Get complete information related to latest Modular Switch Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Modular Switch Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Modular Switch Tenders.
Tender For temperature switch, for mfi machines. part no.: twr3/4mo/80 grad c/aus , make- plasser hsn- 903210 warranty: 06 months from the date of supply. note: the above item description as per rdso policy on procurement of spares of track machine dated 08.08.2025. [ warranty period: 6 months after the date of delivery ] ]
Tender For supply of modularswitch box consist of 4 nos. of 6 amps modularswitches and 2 nos. 6/16 amps 5 pin modular socket complete with modular face plate and box. all switches and sockets shall be isi marked. the box shall be made up of pvc or abs material and switcble for wall mounting type. the switches and sockets are comfoming to is 3854 & is 1293 or latest. ]
Tender For supply of set of spares for m/s. sidwal make roof mounted cab ac for 3 phase locomotive, set consists of 04 items as given below : roof mounted cab ac specification rdso/2007/el/spec/0055 rev 2. 1) return air filter part no sr-4371-50 nos. 2.) cable mounted socket part no sr-4372-20 nos. 3) cable mounted plug part no sr-4373-20 nos4.) change over switch /selector switch part no sr-4375-25 nos. make: sidwal only. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For repair replacement of internal wiring incl sub main wiring, mcb dbs, bldgs security lights and connected items in pocket 1 to 8 under ge roorkee - taking down old unserviceable point wiring of any description including all fittings and fixtures like switches, sockets, ceiling rose, fan regulator, tubelight,, mirror light,, ceiling light etc complete all as specified and directed., m&l for point wiring with 1.5 sqmm frls-h insulated, unsheathed, multistranded, 1100 volts grade copper conductor cable single core conforming to is:694 along with one run of 1.5 sqmm frls-h insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories / junction boxes / inspection covers etc of suitable size but not less than 20mm(od), concealed in wall/ floor etc including provision of earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass gi screws/ modular cover plate as required for mounting switches, sockets, fan regulator, etc. / modular metal flush box covered with modular frame plate with cover of any size as per site requirement for mounting modularswitches, modular sockets, modular fan regulator etc complete all as specified and directed for one light / ceiling fan / exhaust fan / call bell point controlled by one switch, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., all as per item no 2 here-in-before but one wiring in existing conduit for one light / ceiling fan / exhaust fan / call bell point controlled by one switch., all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one one light point controlled by two no. two way switch complete all as specified and directed, all as per item no. 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., m&l for sub main wiring along with earth wire with frls-h insulated copper conductor, single core cable drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 25mm concealed in wall/ floor etc including taking down existing unserviceable sub main wiring of any description complete all as specified and directed for 2runs x 4 sqmm(ph & n) + 1run x 4 sqmm(earth wire):- (note: three runs of copper cable and one run of pvc conduit shall be measured as one unit length), all as per item no 11 here-in-before but 2runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), all as per item no 11 here-in-before but 2runs x 10 sqmm(ph & n) + 1run x 10 sqmm(earth wire), all as per item no 11 here-in-before but 4runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), notes for item no. 2.00 to 14.00(i) quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface.(ii) if any beam / column / rock wall is encountered while cutting chases, that particular portion may be provided with pvc casing & capping or surface conduit for drawing cables and surface pvc gang box fully enclosed type for mounting switches, sockets & regulators etc to avoid any damage to the structure. (iii) no cutting shall be done on ceiling for laying pvc conduit for ceiling fan point wiring. surface conduit or pvc casing capping may be
Tender For repair/maintenance of diesel generator set with central panel and other connected items at zone 5 and 1(a,b,c) zone 1, 3 (a and b), zone 2 and zone 4 under ge (s) tezpur - maint and servicing of dg set 320-400 kva conopy type with amf panel (if installed ), through authorise service agency of oem , including replacment of defective/wornout parts with new spares such as filters, gaskets, v belts, engine oil, coolant for radiator rubber hoses with clamps, nuts bolts and cleaning of alternator with vaccum cleaner , including greasing of bearings of engine and alternator, tappet setting, checking of batteries, adding distilled water and cleaning of pol tank and radiator etc complete all as specified and directed.note:- 1. spares required for above maint will be measured and paid separately under relevent items of schedule. 2. all breakdown calls should be attended., all as per item no-1 above but for dg set of capacity 180-250 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 125-160 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 40-100 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 10-35 kva complete all as specified and directed, supply only fuel filter for 300-400 kva dg set, complete all as specified and directed, supply only fuel filter for 125-250 kva dg set,complete all as specified and directed complete all as specified and directed, supply only fuel filter for 10-100 kva dg set,complete all as specified and directed, supply only lub oil filter for 300-400 kva dg set,complete all as specified and directed, supply only lub oil filter for 125-250 kva dg set,complete all as specified and directed, supply only lub oil filter for 10-100 kva dg set,complete all as specified and directed, supply only air cleaner filter ( inner and outer ) for 300-400 kva dg set, complete all as specified and directed, supply only air cleaner filter (inner and outer ) for 125-250 kva dg set,complete all as specified and directed, supply only air cleaner filter (inner and outer ) for 10-100 kva dg set,complete all as specified and directed, supply only bypass filter for 300-400 kva dg set, complete all as specified and directed, supply only bypass filter for 125-250 kva dg set,complete all as specified and directed, supply only bypass filter for 10-100 kva dg set,complete all as specified and directed, supply only v belt for 300-400 kva dg set, complete all as specified and directed, supply only v belt for 125-250 kva dg set, complete all as specified and directed, supply only v belt for 10-100 kva dg set, complete all as specified and directed, supply only coolant for radiators complete all as specified and directed., supply only engine oil multi grade 15w40 complete all as specified and directed., s & f in repair display control panel ( base card) for 10 to 100 kva dg set complete all as specified and directed ., s & f in repair display control panel (base card) for 125 to 250 kva dg set complete all as specified and directed., s & f in repair display control panel (base card) for 300 to 400 kva dg set complete all as specified and directed., s & f in repair fuel actuator with o ring for 300 to 400 kva dg set complete all as specified and directed., s & f in repair key switch for 10 to 400kva dg set complete all as specified and directed., s & f in repair coolant temperature sensor (coolent control safety) for 10 to 400kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 10 to 100 kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 125 to 250 kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 300 to 400kva dg set complete all as specified and directed., s & f in rep
Tender For special repair to dbs sub main wiring and miscellaneous items at mh and central institute at old amritsar cantt - taking down copper/ aluminium point wiring (light, fan, socket or power) complete including fixture and fitting such as switches, ceiling roses, pendants, regulators, sockets etc, removing materials to store for keeping in safe custody or for taking credit (creit for above items shall be made as per condtitions separately) and making good disturbed surface of walls, floors, etc complete all as specified and directed., material and labour for point wiring in existing conduit for following point controlled by one switch ( using red,black,green colour wires as colour codings) complete with 1.5 sqmm ( nominal cross section area ) single core frls pvc insulated unsheathed and multi stranded copper conductor cable 1100 volt ( isi marked ) drawn through and existing pvc concealed/conduit with all fittings and accessories including pressed steel powder coated sunken terminal box suitable for modularswitch socket ( min 50mm deep and 1.6 mm thick sheet ,suitable size ) concealed in wall , including inner and outer plates ( cover plate ) suitable for fixing the modularswitches/sockets/regulator etc including provn of 1.5 sqmm single core frls pvc insulated multi stranded copper conductor wire continues as earth wire connected to earth dolly etc including necessary cutting chases in wall and making good disturbed surfaces of walls/ceiling/floorsetc by using cement mortar (1:3) complete all as specified and as directed. note : 1 switch, socket, regulator, bell, ceiling rose, regulator, lamp holder will be measured and paid separately.a) for one light /fan/ buzzer point controlled by one 5 amp switch one way, b). for one three pin socket outlet 5 amps independent board., c) for one three pin 5 amps socket outlet on the same board with other switch, d) for one light point controlled by two way switch, all a per item no 2 here-in-above but with 2.5 sq mm size cable multi stranded frls copper wire unsheathed for one 3 pin socket outlet 15 amps on independent board including continuous earth wire of pvc insulated 2.5 sq mm copper multi stranded conductor connecting to common earth dolly complete all as specified and directed., material and labour for surface point wiring for one light point/fan point/bell point controlled by one switch ( using red,black,green colour wires as colour codings) complete with 1.5 sqmm ( nominal cross section area ) single core frls pvc insulated unsheathed and multi stranded copper conductor cable 1100 volt ( isi marked ) drawn and including surface pvc conduit with all fittings and accessories i.e. pipe bend,pipe hook, elbow,juction boxes etc including pressed steel powder coated sunken terminal box suitable for modularswitch socket ( min 50mm deep and 1.6 mm thick sheet ,suitable size ) concealed in wall , including inner and outer plates ( cover plate ) suitable for fixing the modularswitches/sockets/regulator etc including provn of 1.5 sqmm single core frls pvc insulated multi stranded copper conductor wire continues as earth wire connected to earth dolly etc including necessary cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc by using cement mortar (1:3) complete all as specified and as directed. note : 1. switche, socket, regulator, ceiling rose, bell, lamp holder will be measured and paid separatelya) for one light /fan/ buzzer point controlled by one 5 amp switch one way, b). for one three pin socket outlet 5 amps independent board, c) for one three pin 5 amps socket outlet on the same board with other switches, d) for one light point controlled by two way switch, all a per item no 7 here-in-above but with 2.5 sq mm size cable multi stranded frls copper wire unsheathed for one 3 pin socket outlet 15 amps on independent board including continuous earth wire of pvc insulated 2.5 sq mm copper solid conductor connecting to common earth dolly complete all as sp
Tender For procurement of cni spares for blue star chillers lcw2 at brbcl - si board,cdco-w040-01,bluestar, mcs control board,cdco-w039-01,bluestar, current transformer,elct-000001-00, smps,elcp-w011-01,bluestar, oil level switch,elot-t020-00,blue star, phase reversal unit,elsp-w001-00, magnum display,bluestar,mcs controller, exp vv seh-175,rcexv-she 175-00,bluestar, timer,3rp15761np30,bluestar, elct expansion valve,rcexv-000000 2-00, oil heater,3101-1052c,bluestar, motor protection dev,ach4405-81,bluestar, temperature sensor,mcs-t100-402, pressure sensor,spps-t004-00,blue star, pressure sensor,mcs-ti-200f-20,blue star, load solenoid valve,rcsl-evr25-00, coil,rcsc-0000001-00,blue star, solenoid valve,rcsl-10001-00,blue star, solenoid coil,rcsc-evr3-00,blue star, control transformer,eatdz0020,blue star
Tender For notice inviting tender (nit) for supply of spares as per details enclosed for bhel-pser, 1x120 mw, iel, ph-7, sakchi, jamshedpur, jharkhand. -limit switch gear assembly