Tender For : roof mounted ac package unit (rmpu) for lhb eog ac coaches in coach sets consisting of rmpu(with r-407c refrigerant)-02 nos. and microprocessorcontroller unit -1 no., with supply of bellows set consisting of01 no. supply air bellow, 02 nos fresh air bellows & 02 nos. return air bellows ducts made of meta aramid/ paraaramid fabric with silicon rubber coating on both sides to spec. no. rdso/pe/spec/ac/0197-2020 (rev-0), rmpuas per specification no rdso/pe/spec/ac/0061-2005, rev-1, type-i & microprocessorcontroller unit tordso/pe/spec/ac/0139-2009, rev-1, complete with accessories, as per scope of supply as in the rdsospecification.rdso item id: 3100018
Tender For roof mounted ac package unit rmpu type-i for lhb eog coaches in coach set,consisting of rmpu with r407-c refrigerant -02 nos. to the rdso specification no. rdso /pe/spec/ac/0061-2005 rev-1 or latest and microprocessorcontroller unit- 01 no. as per to the rdsospecification no. rdso/pe/ spec/ac/0139-2009 rev.1 or latest type - i complete with accessories asper scope of supply as envisaged in the rdso specifications. 1.rdso approved sources only beconsidered.2.earthing lug arrangement on rmpu shall be as per drg.no.icf/sk3-7-6-035.3.packing instruction as follows:roof mounted ac package unit packed with corrugated paper with waterproof jute fabric and supplied and stacked in pallets at icf.the pallets should be painted and have firms logo for identification.the firm will collect empty pallets only after ac package unit is loaded in the coach [ warranty period: 30 months after the date of delivery ]
Tender For supply of roof mounted ac package unit rmpu type-i for lhb eog ac coaches in coach set, consisting of rmpu with r407-c refrigerant -02 nos. to the rdso specification no. rdso/pe/spec/ac/0061-2005 rev-1 and microprocessorcontroller unit- 01 no. as per the rdso specification no. rdso/pe/spec/ac/0139-2009 rev.1, type # i complete with accessories as per scope of supply as envisaged in the rdso specifications and without air bellows (supply air, fresh air and return air). note: 1. rdso drawing no rdso/pe/sk/ac/0069-2004, rev-3 or latest shall be followed. 2. standardisation of location of ntc, ohp & esti sensors shall be as per rdso modification sheet no rdso/pe/ms/ac/0087 (rev-0)-2022. 3. mounting details for rmpu switch panel shall be provided as per drawing no.icf/sk3-7-2-062 alt- a. 4. differential pressure switch (dps) based heater protection system for rmpu shall be provided as per rdsomodification sheet no. rdso/pe/ms/ac/0089 (rev-0)-2022. 5. packing instruction as per pi-026 ver.1.0 [ warranty period: 30 months after the date of delivery ]