Get complete information related to latest Mirror Optic Light Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Mirror Optic Light Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Mirror Optic Light Tenders.
Tender For procurement of required instruments, ph meter -digital, 4 led or lcd display, bench model, range 0-14 ph, accuracy sensitivity 0.01 ph, with automatic temperature compensation with combined glass electrode, electrode holder, 3 point calibration for ph, mv- 0 to 1999 mv, slope-90% to 110%, 220v ac operated. warranty minimum 1 year., turbidity meter-range 0-2000 ntu, resolution 0.01 ntu for 0-100 ntu, 0.1 ntu for 100 1000 ntu, 1 ntu for 1000 2000, repeatability 3%, source-projector lamp, detector-photodiode., calibration up to 3 points, including sample vials. warranty minimum 1 year., electrical conductivity/tds meter-microcontroller based electrical conductivity, digital 4 inch led or lcd display, bench model, different measuring ranges 0-20, 0-200, 0-2000, 0-20000, 0-200000 micro mho per cm, with automatic temperature compensation arrangement, resolution-0.01 micro s, accuracy 1% mid scale, conductivity cell of 0.1 cell constant, with holder and clamp, tds range 0-200ppt, ac operated. calibration upto 3 points. warranty minimum 1 year., flame photo meter-dual channel simultaneous display for both na & k, capable of measuring 4 elements with single aspiration i.e. na, k, li and ca with filters for na, k, li and ca, 3 digit, full scale sensitivity na-2 ppm, k-1 ppm, li-1ppm and ca-30 ppm, operated on lpg supply, with compressor. warranty minimum 1 year., spectro photo meter-digital visible spectro photometer, wave length range 340 to 900nm, bandwidth :10nm, wavelength accuracy : 5nm, wavelength setting through dial, wavelength readout: 5nm, photometric accuracy : 0.005 abs at 1.000 abs, photometric resolution: 0.1% t, 0.001 abs, photometric readout: 4 digit seven segment led, source: tungsten halogen lamp, grating based mono chromator with 600 lines/mm, power : 230 v, 10% 50 hz, detector: wide range silicon photoiode, sample holder : single position 10 mm cuvette holder, min. sample volume : 1 ml in 4 ml cuvette, measuring mode: automatic - % transmittance, absorbance, concentration, accessories: two glass cuvettes, temperature: capable to operate in room temperature. warranty minimum 1 year.
Tender For requirement of instruments and consumable chemicals (uv vis spectrophotometer) - fixed volume pipettes 1 ml. now, silent and effortless with textured adjustment knob for a firmer feel (thermofisher/eppordorf/brnds) alongwith 200 tips autoclavable., fixed volume pipettes 10 ml now, silent and effortless with textured adjustment knob for a firmer feel (thermofisher/eppordorf/brnds) alongwith 10 tips autoclavable, fluoride standard- 1000 ppm nist traceable with certificate make merck sigma- 500ml atleast with 2-3 years expiry date with iso: 17034, iron standard - 1000 ppm nist traceable with certificate make merck sigma- 500ml atleast with 2-3 years expiry date with iso: 17034, nitrate standard- 1000 ppm nist traceable with certificate make merck sigma- 500ml atleast with 2-3 years expiry date with iso: 17034, photometric test kit for measurement of iron fe number of tests: 100 (powder pillows) sample volume required: 10ml compatible with photometers: 0.00 - 3.00 mg/l fe atleast with 2-3 years expiry date, photometric test kit for measurement of nitrate no2 number of tests: 100 (powder pillows) sample volume required: 10ml compatible with photometers: photoflex 0.00 - 0.33 mg/l no2-n: 0.00 - 1.08 mg/l no2 atleast with 2-3 years expiry date, photometric test kit for measurement of sulfate so4 number of tests: 100 (powder pillows) sample volume required: 10ml compatible with photometers: photoflex 0 - 70 mg/l so4 atleast with 2-3 years expiry date, round 16 mm quartz cells round cuvettes, empty (16 mm diameter). (as compatiable with instrument), sulfate standard- 1000 ppm nist traceable with certificate make merck sigma- 500ml atleast with 2-3 years expiry date with iso: 17034, cmc for spectrophtometer for 2 years after completion of 3 years warranty, credit of old dr 6000 spectrophotometer (unrepaired) complete in all respect. , "us vis spectrophotometer with double beam source lamp: tungsten(visible range), typical wavelength range: 190-1100 nm, wavelength accuracy: 1 nm but not less than0.5 nm, spectral bandwidth: 2 nm but it should not be more than 4 nm, scanning speed: max 2000 nm/min (in 1 nm steps), etc. and instrument complete in all respect as per standard specifications exclusive of gst.(make: hach/ wtw-xylem/ thermo orion/ lovibond), warranty: 3 years.", 10mm 1 rectangular cuvette quartz, layer thickness 10 mm. quartz cells (as compatiable with instrument), 20mm- 1 rectangular cuvette quartz, layer thickness 20 mm. (as compatiable with instrument), 50 mm quartz cells -1 rectangular cuvette quartz, layer thickness 50 mm. (as compatible with instrument)