Web Analytics Made Easy - StatCounter

Methane Tenders

Get complete information related to latest Methane Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Methane Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Methane Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45726591 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at kashmir house under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, servicing of cassette type ac 3.5 to 4.0 ton capacity of any make / model with indoor and outdoor unit by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directednote: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 3.00 above but tower type ac of 2.0 to 4.0 ton capacity of any make / model any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., m&l for repair of unserviceable pcb of cassette/ tower ac of capacity 3.5 to 4.0 tr for both indoor/ outdoor units and refixing the same in respective units including opening & taking down existing unsv pcb complete all as specified and directed by engineer-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of cassette/tower ac of capacity 3.0 to 4.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by enginee

Central Government/Public Sector

CTN :45726596 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif

CTN :45739469 Due date: 21 Jul, 202621 Jul, 2026 NA
Tender For methane gas detector (fixed type lel detector) , control panel for gas and flame detectors , flame proof hooter with beacon lamp , commissioning of control panel with gas and flame detectors

CTN :45686819 Due date: 16 Jul, 202616 Jul, 2026 NA
Tender For laboratory items supply 2026 27 - department: chemistry(consumable), acetaldehyde (500 ml), acetic acid (5 lit), acetone (5 lit), zinc oxide (500 gm), kaolin (500 gm), zinc stearate (500 gm), ammonia (5.0 lit), ammonium carbonate (500 gm), ammonium ceric nitrate (100 gm), sodium lauryl sulphate, tween 80 (500 ml), ammonium nitrate (1.0 kg), gylcerol (500 gm), di butyl phthalate (500 ml), iron oxide (500 gm), benedict solution (500 ml), talcum powder (500 gm), benzoin (100 gm), carbon tetra chloride (500 ml), chromium nitrate (500 gm), copper acetate (500 gm), di chloro methane (500 ml), di ethyl ether (500 ml), di ethyl malonate (500 ml), di methyl glyoxime (100 gm), di sodium hydrogen ortho phosphate (500 gm), hydrochloric acid (5.0 lit), hydrogen peroxide (500 ml), mercuric chloride (25 gm), methanol (2.5 lit), nickel nitrate (100 gm), nitric acid (5.0 lit), petroleum ether (500 ml), phenyl hydrazine (100 gm), pottasium carbonate (500 gm), resorcinol ((100 gm)), silica gel g for tlc with binder (500 gm), sulphuric acid (5 lit), thorium nitrate (5 gm), titanium di oxide (500 gm), tungsten oxide (25 gm), yellow ammonium sulphide (20%) (500 ml), zinc nitrate (500 gm) (500 gm), zirconium chloride (25 gm), dimethyl sulfoxide emplura (500 ml), acetyl acetone (500 ml), perchloric acid (500 ml), boiling tube (10 pkt), capilliary tube (10 pkt), glass dropper, burette (pinch cock), pipette (10ml), g-3 borosil, g-4 borosil, measuring cylinders(50 ml), beaker (250 ml), china dish (80 mm), viscometer, stalagmometer, rubber tubing (for burette jets) (10 mtr.), whatman chromatography paper sheets (100), ordinary filter paper sheets (1000), whatman no.1 filter paper circles (1 pack), silica gel plate for tlc on aluminium foil, department: botany(class work material), alternaria, cercospora, mucor, volvox veg., volvox daughter colonies, volvox antheridial, volvox oogonial, volvox mixed stage, chara vegetative, chara reproductive, vaucheria veg, vaucheria sexual, vaucheria hypnospores, ectocarpus pluriclocular, ectocarpus unilocular, ectocarpus mixed stage, polysiphonia veg, polysiphonia tetrasporic, polysiphonia cystocarpic, polysiphonia antheridia, polysiphonia mixed stage, riccia veg, riccia antheridia, riccia archegonia, riccia sporophyte, riccia flutans, marchantia thallus, marchantia with gemma cup, marchantia antheridial plant, marchantia archeogonial plant, marchantia sporophyte, anthoceros veg, anthoceros sporophyte, anthoceros antheridia, anthoceros archegonia, polytrichum veg. plant, polytrichum antheridia, polytrichum archegonia, polytrichum with capsule, consumablespecimen ( museum specimen mounted in plastic jar), tobacco mosaic disease, little leaf of brinjal, citrus canker, bacterial spot disease of tomato, white rust of crucifers, green ear disease of bajra, wart disease of potato, black rust of wheat, permanent micro-prepared slides, chara reproductive, chara sexual, oedogonium vegetative, oedogonium capcells wm, oedogonium macrandrous wm, oedogonium nannandrous wm, oedogonium oogonial wm, vaucheria vegetative wm, vaucheria reproductive wm, volvox daughter colony wm, volvox oogonial colony wm, volvox antheridial colony wm, volvox zygote colony wm, mucor veg wm, mucor sporangia wm, mucor (zygote) wm, marchantia thallus ts, marchantia gemmae cup vs, marchantia gemmae wm, marchantia antheridial head vs, marchantia archegonial head vs, marchantia sporophyte vs, lycopodium stem ts, aerenchyma ts or wm, collenchyma ts or wm, sclerenchyma ts or wm, chlorenchyma, xylem elements proto and meta ts, xylem, spiral and annular vessels, xylem elements pitted vessels, xylem elements bordered vessels, phloem elements, sieve tubes, dicot and monocot stem on the same slide, dicot and monocot root on the same slide, dicot and monocot leaf on the same slide, anther wm/ts, epigynous flower ls, hypogynous flower ls, perigynous flower ls, pollen grains different types, helianthus ovary ts, basal placentation, free central placentation, superficial

CTN :45455729 Due date: 10 Jul, 202610 Jul, 2026 NA
Tender For corrigendum : supply of personal protective equipment (ppe), electrical and mechanical safety items and safety detecting devices for various power plants of assam power generation corporation limited (apgcl). - supply of safety items, safety helmet (white colour), safety helmet (grey colour), safety helmet (yellow colour), safety helmet (blue colour), safety helmet (green colour), safety helmet ( red colour), safety electrical gloves 33 kv, safety electrical gloves 430 v, natural rubber gloves (chemical resistant), rubberized cloth apron chemical (acid/alkali) resistant, disposable latex gloves (in pairs), safety ear plug, safety belts mechanical, raincoat with reflector ( high quality and full set-pant and coat type), safety face shield, welding safety gloves, mechanical hand gloves ( heat and strain resistance), safety lifebuoy ring for operation and maintenance personnel at dam, life jacket for operation and maintenance personnel at dam, frp electrical rescue rods, safety glasses/goggles, welding face shield (could be attached with any standard helmet), gum boot number 5, gum boot number 6, gum boot number 7, gum boot number 8, safety shoes (number 4 ), safety shoes (number 5), safety shoes (number 6), safety shoes (number 7), safety shoes (number 8), safety shoes (number 9), safety shoes (number 10), warning/caution tape (100 m piece each), barricading cones with reflective tape, safety net (size: 10m x 5m), raincoat with reflector, gown type, size: m, raincoat with reflector, gown type, size: l, raincoat with reflector, gown type, size: xl, raincoat with reflector, gown type, size: xxl, reflective vest green (size: xxl), reflective vest green (size: xl), reflective vest red (size: xl), reflective vest orange (size: xl), portable gas detector (hc, o2, h2s, co, lel, methane), high rising extension aluminium ladder 20 feets, high rising extension aluminium ladder 30 feets, non contact high voltage detector with insulating rod, non contact high voltage detector (wrist type), foldable stretcher, safety shower and eye wash, arc flash suit, safety belt for electrical works

CTN :45717055 Due date: 18 Jul, 202618 Jul, 2026 11.59 Lacs
Tender For supply of supply of laser methane gas detector , na , not to be bidded , dummy , sample

CTN :45291356 Due date: 01 Jul, 202601 Jul, 2026 NA
Tender For bid to ras supply of gabapentin 300mg plus methylcobalamin 1500mcg tab , gefitinib 250 mg tab , ginkgo biloba tab , gliclazide mr 30 mg tab , gliclazide 40 mg tab , gliclazide xr 60 mg plus metformin xr 500 mg tab , gliclazide 80 mg plus metformin 500 mg tab , gliclazide 80 mg tab , glimepiride 2mg plus metformin hydrochloride 500mg tab , glimepiride 2mg plus metformin hydrochloride 500mg sustained release tab , glipizide 5 mg tab , glucosamine 250 mg plus chondroitin sulphate 200 mg cap , glucosamine 500mg plus diacerein 50mg tab , glucosamine 750mg plus diacerein 50mg methyl sulfonyl methane 200mg tab , glucosamine 750mg plus diacerein 50mg tab , glucosamine sulphate 750mg plus methyl sulphonylmethaone 200mg plus oxydents and minerals tab , power dextrose monohydrate for oral use pkt of 500 gm , l glutamine powder , glutathione softgel 50mg tab , glycopyrronium inhalation solution 25 mcg 5 respules of 2 ml each , isosorbide dinitrate 20mg hydralazine 37 point 5mg tab , hydrochlorothiazide 12 point 5mg tab , hydrochlorothiazide 25 mg tab , hydroquinone 2 percent oint tube of 50gm , hydroxychloroquin 300 mg tab , hydroxyurea 500 mg cap , hydroxyzine 10mg tab , hydroxyzine 25mg tab , ibandronate 150mg tab , iguratimod 25 mg tab , imeglimin 500 mg tab , imipramine 25 mg tab , indomethacin 75mg sr tab , quadrivalent influenza vaccine split virion inactivated 0 point 5 ml dose in prefilled syringe , formoterol 6mcg plus fluticasone 250mcg inhaler 120 metered doses , formoterol 6 mcg plus tiotropium bromide 9 mcg inhaler 120 metered doses , levosalbutamol 50 mcg plus ipratropium bromide 20 mcg inhaler 200 metered doses , pheniramine maleate inj 22 point 75 mg per ml amp of 2 ml , denosumab 60 mg inj , drotaverine hcl 20mg oblic ml inj , erythropoeitin human recombinant 2000 iu , erythropoietin recombinant human 5000 iu , evolocumab 140mg inj , hepatitis b vaccine vial of 10 ml , multi vit iv 10 ml with minimum constituents having thiamine b1 30mg oblic ml pyridoxine b6 30mg oblic ml and b12 cyanocobalamin 300 mcg oblic ml inj , methylcobalamine 1500 mcg inj , methylcobalamine 500mcg inj , purified vero cell rabies vaccine , infliximab 200 iu inj , testosterone propionate 250 mg inj , triptorelin 11 oblic 25mg inj , human insulin analogue aspart premix 30 percent insulin oblic 70 percent insulin protamine aspart suspension 100 iu oblic ml monocomponent insulin,recombinant dna origin 3 ml pfs oblic pfp , insulin premixed biphasic 40 iu per ml 30 percent human neutral plus 70 percent human isophane insulin 10 ml inj , ipratropium bromide respirator soln 500mcg oblic 2ml respule , isabgol oblique isaghula husk 3 point 5 gm , isoniazid 300 mg tab , isosorbide dinitrate 10 mg tab , isotretinoin 10mg tab , itopride 150mg sr tab , itraconazole 200 mg cap , ketoconazole cream 2 percent tube of 30 gm , ketorolac 10 mg tab , l ornithine l aspartate powder sachet of 5gm , lacosamide 100 mg tab , lacosamide 200 mg tab , lacosamide 50 mg tab

State Government

CTN :45695918 Due date: 03 Jul, 202603 Jul, 2026 1.90 Lacs
Tender For enquiry for procurement and refilling of dry nitrogen gas alongwith nitrogen gas cylinder parts, testing and painting for 8.5 e-9 abl coal mills installed at unit no. 1 to 4 at sgtps, mppgcl, birsinghpur

CTN :45690132 Due date: 06 Jul, 202606 Jul, 2026 NA
Tender For supply of maintenance kit heated fid annual , maintenance kit fid i60 lcd lc , maintenance kit cold fid i60 annual , maintenance kit cold cld i60 annual , gasket set dilution filter hsu p 4000 , maintenance kit cld i60 vacuum pump , maintenance kit dilution stream annual , converter filling fid i60 methane kit , converter cld filling set low , replacement o rings ozone

CTN :45688854 Due date: 16 Jul, 202616 Jul, 2026 NA
Tender For canister zero grade nitrogen , calibration canister nh3 50 ppm , methane canister
 Loading, Please wait...

Connect us via What's Up