Web Analytics Made Easy - StatCounter

Micro Surgical Machine Tenders

Get complete information related to latest Micro Surgical Machine Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Micro Surgical Machine Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Micro Surgical Machine Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :41577585 Due date: 10 Oct, 202510 Oct, 2025 NA
Tender For corrigendum : e03-cardiology consumables ptca accessories/drugs - ptca wire torquers, guide wire torquer, ptca introducer needle (y connector compatible), push only - torque minimal catheters, push only - torque minimal catheters, push only - torque minimal catheters, push only - torque minimal catheters, torqueable braided microcatheters, torqueable braided microcatheters, torqueable braided microcatheters, dual lumen and side branch acccess microcatheters, dual lumen and side branch acccess microcatheters, guide extension catheters, guide extension catheters, guide extension catheters, thrombus aspiration catheter, thrombus aspiration catheter, thrombus aspiration catheter, low tip load cto wires ( 1.0 gf), low tip load cto wires ( 1.0 gf), low tip load cto wires ( 1.0 gf), medium tip load wires (1.0 3.0 gf), medium tip load wires (1.0 3.0 gf), medium tip load wires (1.0 3.0 gf), medium tip load wires (1.0 3.0 gf), high tip load wire ( 4.0 gf), high tip load wire ( 4.0 gf), high tip load wire ( 4.0 gf), cto support wire, re entry / support / externilisation wires, re entry / support / externilisation wires, re entry / support / externilisation wires, re entry / support / externilisation wires, re entry / support / externilisation wires, cto speciality balloon, cto speciality balloon, cto speciality balloon, workhorse coronary guidewires, workhorse coronary guidewires, workhorse coronary guidewires, workhorse coronary guidewires, workhorse coronary guidewires, workhorse coronary guidewires, workhorse coronary guidewires, ffr guide wires, ffr guide wires, ffr guide wires, ivus / hd ivus catheter, ivus / hd ivus catheter, coronary oct (optical cohorence tomography) catheter, rotational atherectomy(complete set), orbital atherectomy device (complete set), ivl balloon (set), ecg electrodes, ecg electrodes, ecg electrodes - pediatric, j-tip teflon coated wire (0.035), straight tip teflon wire (0.035), straight tip teflon wire (0.032), exchange-length ptfe wire, superstiff / extrastiff wire, hydrophilic wire, support wire

CTN :41577586 Due date: 10 Oct, 202510 Oct, 2025 NA
Tender For corrigendum : e-06 cardiology consumables eps /pace maker device /rdn - quadripolar catheters, quadripolar catheter connectors, quadripolar catheters, quadripolar catheter connectors, decapolar catheters- deflectable, decapolar catheter connectors, halo catheters and connectors, ablation cateter- non irrigated, ablation catheters- irrigated tip, ablation catheter- bidirectional, ablation connectors, impedance based 3 d mapping patch (navx), bidirectional irrigated ablation catheter for 3 d, bidirectional high density grid mapping catheter size, bidirectional contact force mapping ablation catheter, high density mapping catheter, reference patch for carto, 3 d unidirectional irrigated mapping ablation catheter, 3 d bidirectional irrigated mapping ablation catheter, contact force sensing catheter compatible with carto 3 mapping and rf ablation, vhpsd based ablation catheter for af, ablation connector, bidirectional steerable sheath, transseptal sheaths, brk needle for trans septal puncture, intracardiac echocardiography (ice), irrigation tubing set, valley lab patches, permanent pace maker (ppi) single chamber, permanent pace maker (ppi) dual chamber, permanent pace maker (ppi) dual chamber physiological pacing - septal, leadless pacemaker, implantable cardioverter defibrillators (icd) aicd single chamber, implantable cardioverter defibrillators (icd) aicd dual chamber, crt d cardiac resynchronization therapy, crt p cardiac resynchronization therapy, temporaray pacemaker lead - standard tpi lead, balloon tip tpi lead, temporary pacemaker box - pulse generator, renal denervation system

CTN :41577587 Due date: 10 Oct, 202510 Oct, 2025 NA
Tender For corrigendum : e-08cardiology consumables dignostic and guding cathetrs/doc extention wire/iabp/coronery penumbra - diagnostic cathetrs judkins, diagnostic cathetrs judkins, diagnostic cathetrs judkins, diagnostic cathetrs pigtail, diagnostic cathetrs pigtail, diagnostic cathetrs pigtail, diagnostic cathetrs amplatz, diagnostic cathetrs amplatz, diagnostic cathetrs amplatz, diagnostic cathetrs multipurpose, diagnostic cathetrs multipurpose, diagnostic cathetrs multipurpose, diagnostic cathetrs ima, diagnostic cathetrs ima, diagnostic cathetrs ima, diagnostic cathetrs tiger / jacky, diagnostic cathetrs tiger / jacky, diagnostic cathetrs tiger / jacky, diagnostic cathetrs marker pigtail, diagnostic cathetrs rare, guiding catheter extra back up, guiding catheter extra back up, guiding catheter judkins, guiding catheter judkins, guiding catheter judkins (side hole), guiding catheter judkins (side hole), guiding cathetrs amplatz, guiding cathetrs amplatz, guiding catheter multipurpose, guiding catheter multipurpose, guiding catheter ima, renal guiding catheters, guiding catheter tiger / ikari, guiding catheter rare, doc extension wire, doc extension wire, doc extension wire, iabp balloon, iabp balloon, penumbra aspiration catheter - coronary

corporations/Associations/Others

CTN :41991909 Due date: 13 Oct, 202513 Oct, 2025 90.99 Lacs
Tender For tender for procurement ofanaesthetics items (second attempt) - 1, 30, m1, blue radio opaque line, low pressure high volume cuff, clear tubing, painted pilot balloon, smooth murphy eye thermostatic, minimizes risk of trauma, one way valve for efficient and easy inflation and deflation of cuff, 100.00, thermosensitive pvc cuffed et tube no. 3.5, number, 33/009/0334/00/0/0/0, 50.00, 5, 30, m1, blue radio opaque line, low pressure high volume cuff, clear tubing, painted pilot balloon, smooth murphy eye thermostatic, minimizes risk of trauma, one way valve for efficient and easy inflation and deflation of cuff, 100.00, thermosensitive pvc cuffed et tube no. 5.5, number, 33/009/0339/00/0/0/0, 50.00, 9, 30, m1, blue radio opaque line, painted pilot balloon, smooth murphy eye thermostatic, minimizes risk of trauma, portex material, 100.00, thermosensitive pvc uncuffed et tube no.3, number, 33/009/0343/00/0/0/0, 5.00, 13, 30, m1, blue radio opaque line, painted pilot balloon, smooth murphy eye thermostatic, minimizes risk of trauma, portex material, 100.00, thermosensitive pvc uncuffed et tube no.5, number, 33/009/0348/00/0/0/0, 5.00, 17, 30, m1, blue radio opaque line, painted pilot balloon, smooth murphy eye thermostatic, minimizes risk of trauma, portex material, 100.00, flexomettalic endotracheal tube no 5/5.5/6/6.5/7/7.5/8/8.5/9/9.5/10, number, 33/009/0353/00/0/0/0, 10.00, 21, 30, m1, thermo sensitive clear pvc tube, set including stylet, connectors & suction catheters with radio opaque line. should have y adaptor to allow selective lung ventilation, differential lung ventilation and cpap. colour coded,lablled extension tube and pilot balloons differentiate bronchial and tracheal airways.size : 26f ,28f ,32f, 35 f, 37 f, 39 f,41 f, 17100.00, laryngeal mask airway no 1/1.5/2/2.5/3/4/5, number, 33/009/0357/00/0/0/0, 17.00, 25, 30, m1, epidural touhy needle 18gx 3.5 in. pencil spinal needle 27gx 5.5 in. epidural catheter 20g.closed tip. 10ml glass luer lock lor tray (kit). filter 0.22 micron., 2300.00, epidural set with epidural needle, number, 33/009/0361/00/0/0/0, 10.00, 29, 30, m1, needle shpuld be have echogenicity to visualise needle shaft and needletip in sonography. excellent puncture and gliding properties through smooth surface precise stimulation through the non-insulated needle tip. short bevel (30?), disposable, needle of different length, fully insulated from shaft to tip to precisely locate the nerve with low current. comfortable needle hub & adequate length of electric cable with 2mm pin & injection tube with l.l. connector., 5800.00, rae tube with cuff (south pole) no 4.5/5/5.5/6/6.5/7/7.5/8/8.5/9, number, 33/009/0365/00/0/0/0, 60.00, 33, 30, m1, an innovative and unique bifucated bronchus blocker with y shaped distal end that mirrors the bifurcation of trachea allowing intuitive placement of the cuffs in the right or left bronchus without the need for navigation. the 75cm long & 7fr sized central lumen of ez blocker tm allows oxygen administration (cpap) with the help of an oxygen adaptor by attaching it to one of the 2 proximal ends to the isolated lung during procedure and the other not in use should be closed using one of the 2 blue dust caps. it also allows co2 flow check to ensure cuff is providing a full seal. low volume cuffs made of polyurethane, providing optimal seal. a multiport adaptor (4 port) with scope lid allow introduction of fibre optic or video bronchoscopes and suction catheters. the securement cap connecting the multiport adaptor allows the catheter to be tightenes once properly positioned, which minimizes the need to manipulate by securing placement and reduces the potential for the cuffs to become dislodged. radiopaque shaft provides visibility under x - ray and depth markers indicating the depth of insertion., 1500.00, laryngeal mask airway fastrach no 3/4/5, number, 33/009/0369/00/0/0/0, 10.00, 37, 30, m1, the aintree intubation catheter is a blunt - tipped, 19 fr radio - opaq
 Loading, Please wait...

Connect us via What's Up