Web Analytics Made Easy - StatCounter

Meter Panel Tenders

Get complete information related to latest Meter Panel Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Meter Panel Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Meter Panel Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :45690426 Due date: 02 Jul, 202602 Jul, 2026 29.00 Lacs
Tender For corrigendum : replacement and upgradation of various blocks electrical meter panels and lt panels at ssifs campus new delhi.

CTN :45708516 Due date: 08 Jul, 202608 Jul, 2026 NA
Tender For supply of water quality testing instruments - ph meter, orp meter and ph/ec meter

CTN :45694610 Due date: 10 Jul, 202610 Jul, 2026 5.11 Lacs
Tender For supply of checking of avrs , alternator rotor , tightening of pole , protection relays , metering panel , pte pcb , over voltage , pte pcb 2019ab1 , trouble shooting , mannual avr , electrical checking , acb 4000 amp , acb 3200 amp , acb 2000 amp , acb 1600 amp , protection control card , voltage protection control , main contactor 240 volt , ct size 3000 , digital multi

Central Government/Public Sector

CTN :45304113 Due date: 25 Jun, 202625 Jun, 2026 25.00 Lacs
Tender For corrigendum : repair maint of old unsv meter panel meter box sub main wiring electric distribution board mccb mcb and other connected items under ge mis mhow

CTN :45607799 Due date: 26 Jun, 202626 Jun, 2026 9.13 Lacs
Tender For providing metering panels in place of damaged panel boards in snc shops and new panel boards in sub way shops at smc area in esd-south,tirumala

CTN :45578835 Due date: 22 Jun, 202622 Jun, 2026 26.10 Lacs
Tender For replacement of old worn out meter panel for tiv qtrs at north west moti bagh and replacement of existing silent type diesel generator set at bapudham new delhisubwork/packages:replacement of old worn out meter panel for tiv qtrs at north west moti bagh and replacement of existing silent type diesel generator set at bapudham new delhi

Central Government/Public Sector

CTN :45577056 Due date: 26 Jun, 202626 Jun, 2026 NA
Tender For supply of 50005448 cal of velocity transmitter , 50005449 cal of rh sensor , 50005460 cal of diff pres transmitter , 50005370 calibration of temp rh sensor , 50005477 cal of ph sen with meter , 50005478 cal of orp sen with meter , 50005458 cal of pressure gauge , 50005470 cal of dig water flow meter iwflmtr013 , 50005471 cal of dig water flow meter , 50005473 cal of water flow meter iwflmtr016 , 50005474 cal of anlog water flow meter iwflmtr017 , 50005475 cal of anlog water flow meter iwflmtr018 , 50005476 cal of dig water flow meter iwflmtr019 , 50006503 cal of analog water flow meter , 50006504 cal of analog water flow meter 100 to 1000l , 50006502 calibration of orp meter with sensor

Central Government/Public Sector

CTN :45582031 Due date: 07 Jul, 202607 Jul, 2026 38.00 Lacs
Tender For special repairs to indoor electric meter panel of building p-41, p-42, p-44 to p-52, p-56 and c1-p-06 to c1-p-10 at little binaga and p-29 to p-31 at kamat bay, naval base karwar and special repairs of overhead tanks and distribution line of fresh water

CTN :45581741 Due date: 01 Jul, 202601 Jul, 2026 3.63 Lacs
Tender For supply, delivery and installation of advanced testing mechanism, lab equipment for conducting daily quality of drinking water in tanuku municipality supply, delivery & installation of compact photometer pf-12plus make: mn, germany (or) any equivalent isi make model no: 919250 technical specifications: type: filter photometer with microprocessor control, self-test and auto-calibration light source: xenon lamp optical system: automatic filter wheel with 7 interference filters wave length: 345 nm / 436 nm / 470 nm / 540 nm / 585 nm / 620 nm / 690 nm plus 1 compartment for an additional filter, 860 nm led for ntu measurement wave length accuracy: ± 2 nm, bandwidth at half transmission: 10 nm?12 nm photometric range: ± 3 e photometric accuracy: ± 1 % long term stability: < 0.002 a/h measuring modes: more than 100 preprogrammed tests and special methods, absorbance, transmission, factor, standard, nephelometric turbidity measurement; 50 freely programmable methods pre programmed tests: nanocolor tube tests, visocolor eco tests and powder pillows turbidity measurement: nephelometric turbidity measurement at 860 nm (based on iso 7027), 1?1000 ntu cuvette slot: round tubes 16 mm od data memory: 1000 results, glp conform display : backlit graphic display, 128 x 64 pixel auto off: inactive or automatic shutdown after 5 min, 10 min, 15 min, 20 min, 60 min internal quality control: with nanocontrol nanocheck 2.0 operation: self-explanatory menu guidance, plastic foil keypad, test selection via parameter lists language: de / en / fr / es / it / nl / hu / pl / pt / cz / id / sl / tr / my operating range: 10?40 °c (50?104 °f), max. 80 % relative humidity (non-condensing) power supply: via usb power supply, standard or rechargeable batteries or accu-pack weight: 0.7 kg dimensions (l x w x h): 215 x 100 x 65 mm scope of delivery photometer, software dvd, manual, visocolor eco test instructions, 4 batteries, 4 empty test tubes, funnel, beaker, syringe, usb cable, calibration cuvette, cleaning cloth and certificate in rugged case hazardous material: no , supply, delivery & installation of mm42dp-ph,ec,tds portable multi-parameter water quality meter with ph, conductivity electrodes. includes: mm-42dp(main unit)+mm4-ph(1m) ph electrode+mm4-ec(1m) ec electrode make: dkk-toa corporation, japan. technical specifications : measuring method : ph : glass electrode method orp : platinum electrode method conductivity : ac bipolar method dissolved oxygen : optical type temperature : thermistor resistor display unit :custom lcd(with backlight) measurement items/ranges : ph : ph0.000 to ph14.000 mv (orp) : -2000 to 2000mv conductivity:0.1ms/m to 10s/m d0: 0.00-20.00mg/l or 0.0 to 200.0% electrical resistivity:0.1o.m to 10ko.m (converted from electric conductivity) salinity (nacl):conversion from electrical conductivity salinity (pss: practical salt):conversion from electrical conductivity total dissolved solids (tds):conversion from electrical conductivity temperature:0.0to100.0°c display range : ph : ph-2.000to ph16.000 mv (orp) : 0to99.99mg/l 0to999.9mg/l 0to9.999g/l 0to99.99g/l 0to999.9g/l (automatic/manual range switching) temperature :-5.0to110.0°c do:0.00-22.00mg/l or 0.0 to 220.0% display resolution : ph :0.01ph/0.001ph mv (orp) :1mv conductivity :0.05%fs electrical resistivity :0.05%fs, salt :0.01%(nacl)0.01psu(pss) total dissolved solids (tds) :0.01%fs temperature :0.1°c, repeatability (instrument body): ph :within ±0.006ph mv (orp) :±2mv, conductivity :±0.5%fs, do:when combined with 8mg/l ±0.1mg/l or 100%±1% electrical resistivity :±0.5%fs salt :±0.5%fs, total dissolved solids (tds) :±0.5%fs temperature :within ±0.2°c ph temperature compensation range: atc (automatic temperature compensation): 0 to 100.0? mtc (manual temperature compensation): 0 to 100.0? electrical conductivity temperature compensation range : atc (automatic temperature compensation): 0 to 100.0? mtc (manual temperature compensation): 0 to 100.0°c atc off (no temperature c

CTN :45483222 Due date: 16 Jun, 202616 Jun, 2026 6.25 Lacs
Tender For corrigendum : maintenance of sub-station equipment, feeder pillar, energy meter panel etc. at dag colony, puri during 2026-27. sh: repair of 1 no. 250 kva, 11/0.433 kv transformer at dag colony, puri.
 Loading, Please wait...

Connect us via What's Up