Web Analytics Made Easy - StatCounter

Modbus Gateway Tenders

Get complete information related to latest Modbus Gateway Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Modbus Gateway Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Modbus Gateway Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45430081 Due date: 19 Jun, 202619 Jun, 2026 NA
Tender For corrigendum : procurement of da0830000099 - 4 port modbus gateway on rate contract basis for one-year.

Central Government / Public Sector

CTN :45515896 Due date: 10 Jul, 202610 Jul, 2026 NA
Tender For auction sale of ewaste, e-waste, e-waste (v2) - forward auction for disposal of obsolete it hardware such as desktops, laptops, servers, printers, networking equipment, and other it peripherals lying at indian oil corporation limited, gujarat state office based location (sidhpur terminal, vadodara black oil terminal, gri koyali, sanand bottling plant & gujarat state office).

Central Government And Public Sector

CTN :45430011 Due date: 11 Jun, 202611 Jun, 2026 NA
Tender For auction sale of others - total qty.= 743 nos., description: - voice card-18 nos., dtmf-33 nos., web fill mux psu card-10 nos., tributary card-6 nos., pd mux card-32 nos., exchange card-13 nos., psu card of puncom mux-4 nos., amplifier 250 watt-3 nos., pole for cgdb-16 nos., base of pole for cgdb-21 nos., cap of cgdb-14 nos., pd mux-5 nos., m.s. truf w/o cap 2 mtr long-14 nos., horn speaker-6 nos., cgdb-2 nos., smps battery charger 48v-2 nos., lan extender-14 nos., smr statcon-2 nos., c.t. box 20 pair-5 nos., c.t. box 50 pair-4 nos., power supply unit-11 nos., control telephone-65 nos., magneto telephone-175 nos., auto telephone-69 nos., modem-49 nos., power supply unit for vhf-3 nos., dtmf box (empty)-40 nos., head qtr equipment-7 nos., empty acid jar-3 nos., 9u rack-1 no., u-link panel-4 nos., switch-6 nos., coral mux-1 no., statical mux-4 nos., networking terminal server-1 no., emergency portable t/p-11 nos., megaphone-1 no., voice data loger-3 nos., voltage regulator-1 no., puncom charger-1 no., fare display board-3 nos., router cisco-1 no., umbrella-1 no., smps power plant-1 no., zyxel communication wifi router-9 nos., 10 mm ms rod-5 nos., pipe rod-6 nos., coaxial cable-7 nos., tweezer-2 nos., cutter-1 no., screw driver 801-1 no., adjustable spanner-1 no., adjustable spanner 205mm-4 nos., lock pad 75 mm ig-2 nos., screw driver 925-1 no., combination plier-1 no., insertion tool (krone)-5 nos., jointer tool kit with 25 items-2 nos., digital multimeter 15s-3 nos., digital multimeter 18s-2 nos., analog han driven (megger)-1 no., digital multimeter 3&1/2 digit fluke-1 no., automatic dispenser machine-1 no., electric spray sanitiser machine-1 no., digital multimeter (flike-287)-1 no.(remarks - material to be sold on as is where is basis and will be delivered in numbers).

Central Government/Public Sector

CTN :45114129 Due date: 22 May, 202622 May, 2026 25.00 Lacs
Tender For tender for supply of sitc and maintenance of addressable fire alarm and detection system at uco bank - supplying , installing , testing and commissioning approved make microprocessor based multi-loop , networkable addressable 02 loop fire alarm control panel with minimum 10 inch 1024x600 resolution lcd with touch capability , including audible and visible feedback , backlit by a long life , solid-state lcd. it shall also include a full qwerty-style keypad on the color , touchscreen display. the display shall have the ability to scroll events by type (i.e. fire alarm , supervisory alarm , trouble , etc) using the touchscreen with customizable buttons , 10000 history events & autolearn feature for programming. the system can be supported upto 2000 generation zone & 2000 logic zone & 50 releasing zone. the panels in network having true peer to peer provision. the panel shall have provision to support up to 50 releasing zones to protect against 50 independent hazards.the panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop and shall be extendable upto 10 loops. , supplying , installing , testing and commissioning approved make modbus interface gateway for communication with bms / other utilities. modbus shall support supports reads of up to 100 registers at a time. modbus gateway shall act as an independent node communicating on the peer to peer network and shall not be dependent on the fire panel cpu for operation. modbus over tcp/ip , meets ul 864 , 10th edition requirements , supports two modbus masters & monitored 10 cpu nodes . failure of fire panel cpu shall not result in failure of modbus gateway. the gateway card shall be ul listed , the mimic annunciator for the fire alarm control panels (facp). this provides the facp with remote , serially-connected display. a five inch touchscreen display provides system status , point information , and event counters. the display shows two events simultaneously , and pages through up to 50 of the highest priority events in the system. the remote display also provides system control with six programmable softtouch buttons as well as acknowledge , silence , reset and drill. , supplying , installing , testing and commissioning approved make addressable multi-criteria photo-thermal detector with sensitivity range of 0.5 to 4.0% obs/ft.the intelligent multi criteria detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. it shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. the detector shall have twin bi-colour led for 360 deg viewing. addressing shall be with user friendly rotary decimal switches. detectors having base addressing must provide protective cap. detectors with soft addressing must provide programming tool. the detector sensitivity (day & night) shall be controlled from the panel to get accustomed to the local environment. the detector shall be ul listed & fm approved. , supply , installation , testing and commissioning addressable self-test multi-criteria photo-thermal detector with sensitivity range of 0.5 %/ft to 4.0 %/ft obs. intelligent multi criteria detection device shall include the ability to combine signal of the thermal sensor with photoelectric signal in an effort to react hastily in the event of a fire situation. , supplying , installing , testing and commissioning approved make addressable manual call point ( break glass type). the device shall have an led which shall blink in normal state & get steady on activation to monitor the heath status of the device. the device shall be ul listed & fm approved. , supplying , installing , testing and commi

corporations/Associations/Others

CTN :44853964 Due date: 23 Apr, 202623 Apr, 2026 NA
Tender For auction sale of networking equipments and servers - lot 2,electrical & electronic items - lot 4a,electrical & electronic items - lot 4b,electrical & electronic items - lot 4c,electrical & electronic items - lot 4d,cell phones & accessories - lot 5a,cell phones & accessories - lot 5b,machinery and spare parts - lot 6a,machinery and spare parts - lot 6b,machinery and spare parts - lot 6c,machinery and spare parts - lot 6d,machinery & spare parts - lot 6e,machinery & spare parts - lot 6f,medical equipment - lot 7a,medical equipment - lot 7b,miscellaneous - lot 10a,miscellaneous - lot 10b,miscellaneous - lot 10c,miscellaneous - lot 10d,miscellaneous - lot 10e
 Loading, Please wait...

Connect us via What's Up