Web Analytics Made Easy - StatCounter

Meter Cable Tenders

Get complete information related to latest Meter Cable Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Meter Cable Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Meter Cable Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :45716660 Due date: 08 Jul, 202608 Jul, 2026 NA
Tender For providing of facility management services - lumpsum based - nagar panchayat rudayan; 3000 meter cable; consumables to be provided by buyer

Central Government/Public Sector

CTN :45730208 Due date: 08 Jul, 202608 Jul, 2026 NA
Tender For supply of flange jointing for btpn tanks to rdso drg.no.- wd-86081-s-66, item no.11, alt. no.14 or latest [ warranty period: 30 months after the date of delivery ] ]

Central Government/Public Sector

CTN :45719686 Due date: 13 Jul, 202613 Jul, 2026 44.90 Lacs
Tender For repair/ maint of lt ug cables and its connected items of masimpur mil stn incl army est at khumbigram under masimpur mil stn - e & m division items, dismantling of old unserviceable/damaged acsr or aac conductors of any size , jumper from overhead line & stacking serviceable & non serviceable material separately complete all as specified and directed., dismantling of old unserviceable/damaged stay assembly embedded in concrete including demolition of pcc and removing unserviceable meterials from site of work complete all as specified and directed., dismantling of cross-arms of ms channel or angle of any sections complete all as specified and directed., dismantling of insulators of any size/type complete all as specified and directed., dismantling earth wire or copper conductor/ cradles/stay /service feeder or distribution span complete all as specified and directed, excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable/poles and getting out in soft/loose soil complete all as specified and directed., returning, filling in trenches with soil obtained from excavation including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed., removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all all as specified and as directed., supply and laying burnt bricks of sub-class b of size 230mm x 115mm x 75mm laid in trenches for cable protection complete all as specified and as directed, supply and spread dry fine sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqd cover after punning down complete all as specified and directed. note: thickness of sand cushioning after punning down will be measured and paid separately., m&l for cutting existing road / pcc drain for taking out / laying of underground cable and including necessary earth work and making good to match with the existing surface with pcc 1:3:6 type ci using 20mm graded aggregates complete all as specified, taking down or out existing cable of sizes 10 sqmm to 70 sqmm 2/3.5/4 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, taking down or out existing cable of sizes 95 sqmm to 300 sqmm 3.5 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :-(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 10 to 70 sqmm 2/3.5/4 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc complete all as directed and specified. note :- lugs and glands will be measured and paid separately., relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 95 to 300 sqmm 3.5 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc compl

Central Government/Public Sector

CTN :45475154 Due date: 07 Jul, 202607 Jul, 2026 30.00 Lacs
Tender For corrigendum : repair / replacement and maint of lt external electric supply works and other connected items at east & west wing in tech area under ge (af) tech area gwalior - s&f in repair mccb, 4 pole, 630 amps current rating and ultimate breaking capacity ics=icu =100% 36 ka with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed., all as per item here-in-before but mccb, 4 pole, 400 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 315 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 250 amps current rating and ultimate breaking capacity 36 ka. ics = 100% of icu, all as per item here-in-before but mccb, 4 pole, 160 amps current rating and ultimate breaking capacity 36 ka . ics = 100 % of icu, all as per item hereinafter but mccb, 4 pole, 125 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 100 amps current rating and ultimate breaking capacity. 16 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 63 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, m&l for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50mtrs below ground level) connected to gi strip 25 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm gi tubing medium grade and necessary fitting for protection of gi strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, pcc chamber using pcc(1:3:6) type c-1 using 20mm graded stone aggregate, rcc cover 40mm thick (1:2:4) type b-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm c/c both ways with ms handle 8mm dia, plastering 15mm thick cm (1:6) externally up to 150mm below ground level, gi funnel with 20mm dia medium grade gi pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate no.3 of ssr part-i (2009) and connected to earth test point incl testing and marking bldg nos and writing test results (in white) on a black painted m.s. plate (size 300x300x3mm th) duly welded with angle iron of size 40x40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.note :- (i) gi strip 25 4mm and gi pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing.(ii) excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) the rates quoted by the contractor are deemed to be included for pcc chamber and pcc cover as per ssr part-1.-, m&l for preparation of old painted surfaces of lt steel tubular pole/strut, of any description and in any position 9.00/8.50 mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, gi pipe bracket of street/security light, anti climbing devices etc and providing three nos radium band strips complete all as specified and directed., supplying ,laying, jointing and testing xlpe insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes.note: the cost of taking down of lt ug cable is deemed to be included in the quoted rate, 35 sqmm 3 core, 50 sqmm 3 core, 70 sqmm 3 core, 185 sqmm 3 core, 240 sqmm 3 core, excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and get

CTN :45601130 Due date: 02 Jul, 202602 Jul, 2026 NA
Tender For bid to ras supply of door tinted glass lower , adhesive , cleaner active upper , light head lamp , throttle cable , hose bottom , ring retainer , hose top port , hose high pressure , hose sanction , hose , tooth bucket , bolt plough , nut , hose fuel , terminal , hour meter , hour meter cable , water temp gauge , lub oil temp gauge , key switch , head lamp , inertia brake , seal oil , screen , cap assy , key , bolt joint , lever fr , air breather , benjo bolt 17mm , distilled water , anabond , araldite , bty lid , copper washer 17mm , copper washer 18mm , m seal , bty lead 5mm , dc wire , joining sheet , o ring , stud , bushing , collar , ball joint

CTN :45739476 Due date: 10 Jul, 202610 Jul, 2026 NA
Tender For supply of fuel filter , engine oil filter , water separator , fuel tank cap , bottom screen filter , fuel tank strainer , head light , hrs meter , amp meter , accelerator cable , stoper cable , ignition switch , master pin , bty indicator switch , hrs meter cable , txn filter , hyd filter , radiator cap , bty lead , air cleaner filter , fuel filter cotton type , oil filter

CTN :45298008 Due date: 01 Jul, 202601 Jul, 2026 NA
Tender For bid to ras supply of xlpe cable for working voltage up to and including 1.1 kv marked to is 7098 (part 1) (q2) , miniature circuit breakers (mcb) for ac operation marked to is/iec 60898 (part 1) (q2) , supply and fixing on load change over switch ss enclosure complete with capacity 200 amp, 415 volt, 4 pole, 50 hz. , supply and fixing sheet metal enclosure spn db double door having facility to fix mcb spn as incomer and mcbs as outgoing, spn 4 ways, ip-43 , supply and fixing sheet metal enclosure tpn db double door having facility to fix mcb tpn as incommer and mcbs as outgoing tpn 4 ways, ip-43 , supply and fixing bus bar chamber 100 amp, 4 way, 415 volts enclosurre is made from crca sheet of thickness 3.15mm crca sheet cover , supply and fixing of straight through epoxy cable joint kit incl jointing materials making joints of ug electric cable 1100 v grade nominal cross sectional area not exc.50 sqmm, 3.5 by 4 core , supply and fixing straight through epoxy cable joint kit incl jointing materials making joints of ug electric cable 1100 v grade cross sectional area 240 sqmm to 300 sqmm, 3.5 core. , supply and fixing end termination epoxy cable joint kit including jointing materials for making joints of ug electric cable 1100 v grade nominal cross sectional area 240 sqmm to 300 sqmm, 3.5 core , supply and fixing of galvanised iron pipe 100 mm bore dia light grade for protection of ug cable , supply of digging nad layingg in excavation trenches not exc. 1.50 m wide and not exc. 1.50 m in depth, complete all as specified and directed. , returning, filling in including spreading, levelling, watering and well ramming in layers not exc. 250 mm in soft loose soil , supply and fixing of galvanised iron pipe 40 mm bore dia light grade for protection of ug cable , supply, installation, commissioning and testing including providing all necessary electrical connection,lt feeder panel board of size 1.0 m x 0.6 m x ) /bid number : gem/2026/b/7568567 * /dated: 22-05-2026 & & / bid document 1 / 30 & & ' ' /item category 0.5 m , supply, installation, commissioning and testing including providing all necessary electrical connections lt feeder panel board of size 0.6 m x 0.6 m x 0.5 m , supply and fixing earhing complete with gi earth plate electrode of size 600x600x6mm thick.complete all as specified and directed in boq spec file , supply and fixing earhing complete with gi earth plate electrode of size 600x600x6mm thick. complete all as specified and directed in boq spec file , supply and fixing of sub-class b brick, well burnt, laid breadth-wise along the axis of cable laid in trenches over sand cushion laid for ug cable protection, complete all as specified and directed. , supply and fixing horizontal boring under a depth of 0.65 m from the gl for passing pipe upto 40 mm bore dia , supply of digging and laying of removing excavated materials soils not exc. 50 m and depositing where directed at a level not exc.1.50 m , taking down out unserviceable or serviceable lt ug cables of nominal cross-sectional area 300 sqmm including bricks, gi pipes etc. , taking down out unserviceable or serviceable lt ug cables of nominal cross-sectional area 50 sqmm 3.5 core including bricks, gi pipes etc. , supply of digging and laying of sand cushioning dry in trenches for protection of ug cables below, above and around the ug cable laid in trenches of 230 mm spread thickness , cutting road by hard standing and making good disturbed surfaces by using pcc type-c2,1-3-6 by using 40 mm graded stone aggregate , boring of holes under road,pavement,hard standing by trenchless technology using ultra sounding technique including hdpe pipe 150 mm dia suitable for 0.4 mpa working pressure , cutting chases, chipping in making good to facings, where required and pointing in cement mortar 1- 3 to ends or edges of landings, steps, sills, sunshades, shelves, lintels etc. , submain wiring comprising single core 2 runs of 6 sqmm nominal coss sectional area frlh

CTN :45713180 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For tender for supply of speedo meter cable , blade wind shield wiper , brass nozzle 40mm with male couping , head lamp , assy tail lamp , assy turn front indicator , front direction indicator , assy rear view mirror lh rh , tail lamp bulb , horn electrical , rear view mirror

CTN :45704121 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For supply of ssl spare parts - fan belt vee ribbed , cartridge fuel filter , element lub oil filter , engine mounting pad , bushing , joint kit , hose oil brain , top tank cap , radiator top hose , radiator button hose , intake line hose long , fuel strainer , air filter clam inner , air filter outer , throttle cable , toper extension , screen , fuel filter , air cleaner filter , air cleaner outer , hours meter cable , pin master , hose 10 bsp hp 2370mm , ineritea break assy

Central Government/Public Sector

CTN :45365822 Due date: 06 Jul, 202606 Jul, 2026 39.99 Lacs
Tender For corrigendum : repair to security lights panels dg sets fire alarm ups with covered items at af stn bikaner under ge (af) nal - excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5m depth, getting out the excavated earth, forming bottom surfaces to required gradient complete all as specified and directed by engineer-in-charge., removal of excavated material soils to a distance n exc 50 m and depositing where directed at a level not exceeding 1.5m above the startly point complete all as specified and directed., returning filling in, including spreading, levelling watering and well ramming in layers n exc 25 cm as in any type of soil complete all as specified and directed., material and labour for sand cushioning using dry and clean tibba sand in two layers, first layers of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable in trenches/ducts including consolidation of each layers complete all as specified and directed. note : punned thickness shall be measured for payment., material and labour for un-reinforced pre-cast concrete cable covers, class lv type-1, flat size 250mm x 150mm x 40mm thick complete all as specified and directed., taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 2 core, 6 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 2 core, 10 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 4 core, 16 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 3.5 core, 25 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 3.5 core, 35 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 3.5 core, 50 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 2 core 6 sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by engineer-in-charge , supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 2 core 10 sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by engineer-in-charge, supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 4 core 16 sqmmlaid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by engineer-in-charge, supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 3.5 core 25 sqmm laid in trenches
 Loading, Please wait...

Connect us via What's Up