , 1 watt , 24v dc/ac , led bulb , milky white of e27 thread type , 1 watt , 230v ac , led bulb , milky white , of e27 thread type. , breaker 25a , dp mcb , step down transformer 20kva , 380 230v , 3ph , 50 hz star-delta , smoke detector tester gas bottle - solo , main processor unit , navigation lamp 65w 230v (per yard) , under voltage coil 230 , 50/60 hz , hrc fuse fitting with fuse link rated 4amps , hrc fuse fitting with fuse link rated 2a , 3 pole mccb , 100amps , 36ka , schinder make , phase sequence indicator 50-500v , 96x96mm cl1 acc 900 scale , kw mtr 15-0-150kw , ctr 2005/5a , rm at 80kw , 415v , 3p , 2 ele 96mm , generator protection unit415v , 3ph , 50hz , load sharing unit mv av 380v , 50hz , 3ph , ctr 250 5a , m340-discrete outputs-modicon m340 discrete dc output , indicating lamp integral led white colour , 24v ac/dc , indicating lamp integral led green colour , 24v ac/dc , indicating lamp integral led green colour 230v , contactor 800a dc , 28v coil with 1no/1nc aux. contact
Tender For supply of monitor - 26 widescreen _ 340 display 25. 5 lcd , naval client processor unit client server radar , radar control panel kit with i_o , pc i_o unit - standard compass , pcb assembly _scan converter 3 mil , 10. 4 multifunction display winmate ppc r10ik3s-vmt2hb , ip 66 enclosure for mfds , power adaptor , obd hanging head unit , obd navigation interface unit , obd connection unit , power supply , 1. band turning unit 25kw masthead add facilities - qty-4 2. x band 6ft 1. 8m antenna- qty-4 , s band turning unit 30kw masthead 220240v,50_60hz, 1 phase , antenna 12ft , scanner control unit