Tender For repair maintenance of various types of summer appliances and other connected items at af station jammu and kaluchak under ge (af) jammu - repair to split ac and window ac, supply of labour only for attending and rectification of daily complaints for day to day maintenance and servicing for split ac/window ac /hot & cold air conditioner/dual inverter air conditioners/flame proof ac of any capacity and make installed in various locations of 23 wing af jammu and 256 su kaluchak (excluding sundays and holidays) with high skilled refrigerator mechanic and helper including detecting fault of split/window air conditioner complain and servicing all unserviceable parts for split/window ac and replacement of u/s parts & repair of all necessary items and handed over to user for serviceable condition within 24 hours for minor faults and within 48 hours for major faults all as specified and direted by engineer in charge.note: (a) contractor has to employ highly skilld refrigerator mechanic with helper and necessary t&p for attending day to day complaints of ref and ac failing which recovery shall be made at two times of quoted rate. (b) rate quoted shall be inclusive of transport from af station to work shop & back shifting within permises.( c) any parts shall be replaced and paid separately as "supply only " against relevant item (s) of this schedule. , m&l for shifting of split type ac/ window type ac capacity upto 2 ton , including submain/point wiring all electrical items and drilling, making good on surface of pcc concreting, white cement plastering and all necessary items and transporting complete one location to other location in 23 wing area and 256 su kaluchak area replacing unserviceable parts and handing over the machine/ equipment in serviceable condition to the user including fixing to new location all as specified and directed by engineer-in-charge., supply only the following items to incorporate against repairable summer appliances window / split type acs against relevant items no 2.00 and 3.00 here-in- before: -, blower motor complete suitable for window type ac upto 2.0 ton all as specified and directed by engr-in-charge., indicator suitable for window type ac up to 2 tonall as specified and direted by engineer in charge., thermostat switch suitable for window type ac up to 2 tonall as specified and direted by engineer in charge., control knob suitable for thermostat switch and selector switch of window type ac up to 2 tonall as specified and direted by engineer in charge., selector switch suitable for window type ac up to 2 ton all as specified and direted by engineer in charge., relay along with box suitable for window type ac upto 2 ton all as specified and direted by engineer in charge., plastic air filter suitable for window ac upto 2 tr. make- voltas/ bluestar/ lg/ samsung/ as on site., outer unit condenser fan motor suitable for window type ac up to 2 ton. make- voltas/ bluestar/ lg/ samsung/ as on site., fan for outer unit condenser motor suitable for window type ac up to 2 ton. make- voltas/ bluestar/ lg/ samsung/ as on site., front grill as per existing suitable for window type ac upto 2 ton.make- voltas/ bluestar/ lg/ samsung/ as on site., plastic air filter suitable for split ac indoor unit ac upto 2 tr. make- voltas/ bluestar/ lg/ samsung/ as on site., s&f power control board ( pcb ) for window type /split ac up to 2 ton . make- voltas/ bluestar/ lg/ samsung/ as on site., s&f power control board ( pcb ) for split ac indoor unit dual inverter/hot and cold ac up to 2 ton . make- voltas/ bluestar/ lg/ samsung/ as on site., s&f power control board ( pcb ) for split ac out door unit dual inverter/hot and cold ac up to 2 ton . make- voltas/ bluestar/ lg/ samsung/ as on site., wiring kit suitable for split ac and window type ac upto 2 ton., condenser fan motor complete with fan suitable for out door unit of split type air conditioner upto 2 ton. make- voltas/ bluestar/ lg/ samsung/ as
Tender For special repairs to lt panels and connected items at pyro, pinaka, nag mixture building, magazine area and ap building in hemrl, pune - taking out old serviceable/unserviceable lt panel/capacitor panel of any description or capacity keeping aside in safe custody for schedule of credit complete all as specified and directed, supply, fixing and commissioning of cpri approved factory made lt cubicle panel board outdoor type conforming to is/iec-61439-1&2 : 2011 with canopy, louvers & shutters made out of 3.15 mm thick crca sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front and rear opeing and lcoking arrangement, degree of protection ip 56, 415 volts, 3 phase, 4 wire, 50 hz having aluminium bus bar of capacity 1200 amps tpn duly colour coded and for neutral supported with dmc/smc insulator colour coded with heat shrinkable sleeve having short circuit current with minimum 65 ka for one second and suitable for internal connection including instantaneous over load and earth fault relays complete with digial type voltmeter and ammeter inclduing suitable range of cts of metering, selector switches for voltmeter and ammeter, set of three led type indicating lamps duly wired with suitable size of copper cables and panel board shall be grouted in the ground with suitable size of foundation in pcc 1:2:4 type b1, ms channels 50 x50 x 6mm with nut bolts, wahsers, etc. suitable for fixing with bus duct including comprising of the following:-incoming: (a) acb adjustable type with thermal magnetic release 4 pole, 800a, 415v, 50 ka, 50 hz - 01 no. outgoing: (b) mccb 4p, 400 amps, 36 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 03 nos, (c) mccb 4p, 125 amps, 25 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 nos, (d) panel mounted type digital multifunctional energy meter a, v,z, kw, pf t operated, lt 3 phase, 4 wire inclding ct ratio 200/5 - 04 nos, (e) control mcb c curve, sp, 6 to 32a, 10ka, c curve - 02 nos, (f) led phase indicator (r,y & b) - 01 set. (pyro sub stn), supply, fixing and commissioning of cpri approved factory made lt cubicle panel board outdoor type conforming to is/iec-61439-1&2 : 2011 with canopy, louvers & shutters made out of 3.15 mm thick crca sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front and rear opeing and lcoking arrangement, degree of protection ip 56, 415 volts, 3 phase, 4 wire, 50 hz having aluminium bus bar of capacity 1200 amps tpn duly colour coded and for neutral supported with dmc/smc insulator colour coded with heat shrinkable sleeve having short circuit current with minimum 65 ka for one second and suitable for internal connection including instantaneous over load and earth fault relays complete with digial type voltmeter and ammeter inclduing suitable range of cts of metering, selector switches for voltmeter and ammeter, set of three led type indicating lamps duly wired with suitable size of copper cables and panel board shall be grouted in the ground with suitable size of foundation in pcc 1:2:4 type b1, ms channels 50 x50 x 6mm with nut bolts, wahsers, etc. suitable for fixing with bus duct including comprising of the following:-incoming: (a) acb adjustable type with thermal magnetic release 4 pole, 800a, 415v, 50 ka, 50 hz - 01 no. outgoing: (b) mccb 4p, 400 amps, 36 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 nos, (c) mccb 4p, 315 amps, 25 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 nos, (d) mccb 4p, 250 amps, 25 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 02 nos (e) panel mounted type digital multifunctional energy meter a, v,z, kw, pf t operated, lt 3 phase, 4 wire inclding ct ratio 800/5 - 04 nos, (e) con
Tender For supply erection and commissioning of 2500 no communicable compact fault passage indicator sets fpi on 33kv and 11kv feeders in tgnpdcl warangal..
Tender For for electrical and communication engineering department lab equipments are required as per new syllabus - upgradation of labarotariesece department, 8051 micro controller kit operating voltage: +5 v dc. flash memory: 4 kb (at89c51) / 8 kb (at89s52). ram: 128 bytes internal ram. 16 2 alphanumeric lcd display. push buttons / tactile switches. dip switches for digital input. inbuilt adc interface: ldr, potentiometer. inbuilt dac interface. inbuilt stepper motor driver with stepper motor. inbuilt dc motor driver with dc motor. 1 4 led array, 1 4 keypad, 1 relay. 1 buzzer, 16 2 lcd display, 1 pwm driver. 1 hardware interrupt key, inbuilt rtc. inbuilt eeprom and uart module. 4 7-segment display. supports both assembly and c language programming. pc interfaceable., single phase induction motor1 hp, 230 v ac, 1500 rpm with loading arrangement 1 no.voltmeter: (0 300) v ac, 96 96 mm with input terminals 1 no.ammeter: (0 10) a ac, 96 96 mm with input terminals 1 no.wattmeter: 2 kw, 96 96 mm with input terminals 1 no.power factor meter: 96 96 mm with input terminals 1 no.auto transformer: 0 300 v, 1 variac 1 no.mcb: 2-pole, 40 a / 230 v ac 1 no.digital rpm indicator with proximity sensor 1 no.aluminium brake drum: 230 mm diameter 1 no.spring balance: (0 25) kg 02 nos.circuit diagram printed on front panel with instruments and connecting terminals.motor and loading arrangement mounted on rigidchannel frame with anti-vibration mounting pads, m12 1.5 bolt & nut, 85 mm dia 4 nos.mild steel powder-coated electrical panel tablesetup., auto transformerinput: 230 240 v ac, 50 hz.output: variable (0 270) v ac.rating: 1 kva.insulation class: class f / class h.construction: copper winding with carbon brush arrangement.mounting: bench-top / panel type.protection: suitable fuse / overload protection., dth trainerkitpower supply: 200 v to 240 v ac, 50 hz. dish antenna: 1.5 ft aluminium steerable dish antenna.lnb (low noise block down converter): input frequency: ku-band. output frequency: 950 mhz to 1450 mhz. conversion gain: 65 db. noise temperature: 35 k (max).set-top box receiver in trainer form: if frequency: 70 mhz. video bandwidth: 50 hz to 5 mhz. video output level: 1 vpp at 75 load. video polarity: normal/inverted, switch selectable. audio subcarrier frequency:tunable from 5.0 mhz to 8.0 mhz. remote control provided. hdmi cable: 10 m. controls: channel selection. volume control. fault simulation: five built-in simulated faults for troubleshooting experiments. if signal disconnected. video output fault. audio mute fault. tuner misalignment. rf output interruption. pcb size: 15" 12" with multicolour section-wise block diagram.standard accessories: 1.5 ft dish antenna. lnb. trainer pcb. dish connecting wire. audio-video cable. user manual. acrylic cover. hardware materials for assembly of dish antenna. additional features: dth subscription connection with doordarshanfree channels., sim reader trainerkitpower supply: operates on 230 v ac 10%, 50 hz mains supply. built-in regulated smps power supply. operating dc supply: 5 v / 12 v with overload and short-circuit protection.sim card interface: supports gsm sim cards compatible with 2g / 3g / 4g / 5g networks. sim card read/write interface. supports sim card initialization, authentication, and communication functions. compatible with standard 6-pin / 8-pin sim card sockets.communication interface: usb 2.0 interface for pc communication. rs-232 serial communication interface. uart communication facility for embedded system interfacing.sim operating parameters: selectable sim clock frequencies: 3.579 mhz 7.159 mhz 14.318 mhz sim supply voltage selection facility. sim reset and activation control. supported protocols and standards: gsm etsi 07.07 and etsi 07.05 at command support. iso/iec 7816 smart card communication support. sim communication command monitoring facility. hardware features: on-board sim card socket. led indication for: power status sim detection reset activity data transmission/r
Tender For street light accessories and phase wire work in losal area - work, supplying and drawing of xlpe insulated lt aerial bunched aluminium conductor cable confirming to is 14255/1995 and is 398 (pt-4)/ 1994 and as per discom specs. on existing cross arms through i hook with all necessary t&p required including binding and twisting etc. complete in all respect as required. all as per pre approved by engineer in-charge. for additional technical parameters of products/ work , refer annexure "a"attached with this bsr ., 1 x 25 sq. mm. + 1x25 sq. mm. (insulated), supply and fixing of following lt supporting accessories with nut bolt & clamps made out as per standard discoms specifications with two coats of red oxide and two coats of aluminium paint etc. as required. all as per pre approved by engineer in-charge.for additional technical parameters of product / work refer annexure a attached with this bsr, suspension clamp with eye hook & pole clamp, dead end clamp with eye hook & pole clamp, p & fixing powder coated crca sheet enclosures on existing angle iron frame by means of nuts and bolts and making holes , din rail etc. as required.for additional technical parameters of product / work refer annexure a attached with this bsr, 2.0 mm thick, providing & fixing of ac operated heavy duty 230 /440 volt power contactor as per pwd specification for electrical works, isi marked is/iec 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, din rail mounting type including making connections, testing etc. as required. all as per pre approved by engineer in-charge. for additional technical parameters of products/ work , refer annexure "a" attached with this bsr ., 4 pole power contactors with following ac 1 rating 63 amp, providing & fixing of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and ac1 rating of 16-20 amperes including making connection, programming conforming to iec 60730-1 and 60730-2-7 etc. as required. all as per pre approved by engineer in-charge. for additional technical parameters of products/ work , refer annexure "a" attached with this bsr ., one day & week reserve (analog type ), sitc of 3 /4 pole current limiting moulded case circuit breaker (mccb) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 v, 50 hz; o/l & s/c settings , conforming to is/iec 60947 p -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, breaking capacity ics = 100% icu. u imp =8 kv, rated insulation voltage 690 v. provision for uvr , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections etc. as required.oem shall have submit nabl / cpri / erda accrediated lab type test certificate before execution all as per pre approved by engineer in-charge. for additional technical parameters of product/ work refer annexure a attached with this bsr, 4 pole mccb with thermal magnetic release up to 100 amp , 10 ka, fixed o/l & fixed s/c setting, pipe earthing as per is:3043- 1987 with 3.0 mtr. long, 40 mm dia. b class g.i. pipe is: 1239 (part-1) 2004, equivalent to bs : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and heavy duty weather proof poly-propylene earth pit chamber with lockable jam free lid suitable for safe working load 5000 kg or more of size top dia. 225 to 260 mm, bottom dia 300 to 350mm. and height 250 to 300 mm. and embodying the pipe compl
Tender For supply of eee lab equipments - digital ic trainerkit, 8085 microprocessor trainer with power supply, 8051 microcontrollertrainerkit with power supply, 8279 keyboard / display interface board, device characteristics (for scr, mosfet, triac and igbt kit with built-in / discrete power supply and meters), single phase scr based half controlled converter and fully controlled converter along with built-in / separate / firing circuit / module and meter, mosfet based step up and step down choppers (built-in / discrete), igbt based single phase pwm inverter module / discrete component, igbt based three phase pwm inverter module / discrete component, scr & triac based 1 phase ac controller along with lamp or rheostat load