Get complete information related to latest Metering Unit Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Metering Unit Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Metering Unit Tenders.
Tender For corrigendum : supply of portable electromagnetic radiation tester , portable optic fiber meter with cleaver cum lan tester , handheld digital oscilloscope , digital insulation tester megger 1000v , digital multimeter , portable water depth sounder , portable anemometer , portable cordless drilling machine , fan blower , electrical tool kit box , heavy item lifter mover tool , electronic component kit , re-work station temp 100 to 450 c with air flow 100cu per min , pcb soldering magnifying glass with led lamp , storage organizer for electronic component , rechargeable emergency light , hot air gun , rechargeable torch light , bench vice with clamp
Tender For corrigendum : supply of 11kv and 33 kv outdoor oil cooled meteringunit (combined ct and pt set) under south andaman division sub-division - supply of 11kv & 33 kv outdoor oil cooled meteringunit (combined ct & pt set) under south andaman division sub-division., 11kv outdoor oil cooled ctpt combined unit 50hz three phase six bushing typewith three no. ct and one no. three phase vtwith hv neutral broughtout andearthed ilv 12/28/75 kvp ins class a, ref std refstd is16227- 1&4ct specification:ratio 80-40/5a class 0.5 burden 15va isf=7.5@ 40a stc 4ka time: 1 sec.vt specification:ratio 11kv/110v class 0.5 burden 100va voltagefactor 1.2 continuous/1.5 for 30 seconds vectorgroup/connection star/star (ynyn0). terminals: brass stud typeprimary terminals m12 in size with nut, plainwasher, spring washer & check nut. withoutterminal connector. minimum creepage distance25mm/kv.note :primary neutral to be solidly earthed.finish: tank painted colour shade 631 as peris5., 33kv outdoor oil cooled ctpt combined unit 50hz three phase six bushing type with three nosct and single nos three phase vt with hvneutral brought out and earthed ilv 36/70/170 kvpins class a ref std is16227-1&4.ct specification:ratio 25/5a class 0.5 burden 15va isf=7.5 stc4ka time :1sec.vt specification:ratio 33kv//110v class 0.5 burden 100vavoltage factor 1.2 continuous/1.5 for 30 secondsvector group/connection star/star (ynyn0).terminals:terminals: brass stud type primary terminalsm12 with nut, plain washer, spring washer &check nut. without terminal connector. minimumcreepage distance 25mm/kvnote: primary neutral to be solidly earthed.finish: tank painted colour shade 631 as peris5., 33kv outdoor oil cooled ctpt combined unit 50hz three phase three bushing three nos. ctsand one no. three phase vt with hv neutralbroughtout and earthed. ilv 36/70/170 kvp insclass a , ref std is16227-1&4.ct specification:ratio 25/5a class 0.5 burden 15va isf=7.5 stc4 ka time : 1sec.vt specification:ratio 33kv//110v class 0.5 burden 100vavoltage factor 1.2 continuous/1.5 for 30 seconds.vector group/connection star/starterminals:brass stud type primary terminals m12 with nut,plain washer, spring washer & check nut.without terminal connector.minimum creepage distance 25mm/kvnote: primary neutral to be solidly earthed.finish: tank painted colour shade 631 as peris5., 33kv outdoor oil cooled ctpt combined unit 50 hz three phase three bushing three nos. ctsand one no. three phase vt with hv neutralbroughtout and earthed. ilv 36/70/170 kvp insclass a , ref std is16227-1&4.ct specification:ratio 25/5a class 0.5 burden 15va isf=7.5 stc4 ka time : 1sec.vt specification:ratio 33kv//110v class 0.5 burden 100vavoltage factor 1.2 continuous/1.5 for 30 seconds.vector group/connection star/starterminals:brass stud type primary terminals m12 with nut,plain washer, spring washer & check nut.without terminal connector.minimum creepage distance 25mm/kvnote: primary neutral to be solidly earthed.finish: tank painted colour shade 631 as peris5., transportation, transit,insurance, packagingcharges
Tender For supply erection installation and commissioning of electromagnetic bulkflow meter at outlet integration of continuous monitoring of effluentparameters stp for local monitoring reporting supply of safety relate items forthe stpemployees masks gloves handwash aprons supply installation of luminaries safety and security of stp plant and design supply installationtesting and commissioning of64k advanced on grid solar pv systemwith micro inverter architecture and smartenergy monitoring and liasioning with electricity board at12 mld sp at nitturward
Tender For set of items - (1) supply, installation, testing and commissioning of a high- accuracy, full-bore inline electromagnetic flow meter of 40 mm size, suitable for effluent measurement in effluent treatmentplant (etp), with ip65- rated enclosure, corrosion-resistant wetted parts compatible with treated effluents, integral or remote digital display, 4-20 ma and pulse output, modbus/rs485 communication, dual power supply (220v ac, 50 hz/ optional 24 vdc), and temperature range 20 degree c to 180 degree c, includingcalibration and configuration, complete as per manufacture's specification and direction of engineer-in-charge (make: aster/upc or equivalent approved, model - mag - flow 650 or similar) - qty. - 01 no. (2) complete pvc piping system with 3-valve bypass arrangement, comprising two pvc ball valves for isolation, one pvc ball valve for bypass, and one pvc flow control valve, all connected through a high-quality pvc header of suitable diameter; including all associated fittings such as tees, crosses, elbows, reducers, sockets, plugs, unions, supports, clamps, hangers, fasteners, and anchoring accessories; with cutting, chasing, and restoration of walls/floors to original condition where necessary; scope also includes supply and installation of electrical starter (as per equipment rating), along with required control cabling, terminations, and interfacing, all executed as per ga drawing approved by rly. authority., qty. - 01 lot. detail technical specification as per annexure attached. [ warranty period: 30 months after the date of delivery ]
Tender For supply of digital water level recorder , 4 inch dwfm with telemetry meter; flw, wtr, 4in, 283cum/hr, dgtl, w/tlmtry , 6 inch dwfm with telemetry digital electromagnetic flow meter withinbuilt telemetry system