Web Analytics Made Easy - StatCounter

Mining Consultancy Service Tenders

Get complete information related to latest Mining Consultancy Service Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Mining Consultancy Service Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Mining Consultancy Service Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45475154 Due date: 07 Jul, 202607 Jul, 2026 30.00 Lacs
Tender For corrigendum : repair / replacement and maint of lt external electric supply works and other connected items at east & west wing in tech area under ge (af) tech area gwalior - s&f in repair mccb, 4 pole, 630 amps current rating and ultimate breaking capacity ics=icu =100% 36 ka with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed., all as per item here-in-before but mccb, 4 pole, 400 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 315 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 250 amps current rating and ultimate breaking capacity 36 ka. ics = 100% of icu, all as per item here-in-before but mccb, 4 pole, 160 amps current rating and ultimate breaking capacity 36 ka . ics = 100 % of icu, all as per item hereinafter but mccb, 4 pole, 125 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 100 amps current rating and ultimate breaking capacity. 16 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 63 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, m&l for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50mtrs below ground level) connected to gi strip 25 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm gi tubing medium grade and necessary fitting for protection of gi strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, pcc chamber using pcc(1:3:6) type c-1 using 20mm graded stone aggregate, rcc cover 40mm thick (1:2:4) type b-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm c/c both ways with ms handle 8mm dia, plastering 15mm thick cm (1:6) externally up to 150mm below ground level, gi funnel with 20mm dia medium grade gi pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate no.3 of ssr part-i (2009) and connected to earth test point incl testing and marking bldg nos and writing test results (in white) on a black painted m.s. plate (size 300x300x3mm th) duly welded with angle iron of size 40x40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.note :- (i) gi strip 25 4mm and gi pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing.(ii) excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) the rates quoted by the contractor are deemed to be included for pcc chamber and pcc cover as per ssr part-1.-, m&l for preparation of old painted surfaces of lt steel tubular pole/strut, of any description and in any position 9.00/8.50 mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, gi pipe bracket of street/security light, anti climbing devices etc and providing three nos radium band strips complete all as specified and directed., supplying ,laying, jointing and testing xlpe insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes.note: the cost of taking down of lt ug cable is deemed to be included in the quoted rate, 35 sqmm 3 core, 50 sqmm 3 core, 70 sqmm 3 core, 185 sqmm 3 core, 240 sqmm 3 core, excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and get

Central Government/Public Sector

CTN :45733986 Due date: 21 Jul, 202621 Jul, 2026 49.57 Lacs
Tender For special repair to building no. t-639, t-640 and t-641 at 255 rudra bde camp and building no. t-79 at 21 jat and building no. t-15 of 8 garh rif and constr of soakage pit at 21 jat under tangtse mil stn under ge 860 ews

Central Government/Public Sector

CTN :45369103 Due date: 04 Jul, 202604 Jul, 2026 20.00 Lacs
Tender For corrigendum : repair maint of gi water supply pipe line sluice valve nrv valve pit chamber at src mh mdc sho and golf area under ge ramgarh cantt

Central Government/Public Sector

CTN :45369104 Due date: 04 Jul, 202604 Jul, 2026 20.00 Lacs
Tender For corrigendum : repair maint of gi water supply pipe line sluice valve nrv valve pit chamber at prc mes asc temple lane and lekha nagar under ge ramgarh cantt

Central Government/Public Sector

CTN :45700281 Due date: 17 Jul, 202617 Jul, 2026 30.00 Lacs
Tender For repair maint of cidi pipe line various valves valve pit chamber and allied works at danapur under ge danapur cantt

Central Government/Public Sector

CTN :45713861 Due date: 18 Jul, 202618 Jul, 2026 49.50 Lacs
Tender For repair/replacement to sewage line, septic tank, soak pit, hardstanding and path under age b/r - i of ge (west) bareilly.

CTN :45700798 Due date: 01 Jul, 202601 Jul, 2026 10.00 Lacs
Tender For construction of power transformer pit and renovation of yard, repair control room at 33 kv s/s bhonawas.

CTN :45699267 Due date: 10 Jul, 202610 Jul, 2026 4.47 Lacs
Tender For repair of community compost pit csc functionality facilities repair of vermi compost unit

CTN :45699269 Due date: 10 Jul, 202610 Jul, 2026 6.01 Lacs
Tender For repair of community compost pit in karadipakkam panchayat repair of segregation shed in karadipakkam panchayat, providing pumping main line 415m from colony pump room to community hall and perumal koil in karadipakkam panchayat , providing pumping main line 560m from colony pump room to community hall in karadipakkam panchayat

State Government

CTN :45708176 Due date: 29 Jun, 202629 Jun, 2026 NA
Tender For work contract for repair, supply, and application of chemical resistant coating to neutralization pit of dm plant at wtp, paras tps.
 Loading, Please wait...

Connect us via What's Up