Tender For 22/2025-26 purchase of laqshya instruments - purchase of instruments ( laqshay), radiant warmer- technical specification of radiant warmer with baby bassinet a radiant warmer is used to keep the patient s core temperature stable at 37 o c. it should be microprocessor controlled radiant warmer with manual and servo options. it should have facility to display both skin and air (ambient) temperature separately.. it should have audiovisual alarm facility for overheating beyond set temperature range. it should have alarm facility for patient temperature less than or greater than the required temperature i.e. above or below the set range. it should rotate and swivel in different direction, so as to allow taking x-ray. the light should be dazzle free. it should have alarm for power failure. it should have alarm for heater failure and auto cut off for high temp. it should have alarm for probe failure. it should have time out alarm in manual mode. it should have facility to auto reset the system in case of hang up caused by power fluctuation. it should have manual setting for high and low alarm setting. in servo mode, the heater output should be controlled to maintain the baby at the required set temperature. in manual mode, the heater output should be directly controlled by a setting on the front panel should have a facility to lock the keyboard to avoid unwanted user. the desired temperature range from 25 to 40 degree c. the resolution should be 0.1 degree c halogen based observation light should be provided for observing the baby. it should be mounted on a pole with sturdy base with lockable castors power supply: power input to be 220-240 vac, 50hz fitted with indian plug. certificate of calibration and inspection from the factory. warranty: comprehensive warranty for 5 years after warranty documentation: user, technical, maintenance manuals to be supplied ce, iso certified , fetal doppler - technical specification of fetal doppler should be compact, table type and light weight. large lcd display for display of fetal heart rate. back light for better visibility display signal quality, low battery, etc., high sensitivity doppler probe of frequency 2.0 mhz ultra sound intensity 10mw/cm2. built-in speaker with output not less than 1.0w should work on rechargeable batteries with minimum battery time of 300minutes. battery charger and spare set of batteries aa type to be supplied. volume control facility and audio output for ear phone should be available. heart rate range should be from 50 to 240 b pm with accuracy of + /-2% should be water proof body. should have facility for fhr data transfer to pc. doppler probe should be light weight with holder facility when not in use. should be supplied with carrying case. machine should be iso mark, baby digital thermometer - technical specification of baby digital thermometer range 0.1 to 1000 degree centigrade measurement mode- min, max, average, differential, dual temperaturereading measurement unit- degree centigrade, degree fahrenheit,kelvin temperature probe with connecting cable relative humidity10 to 90% rh non-condensing ip rating- ip 40 g) probe response time 2-3 seconds it should be who & unicef standards, delivery trolley/patient stretcher trolley- technical specification of patient stretcher trolley overall size: 1905mm l x 710mm w x 660mm to 910 mm h. stretcher dimension 1830 mm l x 555 mm w. two section top. height adjusted by foot operated maintenance free hydraulic pump. height adjustment shall be obtained by hydraulically operated mono block type linear actuator pump foot operated actuation having stroke of 140 +/- 5 mm, push force 10 kn at 270 bars, number of complete pump stroke 22 to 24 for full stroke length x-ray permeable removable stretcher, backrest raised on ratchet. quick trendelenburg as well as reverse trendelenburg positions shall be provided with easily accessible operating handle provided with two gas springs for easy action. s.s. saline rod with 12 mm dia s.s
Tender For 22/2025-26 purchase of laqshya instruments - purchase of instruments ( laqshay), radiant warmer- technical specification of radiant warmer with baby bassinet a radiant warmer is used to keep the patient s core temperature stable at 37 o c. it should be microprocessor controlled radiant warmer with manual and servo options. it should have facility to display both skin and air (ambient) temperature separately.. it should have audiovisual alarm facility for overheating beyond set temperature range. it should have alarm facility for patient temperature less than or greater than the required temperature i.e. above or below the set range. it should rotate and swivel in different direction, so as to allow taking x-ray. the light should be dazzle free. it should have alarm for power failure. it should have alarm for heater failure and auto cut off for high temp. it should have alarm for probe failure. it should have time out alarm in manual mode. it should have facility to auto reset the system in case of hang up caused by power fluctuation. it should have manual setting for high and low alarm setting. in servo mode, the heater output should be controlled to maintain the baby at the required set temperature. in manual mode, the heater output should be directly controlled by a setting on the front panel should have a facility to lock the keyboard to avoid unwanted user. the desired temperature range from 25 to 40 degree c. the resolution should be 0.1 degree c halogen based observation light should be provided for observing the baby. it should be mounted on a pole with sturdy base with lockable castors power supply: power input to be 220-240 vac, 50hz fitted with indian plug. certificate of calibration and inspection from the factory. warranty: comprehensive warranty for 5 years after warranty documentation: user, technical, maintenance manuals to be supplied ce, iso certified , fetal doppler - technical specification of fetal doppler should be compact, table type and light weight. large lcd display for display of fetal heart rate. back light for better visibility display signal quality, low battery, etc., high sensitivity doppler probe of frequency 2.0 mhz ultra sound intensity 10mw/cm2. built-in speaker with output not less than 1.0w should work on rechargeable batteries with minimum battery time of 300minutes. battery charger and spare set of batteries aa type to be supplied. volume control facility and audio output for ear phone should be available. heart rate range should be from 50 to 240 b pm with accuracy of + /-2% should be water proof body. should have facility for fhr data transfer to pc. doppler probe should be light weight with holder facility when not in use. should be supplied with carrying case. machine should be iso mark, baby digital thermometer - technical specification of baby digital thermometer range 0.1 to 1000 degree centigrade measurement mode- min, max, average, differential, dual temperaturereading measurement unit- degree centigrade, degree fahrenheit,kelvin temperature probe with connecting cable relative humidity10 to 90% rh non-condensing ip rating- ip 40 g) probe response time 2-3 seconds it should be who & unicef standards, delivery trolley/patient stretcher trolley- technical specification of patient stretcher trolley overall size: 1905mm l x 710mm w x 660mm to 910 mm h. stretcher dimension 1830 mm l x 555 mm w. two section top. height adjusted by foot operated maintenance free hydraulic pump. height adjustment shall be obtained by hydraulically operated mono block type linear actuator pump foot operated actuation having stroke of 140 +/- 5 mm, push force 10 kn at 270 bars, number of complete pump stroke 22 to 24 for full stroke length x-ray permeable removable stretcher, backrest raised on ratchet. quick trendelenburg as well as reverse trendelenburg positions shall be provided with easily accessible operating handle provided with two gas springs for easy action. s.s. saline rod with 12 mm dia s.s
Tender For request proposal for supplying various equipment, chemicals, standard reference microbial cultures, glasswares/ plasticwares and general items in 13 numbers of district level water testing laboratories of jharkhand a-ranchi zone - refrigerator- ( 265 litre approx., double door ),make & model: branded ( is standard), analytical balance-( 4digit), weighing capacity of 220g, externally calibrated by nabl accredited lab/agency with calibration certificate, make & model: branded) ( is standard), ph meter-(measuring range ph0.0-14.0), make & model: branded ( is standard), hot plate with magnetic stirrer-(power: 2000 watt approx., operating volts: 230 15 volts a/c), stirring capacity : 50-1500 rpm, plate size : 1 ft *1.5ft (approx), make & model: branded ( is standard), bacteriological incubator-digital construction -double walled construction outer body made of mild steel powder coated & inner body made of stainless steel, insulation : glass woll insulation between two walls. inner size : 18" x 18" x 24", rating watts 750, no. of shelves 3, capacity 120 ltrs, temp range- 5 c - 60 c accuracy +/- 0.5 c, temp controlled by : controlled by pid micro process controller with dual display. selves : with g.i. wire mesh selves, door : 2 door inner acrylic door to view sample & outer metal door with air circulation motor with blower for uniform temperature throughout chamber. heater : special nichrome heater designed for long life & saving of power consuption. thermometer type : electronic with digital display. make & model : branded ( is standard), laminar air flow chamber(biosafety cabinet)-external dimensions (lxwxh) in inches and mm:40 x34.25 x56.7, (1020 x870x 1440) work area dimensions: 34.45 x24 x22.52 (857x610x572) material of construction: galvanised iron sheet with epoxy polyester thermosetting powder coating of 80 microns, 1.5mm thickness/stainless steel grade 304,1.2mm for ss modelsbody finish: glossy off white colour for gi powder coated table top: 1.2mm ss 304 sheet of matt finish pressed on 25mm solid nuwud board side glass: 6mm float glass encased in stainless steel channels front door: frameless gas spring loaded swinging type polycarbonate 6mm thickness wheels and levelling lugs: pu solid wheels with plated brackets and metallic powder coated design: front bottom loading pre-filters or completer work area with stainless steel including hepa grill cleanliness class: iso standard 14644-1- class 5 stages of filtration: a.pre-filters= 10 with an efficiency of 90 % washable hdpe media in frp pu coated frame b.mini pleat hepa filter encased aluminium frame with an efficiency of 99.995% motor blower assembly: variable speed mtor mounted on pu coated frp blowers with aluminium powder coated impellers velocity: 100 fpm at 6 from face of the filter noise level: less than 60db at 1 meter from the face of the equipmenthepa filter grill: stainless steel grills duly perforated and polished electrical specifications: a. switches and speed controller: microprocessor controlled feather touch switch panel b. fluorescent lighting: 18 watt. c. chokes for lighting: 18 watt d. ultraviolet lighting: 1.5 feet length g15t8, 15 watt power consumption: 250 watts lighting: greater than 800 lux power supply: 230v,50hz power supply, single phase 5 amperes power cord accessories: gas burner, gas/vacuum cock ( is standard), autoclave -vertical autoclave size 14" dia x 22" ht, rating in watts 3000, capacity of 52 ltrs complete s.s with foot lifting arrangement used for sterilization under saturated steam pressure at 15psi with double walled units with inner chamber made of thick stainless steel and outer chamber made of s.s.lid is made of thick gauge stainless steel with pressure gauge steam release valve, and safety valves. with foot lifting arrangement. with s.s. basketaccessories:1. digital temperature indicator cum controller with timer -1 no.2. water level cut off-1no.3. pressure cut off switch-1no. ( is standard), digit
Tender For procurement and installation of different instruments for instrumentation of earth dam and spillway in deo irrigation project for the year 2025. - supply of fiberglass reinforced plastic (frp) make universal enterprises an improved venturi plate conformed to is: 9108 for accurate measurement of water flowing through channels comprising of masonry construction provided with pre-fabricated glass fiber lining on both sides, a side chamber provided in one side masonry wall of the said flume on the upstream side, a pipe provided at the bottom of the chamber connecting the said chamber with the water flowing through the notch, a float means provided in the said chamber, enabling recording the rising or falling level of water in the said chamber such as a scale provided in the said chamber, moulded engraved gauge marking in lit/sec and also in centimeter including moulded and engraved discharge table, capacity marking, flow direction, m.s pipe stiffeners, hold fasts, sand treatment on the backside of plate but excluding gst as per the instruction of engineer-in-charge etc. complete, inside spillway foundation gallery - 15 lit./sec. v-notch, seepage drain - 90 lit./sec. v-notch, calibration marks:- supply of polymers composites improved calibration marks make universal enterprises with contact molding process, both side finish, m.s. strip embedded inside, engraved and molded marking for bands and figures covered with radium and covered with two coats of polyurethane for surface protection with marking in reduced levels, sill, fsl, frl, mwl but excluding gst as per the instruction of engineer-in-charge etc. complete, supply vw up-lift pressure meter provision for connected to das make : aimil ltd. uplift pressure meters are used for measuring and recording of uplift pressures acting in foundations of concrete/masonry dams. vibrating wire type uplift pressure meter : range: 0.2 mpa to 5.0 mpa./7ksc accuracy: 0.5 -1 % fs. temp limit: - 10 to 70 deg c. coil resistance: 140 - 160 ohm thermistor: ysi-44005 or equivalent. material: stainless steel cable: 1m, 4-core borehole for uplift pressure meter at foundation gallery (inside spillway) should be straight from foundation level and clear. proposed location : inside spillway foundation gallery in overflow section: 7 no. non overflow section: 2 no. purpose: uplift water pressure measurement. (but excluding gst), supply automatic seepage measuring system make : aimil ltd / sysgeo italy or equivalent vibrating wire water leakage measuring systems are used for measuring water leakage and flow in dam galleries by installing v notch weir coupled with vibrating wire sensor for remote monitoring of water leakage. sensor type: sensor : vibrating wire precision water level sensor range: 300mm resolution: 0.025%fs material : stainless steel excitation : sweep or pluck assembly: v.w. type sensors enclosed in an environmental proof fibre glass box. splicing kit & adhesive required accessories. proposed location : inside spillway foundation gallery: 1 no. toe drain: 1 no. (drainage outlet) purpose: seepage water measurement in liter per second (but excluding gst), supply data logger or data acquisition system aimil make dt85g with cem20 or ace s korea analog channels 16 analog input channels each channel is independent and supports: one isolated 3-wire or 4-wire input, or two isolated 2-wire inputs, or three common referenced 2-wire inputs. expansion requires optional cem20 sampling integrates over 50/60hz line period for accuracy and noise rejection maximum sample speed: 40hz effective resolution: 18 bits linearity: 0.01% common mode rejection: >90db line series mode rejection: >35db vibrating wire frequency range: 500 to 5khz coil resistance: 50 to 200 stimulation method: single pulse pluc digital channels 8 bi-directional channels input type: 8 logic level (max 20/30v) output type: 4 with open drain fet(max: 30v, 100ma) 4 with logic output alarms power supply , sim card will be in your scope. propo