Web Analytics Made Easy - StatCounter

Meter Testing System Tenders

Get complete information related to latest Meter Testing System Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Meter Testing System Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Meter Testing System Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :40985789 Due date: 28 Jul, 202528 Jul, 2025 3.50 Crore
Tender For purchase of biomechanical lab - force platedimensions (w x d x h) in mm : 600 x 400 x up to 50 number of axes for force measurement: all 3 axes. x,y,z plate should be portable in naturesensor type: piezoelectricsampling frequency-(hz) =1000 hz or more force measured on each axis-fx,fy: 2,000 newton or more, fz: 10,000 newton or more hysteresis- (%fso): 0.5 linearity (%fso) 0.5 crosstalk (%) : 2water resistance rating: ip 50 or better.should be inclusive of installation.should be supplied with carrying case for 2 plates and noise free ups for on-ground assessment. the carrying case should be strong and sturdy.should be able to accommodate portable force plate 9286 ba, daq box 5695 and connecting cablesshould be able to protect the equipment from rain, impact and dust, should have rollers to move easilyshould be able to accommodate an ups also., isokinetic dynamometershould be able to access/test various joints in isolation should be able to meet requirements to test sports personsshould be able to test in different resistance modes such as isokinetic (concentric-concentric, concentric-eccentric ,eccentric, concentric ,and eccentric-eccentric), isotonic, isometric, and passive protocols should include options for angles, hold-times, rest period, repetitions, and sets. the system should be able to test all the major body segments and joints such as shoulder, forearm, elbow, wrist, hip, knee, and ankle.should have adjustable range of motion stops in full 360 degrees.should have 360-degree rotation for the force arm (connecting dynamometer to the pedal) to have wide range of motionshould be able to accommodate different athletes with varying height and weight with provision for seatbelt harness for better stabilitythe dynamometer or chair should be movable to accommodate different athletes for quick set-up and better usability with locking clamps for securing the system in place for testingshould be able to do gravity correction when the limbs are positioned with the lever arm on the dynamometerthe software should be provided to analyze the raw data and export the raw and processed data in different file formats such as excel, text, etc. the software should provide detailed report for various testing protocols such as individual test for joints, data/graph overlay for comparing pre and post testing, repeatability, progress, multi-session.should be provided with latest compatible workstation/laptop of reputed brand like hp, dell (latest generation) processor, minimum16gb ram, windows os 11, and laser printerconcentric speed: 500 deg/sec or more eccentric speed: 500 deg/sec or more concentric torque: 500 ft-lb (678nm) or more eccentric torque: 500 ft-lb (678 nm) or more isometric torque: 500 ft-lb (678 nm) or more isotonic torque: 500 ft-lb (678 nm) or more isotonic torque as low as .5 ft-lbfeedback formats: roadway, interactive line, interactive path, reaction training, proprioception training, breakout, and pong.torques. time, torques. angle, torque bars, work bars, power bars. it should be possible to use mechanical stops even with custom patterns (important for safety in research)the same attachment should be usable for left and right side of subject for consistencies in data.should be certified and approved by ce/eu medical devices directives or usfda, nord boardit should be portable and should have 2 load cell sensors per unit with easy to attach hooks pivoting 360 degrees joint improving sensor accuracy it should have knee position indicator for replication of test position in each time. should have sample rate per sensor: upto 400hz, capacity per sensor: 100 kg/980-1000n safe over load per sensor: 150kg/1500n, max over load per sensor: 200kg/ 2000n, resolution: 1n and sensitivity: 22.0+/-mv/v. should have rechargeable battery & battery life should be100 active hours approx. should have working temperature range 5-40 c. (all weather proof) latest upgradable software should have both wired & wireless connectivity connec

Central Government/Public Sector

CTN :41003356 Due date: 29 Jul, 202529 Jul, 2025 NA
Tender For supply of supply of bi directional elevated type high intensity runway edge light fitting clear clear as per boq , supply of bi directional elevated type high intensity runway edge light fitting clear yellow as per boq , supply of bi directional elevated type high intensity runway edge light fitting yellow red as per boq , supply of 150 watt, 6.6 amp, bi- pin halogen lamp for runway ama make runway edge type fitting. , supply of 105 watt, 6.6 amp, bi-pin halogen lamp for inset type fitting runway and sapl fitting , supply of bi-pin lamp holder suitable for 200w, 6.6a ama - aun edge light fixture , red filter suitable for ama make papi units. , supply of papi reflector for ama make papi unit. , supply of 8 inch taxiway omni-directional inset type edge light fitting , carrying out photometric test as per boq , calibration of ama make clinometer

Central Government / Public Sector

CTN :41001137 Due date: 22 Jul, 202522 Jul, 2025 NA
Tender For supply of 2 amps mv(milli volt) drop test unit. (a) current injection up to 2 amp ac. (b) current displa y range: 2 amp resolution 1 m amp. (c) millivolt display range: 200 millivolt resolution 0.1 millivolt. make: slazer or its equivalent. [ warranty period: 30 months after the date of delivery ]

Central Government / Public Sector

CTN :41000139 Due date: 06 Aug, 202506 Aug, 2025 NA
Tender For set of 02 cab ac items components consisting of (1) blower motor with double extended sha ft with fan impeller for air conditioning unit, frame 63, frequency-50hz +/- 5%, volts 415 +/- 10%, rpm: 13 60 with test certificate, as per rdso specification no. rdso/pe/spec/ac/0089, rev-0/ amendment no.1 or i ts latest- 05 nos. (2) condenser motor 0.15kw, frequency-50hz, frame 63, supply 415v ac +/- 10%, 0.7 a mps rpm: 1350, star connection, reference is: 325- 05 nos. for roof mounted packaged ac unit electric lo cos. note: (1) test certificate should be provided by firm along with the material. (2) the firms with past pe rformance of the tendered/same items subject to submission of proof of documents such as pos/r note are only eligible [ warranty period: 30 months after the date of delivery ]

Central Government And Public Sector

CTN :40702670 Due date: 16 Jul, 202516 Jul, 2025 5.14 Lacs
Tender For corrigendum : supply of ems repair at bsnl tele bhavan ahmedabad f f - replace 4 ft 36 w t rod , replace 4 ft 18w led , replace 4 ft 230 v tl starter , replace electronic choke for tl , replace side holder for tl , replace 5 amp piano switch , replace 15 amp piano switch , replace 5 amp modular switch , replace 15 amp modular switch , replace 5 amp socket outlet 3pin , replace 15amp socket outlet 3pin , replace 5 amp modular outlet 3pin , replace 15 amp modular outlet , replace 2 module electronic regulator , replace 9w led lamp , rewinding 0.5hp monoblock pump , rewinding 10 hp monoblock pump , pvdg skilled technician , wiringfor l powerwith4sqmm cu , wiring with1.5qmmfrlscuwire , wiringwith4.0sqmmfrlscuwire , sdrg 1no 1.5 sq.mm frls cu wire , s drg 2no 1.5 sq.mm frls cu wire , sdrg 2no 4.0 sq.mm frls cu wire , sf 20mm pvc conduit , sl 2c 6 sq mm xlpe al cable , sl 4c 10 sq mm xlpe al cable , laying cable upto 35sqmm , laying cable 35to95sqmm , laying cable 95sqmm to 185sqmm , endtermi2c6.0sqmm cable , endtermi4c10sqmm cable , endtermi3.5c35sqmm cable , sf 32atpn mcb , sf 40atpn mcb , sf 63atpn mcb , sf 5 to 32a sp mcb , sf 5 to 32a spn mcb , sf 40a dp rccb spn , sf 40a 4p rccb tpn , sf 63a 4p rccb tpn , repalce sreet light with 25 w led in holder , repalce sreet light 25 w led on pole , repalce pvc box , replace heat detector fda system , replace smoke detector fda system , replace mcp fda system , replace ri fda system , replace ri of sounder fda system , refill fire extgshr 4.5kgs , pvdg hosepipe for fire extgshr 4.5kgs , sf 12v 26ah battery fda system , rpair card of fda panel , repair hooter of fda system , repair mcp of fda system , repair ri of fda system , repair pa amplifier of fda system , repair mike of pa fda system , conduct fire drill for bldg , serice 11kv 400a id substation , filteration mineral oil , servicing mv and lt panels incl all , calibartion relays by inj method , replacement 2a hrc fuselink , replacement 63a hrc fuselink , replacement 125a hrc fuselink , replacement 200a hrc fuselink , service of dg set 250 kva , service radiator for ea set 250 kva , supply smps battery charger 10a , sf 12v 130ah battery for ea set , supply brass battery terminals , sf led indi lamps 220 v ac , sfixing bradided fuel pipe for ea , replace blower motor for sac unit , replace blower drum for sac unit , replace condenser motor for sac unit , replace condenser blade for sac unit , replace pcb for ac indoor unit , replace pcb for ac outdoor unit , replace rotary compressor for sac unit , replace 25to35 5 mdf capacitor for ac , replace 25a 2p contactor for ac , replace term box for ac , water service for ac unit , blower service for ac unit , leak test and r22 r 410 gas charge for ac unit , replace 50mm thick filter , sf micro controller for ac unit , replace 25a spn mcb , site visit for ac repair

Central Government/Public Sector

CTN :40994157 Due date: 09 Jul, 202509 Jul, 2025 NA
Tender For tender description : non-destructive test _ndt_ and semi-destructive test _sdt_ of concrete structures of equipment foundation of unit 2 and power house building structure of 3x105 mw units of tons hydel power station-1 at sirmour of madhya pradesh power generation corporation ltd _mppgcl_

CTN :40469350 Due date: 09 Jul, 202509 Jul, 2025 NA
Tender For bid to ras corrigendum : supply of valsartan 103mg tab , sodium chloride 0.65 percent w by v of 15 ml nasal drops , salmeterol 50mcg plus fluticasone propionate 250mcg seretide accuhaler 50 250 inhaler , salmeterol 50mcg plus fluticasone propionate 250mcg seroflow 250 rotacap , salmeterol 50mcg plus fluticasone propionate 500mcg accuhaler rotacap bott of 30 , chlorhexidine gluconate 2 percent in 70percent isopropyl alcohol 500 ml bott savlon lotion , saxagliptin 5 mg tab , selegiline 5 mg tab , semaglutide 3 mg tab , sertraline 25 mg tab , sertraline 50 mg tab , sevelamer 800 mg tab , sevelamer 400 mg tab , kits for estimation of sgot ast lab 5 x 20 ml erba , kits for estimation of sgpt alt lab , sildenafil citrate 50 mg tab , silodosin 4 mg plus dutasteroide 0.5 mg tab , silodosin 8 mg plus dutasteroide 0.5 mg tab , oint silver nitrate plus chlorhexidine oint , silymarin 70 mg tab , simvastatin 10mg tab , simvastatin 20 mg tab , sitagliptin 50 mg tab , sitagliptin 50 mg tab plus metformin 1000 mg tab , sod valproate 200 mg cr tab , sodium bicarbonate 1000 mg tab , sodium bicarbonate 500mg tab , sodium chloride 0.65 percent nasal drops , sodium valproate 300 mg cr tab , sodium valproate 500 mg tab , sodium valproate oral sol 200mg per 5ml bott of 100 ml syp , soft cervical collar size m , soft cervical collar size l , solifenacin 10 mg tab , solifenacin 5 mg tab , spirit lab , spironolactone 25 mg plus frusemide 20 mg tab , spironolactone 50 mg tab , sterile water for amp of 10ml injection , 2 propanol 45 gm 1 propanol 30 gm ethyl hexadecyl dimethyl ammonium ethyl sulphate 0.2 gm with skin protecting substances 500 ml bott with dispenser lotion , sulfasalazine 500 mg tab , sulphasalazine 1 gm tab , oint sunban spf 50 cream , knife bard parker blade size 1 fitting commercial no 12 packet of 6 , albendazole 10 ml syp , alpha amylase pepsin digestive enzyme syp , syp ambroxol 20mg per 5ml plus chlorpheniramine maleate in bracket 2mg per 5ml plus dextromethorphan hydrobromide 10mg per 5ml syp , syp amoxy 200 plus clavulanic acid 28.5 bott of 30 ml , azithromycin 200 mg per 5ml syp , cefixime 50 mg syp , cetrizine 5mg per 5ml bott of 60ml syp , cough expectorant 100 ml syp , iron plus folic acid syp , iron with vitamin b 12 and folic acid bottle of 200ml syp , essential amino acid tab , liver tonic liv 52 syp , mucaine gel oxetacaine 10mg per 5ml plus aluminium hydroxide 0.291gm per 5ml plus milk of magnesia 98mg per 5ml syp , paracetamol 162 mg plus ibuprofen 100 mg 60 ml syp , peractin cyproheptadine syp , salbutamol 100ml syp , syringe disposable plastic sterile 10 ml with needle , syringe dispo plastic 2ml with needle , syringe disposable plastic sterile 5 ml with needle , oint tacrolimus 0.1 percent eye ointment pack of 10 gm , tacrolimus 0.5 mg tab , tadalafil 10 mg tab , tadalafil 20 mg tab , tadalafil 5 mg tab , tamoxifen citrate 20 mg tab , tamsulin 0.4 mg plus dutasteride 5 mg tab , tapentadol 50 mg tab , taurine 500mg plus acetylcystine 150mg tab , telmisartan 20 mg tab , telmisartan 40 plus amlodipine 5 mg tab , telmisartan 40 mg plus chlorthalidone 12.5 mg tab , telmisartan 80 mg plus hctz 12.5 mg tab , telmisartan 80 mg tab , tab tendocare , teneligliptin 20 mg plus metformin 500 mg tab , teneligliptin 20 mg tab , tennis elbow support , tenofovir 300 plus lamivudine 300mg plus dolutegravir 50 mg tab , tenofovir 300 mg tab , tenofovir alafenamide 25 mg tab , terbinafine 250mg tab , oint terbinafine 1 percent cream tube of 10 gm , test tube 100x12mm , tetrabenzeme 25mg tab , thiocolchicoside 4 mg tab , thiocolchicoside 8 mg tab , bid details/ 2 / 123 thyroxine sodium 100 mcg tab , thyroxin 62.5 mcg tab , thyroxine 25 mcg tab , thyroxine 50 mcg tab , thyroxine 75 mcg tab , ticagrelor 60 mg tab , ticagrelor 90mg tab , timolol maleate 0.5 percent bott of 5 ml eye drop , tiotropium bromide 18 mcg dry powder rotacap bott of 30 , tiotropium bromide 9 mcg 120 metered doses oblique unit inh , tolperisone sr 150 mg tab , tolperi

CTN :41005132 Due date: 21 Jul, 202521 Jul, 2025 5.08 Lacs
Tender For conducting spark test and carrying out fiber reinforced epoxy patch work protective coating to the identified damaged portion on condenser water boxes inner surface of unit-2 during overhaul period for the year 2025-26

CTN :40464794 Due date: 16 Jul, 202516 Jul, 2025 2.20 Lacs
Tender For corrigendum : helium leak detection test for unit #5 condenser and vacuum circuit

CTN :40986313 Due date: 21 Jul, 202521 Jul, 2025 NA
Tender For outsourcing of pathology microbilogy biochemistry hemetology and nuclear test for kidney transplant unit ssb
 Loading, Please wait...

Connect us via What's Up