Web Analytics Made Easy - StatCounter

Mobile Auger Machine Tenders

Get complete information related to latest Mobile Auger Machine Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Mobile Auger Machine Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Mobile Auger Machine Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :43211371 Due date: 23 Dec, 202523 Dec, 2025 2.56 Lacs
Tender For recharge of rain water harvesting pit and flooring near portion with interlocking paver block and construction of new garbage hut in the south corner (back side) in ag audit punjab, sector-17, chandigarh. (sh: balance work of rain water pit boring / drilling and lowering and fixing vertical / horizontal pvc pipe)subwork/packages:sh: balance work of rain water pit boring boring / drilling and lowering and fixing vertical / horizontal pvc pipe)

Central Government / Public Sector

CTN :43144807 Due date: 18 Dec, 202518 Dec, 2025 NA
Tender For procurement of plant & machinery of diamond palmgur & allied products cluster sanctioned under sfurti - wide mouth steam jacketed pan, tilting type, diesel fired flat type pan, for jaggery and nolen gur concentration, semi-automatic single head piston filler for date and palm gur, filling, continuous induction sealing machine, single head rotary screw type cap sealing machine (for pet bottle), date and palm patali forming system, vacuum packing machine, double chamber, filter press, stainless steel blending tank, fitted with stirrer for neera line, transfer pump, neera pasteurizer, tube in tube system, neera packaging machine, stainless steel dice for candy, twin pulper, juice extractor by squishier, deep freez: horizontal model, automatic steam boiler, steam pipe line, weighing scale - digital display, weighing scale - digital display, stainless steel tank, stainless steel tank, autoclave-vertical, hot air oven, gravity convection, ph meter- digital, bacteriological incubator, water distillation still, single pan analytical balance, metzer binocular microscope, digital colony counter, inkjet printer, palm tree climber, tapping kit with leather belt, palmyra tapping knife, date palm tapping knife, perforated ladle, wooden scraper, metal scraper, open pan, wooden roller, neera collecting can (gi), plastic crate, manual trolley, battery operated van, sewing machine, leaf sizing machine, power press, leaf cutting dice, hand tools, lpg woven, screen printing appliances, computer set with printer, table, chair/tool, jigsaw machine, router machine, spiral lather machine, band saw machine, horizontal sander machine, circular saw machine, pillar drilling machine, thickness planer, dust collector, tack/self, drum sander, working table, hand tools, 1) gbm 13 rotary drill, ii) gss 280 ae orbital sander, iii) pof 1400ace routers, iv) gst 150 bce jigsaw, v) gks 190 circular saw, vi) gks 235 circular saw, vii) gbc 6 (35-15) bench grinder, viii) gsr 1201 drill/driver

Central Government/Public Sector

CTN :43111326 Due date: 30 Dec, 202530 Dec, 2025 NA
Tender For tender for supply of supply and installation commissiong d d -supply installation testing and commissioning of 2tr 24000 btu per hour minimum bee 3 star rated confirming to is 1392 part 2 2018 inverter type cassette split ceiling mount air conditioner having wireless remote controller led display for indoor unit motorized vertical horizontal swing controls air filters uto restart with memory features inbuilt drain pump rotary scroll hermetically sealed compressor and initial charge of eco friendly refrigerant condensor and evaporator coils of copper material suitable for operation on 230v 10 single phase 50hz ac power supply the indoor unit shall be suspended from the ceiling using threaded rods including clamps bolts nuts etc and the outdoor unit shall be mounted on floor complete as required , supply and laying of soft drawn copper refrigerant pipe of suitable size for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation including necessary brazing jointing etc as required for cassette split air conditioner as required for item no 1 , supply laying of 4c x 25 sqmm frls pvc insulated 1 1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 25 mm dia minimum thickness of 1 2mm pvc drain pipe along with accessories and necessary clamps with an u trap at the end as required , supply and fixing of 75mm dia minimum 18mm thickness pvc covering pipe using necessary bend colloc clamps threded rod supports accessories etc for laying copper refrigernt line electrical cable and drain line as required. , supply and installation of floor mounted powder coated ms 25 x 25x5mm l angle frame including clamps bolts nuts vibrating dampers as required , drilling of hole using core cutting machine of size up to 100 mm dia in concrete stone wall ceiling for laying refrigerant lines etc and finishing the same with cement mortar after laying , dismantling shifting of old 2tr cassette split air conditioner having indoor and outdoor units associated refrigerant pipes electrical wires and drain pipes including pump down of refrigerant. , making of necessary alteration of existing gypsum false ceiling for installation of cassette air conditioner indoor units including necessary aluminium channel support gypsum board necessary accessories including painting to match for the existing false ceiling , supply installation testing and commissioning of 2tr 24000 btu per hour and iseer value five star rated and compliance with is 1391 part 2 2018 wall mounted inverter type hi wall split cooling inverter air conditioner having wireless remote controller with led display hermetically sealed scroll rotary compressor and eco friendly refrigerant initial charge of refrigerant condensor and evaporator coils of copper material air filter with auto swing auto restart features suitable for operation on 230v single phase 50hz ac power supply the indoor unit shall be fixed rigidly on wall using necessary frame the outdoor unit shall be mounted on floor laying and interconnection of standard length copper refrigerant piping as supplied by the oem between indoor and outdoor units complete in all respects as required necessary drilling of hole and finishing the same to match for the surrounding as required. , supply and laying of beyond the standard length supplied by the oem copper refrigerant pipe of size suitable for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation for hi wall split air conditioner as required for item no 1 , supply laying of 4c x 25 sqmm frls pvc insulated 1 1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 75mm dia minim
 Loading, Please wait...

Connect us via What's Up