Get complete information related to latest Mir Machine Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Mir Machine Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Mir Machine Tenders.
Tender For technical specification point wise dbs implant & accessories - dbs rechargeable with directional lead with25yr battery life & image guided programming integrated inside clinician programmer with micc multiple independent current control technology with zero volt technology,bluetooth connectivity with clinician and patient programmers, usfda & ce approved kit contents: rechargeable pulse generator-1 , directional lead kit -2 , extension kit -2 , burr hole locking kit -2 , tunneling tool -1 , patient remote control kit -1, patient charging kit -1 , dbs rechargeable with non directional lead with 25yr battery life & image guided programming integrated inside clinician programmer micc multiple independent current control technology with zero volt technology,bluetooth connectivity with clinician and patient programmers. have 8 contact non-directional lead kit with array span of 15.5mm for maximum coverage, usfda & ce approved kit contents:rechargeable pulse generator -1, non-directional lead kit -2, extension kit -2, burr hole locking kit -2, tunneling tool -1, patient remote control kit -1, patient charging kit -1, dbs non rechargeable with directional lead with image guided programming integrated inside clinician programmer micc multiple independent current control technology &bluetooth connectivity with clinician and patient programmers,usfda & ce approved kit contents: non-rechargeable pulse generator -1 , directional lead kit -2 , extension kit -2, burr hole locking kit -2 , tunneling tool -1 , patient remote control kit -1,), dbs non rechargeable with non-directional lead with image guided programming integrated inside clinician programmermicc multiple independent current control technology withbluetooth connectivity with clinician and patient programmers. should have 8 contact non-directional lead kit with array span of 15.5mm for maximum coverage,usfda & ce approved kit contents: non-rechargeable pulse generator -1, non-directional lead 1), dbs implant kit with non-rechargeable, 3t mri compatible and sensing enabled ipg and directional leads.the implanted pulse generator (dbs neurostimulator- ipg) should have a minimum service life of 5-7 years and there should not be a need to recharge it periodically.ipg should have the capability for group programming and ability to store the programming data in ipg itself and retrieve from ipg.the system should be able to sense local field potentials (lfps) from brain targets and this data should be accessible through the physician programmer. the leads should be able to stimulate in specific directions, in addition to the ability to stimulate circumferentially. markers on leads should facilitate directional programming even if lead rotates. the leads should also be able to sense lfps.burrhole kit should be there for securing lead in place. microelectrodes for intra op stimulation and recording should be there.the extension connecting the lead and ipg should be flexiblethere should be a tunneller to place the extension wire and the tunneller should be metallic and firm to enable smooth tunnelling.the system should have approval for conditional full-body 1.5t & 3t mri compatibility.patient programmer, enabling the patient to see and if needed, modify the stimulation under guidance, should be available. patients should be able to mark dyskinesia, tremor etc. using the programmer., dbs implant kit with rechargeable, 1.5t & 3t mri compatible and sensing enabled ipg and directional leads.the implantable pulse generator (dbs neurostimulator- ipg) should have a service life of 15+ years if regularly recharged by the patient at specified intervals.ipg should have the capability for group programming and ability to store the programming data in ipg itself and retrieve from ipg.the system should be able to sense local field potentials (lfps) from brain targets and this data should be accessible through the physician programmer. the system should have fda ap
Tender For supply of purchase of various medical forms and ledgers e e - pre-op check list , hematology form , bio chemastry , ct scan , hiv form , case sheet cover , medical case sheet , consent form , spl inv form , intake out put chart , sick report book , movement order , liquor issue from , e- ticketing form , log book computer , prescription pad , usg form f g , gate entry pass form , do pad , family health questionnaire , vehicle in out register , daily veh dvr parade state register , leave application format 1 2 10 pad each , service booklet , service card civilian personnel book , form of leave account , i card register 50 pages , anaesthesia register 300 pages , general surgery register major 300 pages , gynae surgery register major minor 300pages , ot parade state register 300 pages , ot daily detailment register 300 pages , ora attendance register 300 pages , implant receiving register 300 pages , inventory ortho trauma register 300 pages , inventory ortho joint register 300 pages , inventory ortho spine register 300 pages , pac booklet , anaesthesia chart , pre anaesthesia check up form , special investigation form , pre anaesthesia check up form, anaesthesia notes ga mac , pre anaesthesia check up form, anaesthesia notes sa rab ea , intake out put chart icu , transfer check list , investigation check list , x ray inv form 100 pages , microbiology culture report register 8qr , haematology routine register 8qr , peripheral blood smear register 8qr , body fluid register 8qr , cytology register 8qr , fnac register 8qr , biopsy register 8qr , biochemistry register large , serology register 8qr , special tests register 8qr , urine routiene register 8qr , pbs reporting pads 200 pages , pap smear reporting pads 200 pages , lab duty roster 8qr , urgent sample receiving register 8qr , critical value register 8qr , medical store expendable expence register 8qr , blood bag labels for products along with blood group a b ab o including colour codes , reaction form , blood donor excuse form , blood donor questionnaire cum consent form , blood donor certificate , duty bta roster 8qr , viral marker register 8qr , master record register 8qr , daily statement register 8qr , component preparation register 8qr , sdp concent and screening pads , tkr booklet jrc , orthopeadic surgery register major , pre op screening for jrc patients , master ledger register 300 pages , parade state register officer 300 pages , offrs leave register 300 pages , key in out register 300 pages , after office hours register 100 pages , motivational register 300 pages , supply order control register 400 pages , mri examination register 500 pages , mri ct scan envelope , ct scan inv form , ct scan examination register 500 pages , usg scan examination register 500 pages , anc scan examination register 200 pages , procedure record register 200 pages , admission and discharge book , opd register phy dept //bid details 2 / 68
Tender For supply of 3 tesla mri compatible single chamber (ssir ) pacemaker with matching electrode (58 cms) and pli and magnet & fluro cover. 3 tesla mri conditional with full body scan. compatible with tined/screw-in lead. pacing mode: vvi, vvt, voo, aai, aat, aoo, ooo. pulse amplitude should be up to 7.5 v at least . auto capture or capture management algorithms. sensing assurance is an essential feature. weight around 20 gm and volume 10 cc. expected longevity to be not less than 12 yrs at 100% pacing of 2.5v, 0.4 mv, impedence 500 & electrode should be steroid electrode or coated electrode/unipolar or bipolar, tined or screwd compatible through 7f pli. *the oem must have registered office with service personnel available round the clock. warranty: all pacemakers should be covered by life time warranty (providing pacing therapy for the duration of patient's life time). [ai(2025-26) , item code no.s-62239, sl no.2014]
Tender For corrigendum : supply, installation and commissioning of mri 3t for assam medical college and hospital, dibrugarh, assam - lot 1: prices for mri3t:-, mri3t, accessories of mri3t, site preparation charges, any other charges, related services for mri3t, on-site assembly, testing and commissioning of the equipment, tools required for assembly and maintenance of the supplied equipment, operation, maintenance and service manual of the supplied equipment, lot 1: comprehensive annual maintenance charges (cmc) of the supplied equipment beyond warranty period year wise as follows for mri3t:-, cmc for year 6, cmc for year 7, cmc for year 8, cmc for year 9, cmc for year 10
Tender For supply of ssir-mp with matching electrodes, pli, magnet and fluro-cover. pacing mode: vvi, vvt, voo, aai, aat, aoo, ooo. pulse amplitude should be up to 7.5 v at least. must have rate response feature. auto capture or beat to beat capture management algorithms. sensing assurance is an essential feature. weight approx 20 gm. expected longevity to be not less than 12 yrs at 100% pacing of 2.5v, 0.4 mg, 500 & electrode should be steroid electrode or steroid coated electrode/unipolar or bipolar tined/screw depending upon the case compatible through 7f pli . device *the oem must have registered office with service personnel available round the clock. should be 3 telsa mri compatible with full body scan. *warranty: all pacemakers should be covered by life time warranty (providing pacing therapy for the duration of patient's life time). [ai(2025-26) , item code no.s-62236, sl no.2011]