Tender For procurement of heavy duty six station multi gym equipment - heavy duty commercial grade steel, minimum 11 gauge, minimum 50 x 100 mm rectangular steel tube, minimum 3 mm, precision robotic welding, anti-rust treated, electrostatic powder coated, minimum 80 microns, lat pull down, seated row, multi press (chest / shoulder), leg extension, leg curl
Tender For bid to ras tender for supply of disconnecting ht and lt supply taking down the defective transformer indoor outdoor type from four pole two pole structure or lifting from the outdoor type foundation or taking out from sub station bldg using a crane of suitable capacity and slings ropes etc as required and shifting the same to civil workshop for repairs complete all as directed for transformer capacity 400 kva , shifting back the repaired transformer indoor outdoor type from civil workshop to site reinstalling at original position and fixing properly on four pole two pole structure or outdoor type foundation or inside a sub station bldg using a crane of suitable capacity and slings ropes etc as required making ht lt side connections and testing for satisfactorily working complete all as directed for transformer of capacity 400 kva , draining out transformer oil from the transformer and storing the same in suitable containers to be arranged by contractor without any extra cost opening the top cover and lifting up the core assembly carefully to check the condition of transformer windings and core retanking the same after repairing checking of leakage from transformer body and repairing welding works required for making transformer body leak proof refilling the transformer oil dully dehydrated and filtered dehydration and filteration to be paid separately and making all connections with ht lt side bushings refixing the top cover and testing the transformer with a suitable capacity insulation tester complete all as directed for transformer of cap 400 kva , m and l for rewinding of burnt out defective ht copper coils with new super enamelled heavy duty copper winding wires of size matching to the existing one including varnishing drying in a suitable oven and all insulating material such as cotton sleeves tapes etc and connections with bushing terminals complete all as specified and directed , all as per item no 4 above but lt copper coils complete all as specified and directed , m and l for painting the transformer tank from inside with two coats of zinc chromite after preparing the tank walls bottom top cover inner side by properly cleaning the surfaces oil free complete all as directed for transformer capacity 400 kva , m and l for replacement of defective ht porcelain bushing of suitable size for transformer of cap 400 kva including washers of good quality complete all as specified and directed , m and l for replacement of defective lt porcelain bushing of suitable size for transformer of cap 400 kva including washers of good quality complete all as specified and directed , dehydration and filteration of transformer oil for indoor outdoor type transformers of any capacity at site using transformer oil filteration plant to improve di electric strength not less than 45 kv at 2 point 5 mm electrode gap complete all as directed note unit rate quoted shall be deemed to include the charges for hiring of oil filteration plant shifting to different locations at cantt area testing of samples of oil as per requirement and nothing extra will be paid on this account , s and f new transformer oil for replacement or topping up the level of oil having dielectric strength not less than 45 complete all as specified and directed
Tender For reconstruction/repair of civil structures and laying of damaged rising main and distribution at various locations under sassci work wise details given annexure i - restoration works of jal shakti (phe) city division no.i including reconstruction / repair of civil structure and laying of damaged rising main and distribution at various locations uinder sasci (phe sector). name of works:a.restoration of rising main and washed away supports of 8" rising main in lower roop nagar. b.damage of compound wall at tibba section of sub- division dhounthly. c.constuction of main gate / barbed wire fencing / road/ wall damaged near gsr 22.50 lacs glns at lohar station. d. restoration of boundary wall, roof and floor of the pump room building at phase iind muthi pumping station. e. improvement / restoration of damage chain link fencing around intake structure at cps nai muthi. f. construction of protection work to protect tube well and pump room at muthi left and muthi 6 and muthi 7 tube well at cps nai basti. g. providing and laying damage rising main at tube well muthi left, tube well no.6 and tube well no.7 nai basti at cps nai basti. h. repairement of the tube well buildings at muthi left, muthi 6, muthi 7 and cps naibasti. i. raising of udheywala station and construction of manifold and allied works of welding at tube well no.5 udheywala and suryavanshi nagar station of sub-division muthi. j. uplifting the central pumping station samadhian by way of shifting civil, electromechanical infrastructure of sub-division dhounthly under phase 1st. k. uplifting the central pumping station samadhian by way of shifting civil, electromechanical infrastructure of sub-division dhounthly under phase 2nd. l. uplifting the central pumping station samadhian by way of shifting civil, electromechanical infrastructure of sub-division dhounthly under phase 3rd. m. construction of 200000 glns sump tank at cps samadian. n. shifting of pipe utiliies at brick klin tube well and its allied works. o. reconstruction / repairment of bath room at sub-division dhounthly and muthi. p. restore the front area by way of laying paver blocks at cps gujjar nagar. q. erection of truss over the damage roof top central pumping station cps muthi goan. r. erection of truss over the damage roof top central pumping station and dismentaling of staff qtr at station cps gujjar nagar. s. reconstruction of damage operator qtr at cps gujjar nagar under dhounthly sub-division.
Tender For supply of multi process control trainer setup for instrumentation engineering lab under mhrd scheme - purchase of multiprocess control trainer setup for instrumentation engineering lab under mhrd scheme - multiprocess control trainer set up, multiprocess control trainer set up - specifications:- setup must contain flow, pressure, level, temperature loops also derived loops like cascade and feedforward loops. temperature loop must be independent. setups consist of a circulating closed loop water plant or circulating water system including control valve, tanks, independent pumps and necessary valves including bypass valves and rotameters. using this we can be able to do flow control loop with pid,level control loop with pid,and pressure control pid, as independent experiments.the setup must include the following:1.one linear characteristics diaphragm operated control valve with 15mm stroke 1/2-inch size, type: high-capacity globe seat leakage class (as per ansi/fci 70.2).2.measuring tank with volumetric measurement scale and 1000mm level, in of 25 ltr capacity. sump tank min of 40 ltr capacity. all tanks made of ss304, with sight glass, and finished with mat steel finish.3.2 no s smart dp transmitter for flow and level measurement with hart protocol, display and keys integrated for calibration,0-1000mmh2o measurement range,0.01% accuracy, international iso certified ce approved make,24v supply,4-20ma output, loop powered.4,1nos of magnetic flowmeter with display and keys integrated for calibration,0-2000lph measurement range, read out: 0 - 100%, 4-20ma lcd display,0.05% accuracy, international iso certified ce approved make,24v supply,4-20ma output to measure flow as a independent loop.5,. smart pressure transmitter and temperature transmitters with hart protocol, display and keys integrated for calibration, pressure transmitter 0-10bar measurement range, read out: 0 - 100%, 4-20ma lcd display,0.05% accuracy, temperature transmitter 0-250 rtd type international iso certified ce approved make,24v supply,4-20ma output, loop powered.6, pressure tank of 24 liters with necessary valves for pressure loop.7.1nos orifice plate (ss304) and assembly grade with flange 1/2-inch size for flow measurement.8.2 nos pumps 0.5hp, ss centrifugal pump, minimum 1-inch pipeline of ss or high-pressure withstanding plastic with plastic welding.9. rotameters 2nos 1 inch size flow: 200-2000 l/h,ss thread, clear acrylic type.10, plc control station with 4 analogue inputs and one analogue output with necessary digital inputs and outputs to operate all loops directly from panel side.plc must have ethernet connectivity with supported protocols profinet and modbus tcpip.11.required all pneumatic components to full fill the process loops such as fr,needle valves etc.12,i to p converter 4-20ma to 3-15psi with 1/4" process connection with proper copper copper tubing.13, loop including flow pid control, level pid control, pressure pid control, cascade control (level flow), ratio control (flow flow).14.all loops can be operated using a scada system and independent pushbutton control includes trend of all analogue signals and pid tuning. scada direct profinet connectivity to plc and computer with intel i5 processor, 8gb ddr3 ram,1tb sata hdd,licenced windows 11 professional.15, required a standalone software application that must be installed on pc in which it can used to control and monitor all the functions used in scada. the application must contain process parameter trend graph plot for to study about process loops.16.the whole system setup must be in ms powder coated standalone mobile table with lockable castor wheels. all the components used be industrial. copper tubing for air connection, pressure gauges 4inches 3nos, electrical wiring connection to be flexible for to connect field devices. panel with switches, indicator, test points with banana connectors as required, multistrand wire with proper insulated lugs, ferruling & neat wire dressing & clam
Tender For virudunagar-tenkasi - kollam section:- through weld renewal (twr) by mobile flash butt welding (mbfw) at isolated locations from km:-542.000 to 623.440 for a length of 50.440 km in between virudunagar-sankarankovil station in sse/p.way/sivakasi section and from km:-623.440 to 668.000 for a length of 44.560 km in between sankarankovil-sengottai stations in sse/p.way/sengottai section.
Tender For annual work contract for maintaining welding local sub distribution boards, welding points including short shutdowns or aoh /coh at nashik thermal power station.
Tender For supply of welding electrodes for dhauliganga power station c c - ss welding electrode e 309 mo15 4 mm , ss welding electrode e 309 mo15 , ms welding electode e 7018 low hydrogen 4 mm into 450mm , ms welding electode e 7018 low hydrogen 3 point 15 mm into 450 mm , ms welding electode e7018 low hydrogen 2 and half mm into 450 mm , ss welding electrode e 309 mo 15 2 and half mm