Get complete information related to latest Mogul Socket Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Mogul Socket Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Mogul Socket Tenders.
Tender For corrigendum : empanelment of agencies for supply of laboratory instruments for various water testing laboratories under jal jeevan mission, assam - ion meter with electrode and accessories for fluoridemeter: ph/ise benchtop meter with electrode stable, universal power adapter, literature, pc cable, meter test certificate electrode: ionplus fluoride and nitrate combination ion selective electrode, 1m cable, waterproof bnc benchtop ion meter (ise) along with fluoride, nitrate #electrode range: -2.000 to 20.000 resolution 0.1, 0.01, 0.001 relative accuracy 0.002 calibration points up to 5 calibration editing yes #mv/ rmv orp range 2500.0 mv resolution 0.1 relative accuracy 0.2 mv or 0.05 % of reading whichever is greater eh orp mode yes ise range 0 to 19999 resolution up to 3 significant digits relative accuracy 0.2 mv or 0.05 % of reading whichever is greater units ppm, m, mg/l, %, ppb, none calibration points up to 5 calibration editing yes calibration features timed end point, linear point to point, non-linear selectable auto-blank, low concentration range stability #temperature range -5 to 105 c, 23 to 221 f resolution 0.1 relative accuracy 0.1 offset calibration 1-point datalogging memory 2000 with time and date stamp log function manual, ready (include auto-read ), timed log edit delete individual points, group of points or all inputs ph electrode bnc, reference pin atc probe 8-pin mini-din #output rs232, usb power ac adapter included universal, 100-240 vac battery power optional 4 aas battery life 800 hrs, fluoride electrode of ion metersame make that of the ion meter, manifold filtration assembly* wide range of pumps and filtration flasks * high quality components * easily exchangeable elements *maintenance-free * low noise * added filters for enhanced pump longevity * filtration base with silicon stopper, cap & aluminium clamp connecting silicon tube technical specification for filtration flask set # high-pressure resistant tube # fiberglass filter membranes (47mm / 0.1 m) # ptfe disc filter #normal liquid filtration * specification for filtration glass set #suction bottle capacity(ml) 1000 ml # filter diameter(mm) 47/50 mm # * specification for filter flask * material: statinless steel 304, capacity: 300 ml (100 ml each) [ unit should consist of 3 flask so that 3 sample can be filtered simultanelously without any issue] # effective filtration area(cm2) = 9.6 cm2, outlet connector(mm) = 8 mm * specification for vaccum flask: #flow rate of the pump(l/min) = 17 l/minultimate vacuum(mbar) = 150 mbar # oil free, maintainance free, built in thermal protection to shut off when over heated., auto cut heater for distill water plant so that when water level decreases the heater is switch off automatically, voltage stabilizer capacity- 3 kva servo stabilizer 5 star rating, heating mantle (single station) should have digital energy regulator with multiple step power regulation automatic spill detection and saftey shutdown in built precision temperature control technial specification: flask capacity 250 ml, working temp range: ambiant + 5 to 420 degree celcius. accuracy: plus minus 1.0 degree celcius, power consumption : 150 w, heating mantle (combined unit) material of construction heating block: made with grade epoxy painted chemical resistant coating, aluminum block with 6 thermo wells for processing 6 different samples at a time. #racks: ss 316 # glassware: teflon coated # temperature range ambient + 10 deg c to 450 deg c # stability of temperature better than 0.5 deg c # controller consist of digital read out of temperature and time with 4 programmable ramps for each method. # number of programmable methods 20 numbers. # heating powers 1000w # heating position minimum 6 position # digestion time range -1 to 999 minutes # the system should have facility of acoustic signal at the end of completion of cycle to notify the operator. # the thermal digestion unit should have high thermal homogeneity # the setup should have small f
Tender For procurement of electrical materials for 5th floor classroom expansion,nims,hyderabad - supply and transportation of 20w +/-10%, >/ 2000 lumens, 1200mm length led retro tube light, housing made with alluminium anodised body, wide operating voltage with double side connection, pf?0.9, surge protection: > 2kv, thd<15%, with inbuilt driver and frosted cover cct: 3000k -6500k as desired by the department and as per is specifications, minimum cri?80,.etccomplete with 5 years warranty with bis, 1060 elec- 5.1.1 supply, transportation of energy efficient fan,1200 mm sweep, aluminium body, consuming, 28 w, bee 5 star rated, ceiling fan with brush, less direct current (bldc) motor, class of, insulation: b, 3 no's blades, 30 cm long down, rod, 2 no's canopies, shackle'kit, copper, winding, power factor greater than 0.90,, service value (cmmav) greater than 8.0, air, delivery minimum 235 cmm, 350 rpm(, tolerance as per is:374-2019), thd less than, 10%. with remote or compatible to electronic, step type regulator unit for speed control and, all remaining accessories including safety pin,, nut bolts, washers, temperature, rise=75c(max), insulation resistance more, than 2 mega ohm, suitable for 230v, 50 hz,, single phase ac supply, earthing etc., including, all standard accessories etc., complete., makes : atomberg (efficio ) / havells / orient /, halonix / crompton, 1 no 3085.00, elec-5.1.16 supply of ------------------------, 900 rpm heavy, duty exhaust fan with metallic blades., makes : crompton / almonard / havells turbo, force sp., 1078 a 12" (300mm) 1 no 3410.00, 1844 elec-, 10.1.20, 12 / 15 ms plain rod fan hook 1 no 44.00, 1853 elec-, 10.1.29, tw / pvc round blocks 1 no 9.00, elec-1.9.1 supply of --------------------------------------, makes : legrand arteor / schneider zen celo 339 a 6 / 10a 1 way 1 module modular switch 1 no 130.00, elec-1.9.1 supply of --------------------------------------, makes : legrand arteor / schneider zen celo 342 d 6 / 10a 3/2 pin 2 module modular socket with shutter.1 no 195.00, elec-1.9.1 supply of --------------------------------------, makes : legrand arteor / schneider zen celo 346 h 16a / 20a 1 way 1 module modular switch. 1 no 170.00, elec-1.9.1 supply of --------------------------------------, makes : legrand arteor / schneider zen celo 350 l 16a / 6a 1 way 2 module combi socket modular socket with shutter.1 no 270.00, elec-1.5.1 supply of --------------------frlsh / hffr pvc insulated 1100v grade as per is:694 / 2010, is17048 specification for copper cable.makes : finolex / rr kabel / havells 155 a 1.5 sqmm 100 mtrs 2410.00, elec-1.5.1 supply of --------------------frlsh / hffr pvc insulated 1100v grade as per is:694 / 2010, is17048 specification for copper cable.makes : finolex / rr kabel / havells 156 b 2.5 sqmm 100 mtrs 3900.00, elec-1.5.1 supply of --------------------frlsh / hffr pvc insulated 1100v grade as per is:694 / 2010, is17048 specification for copper cable.makes : finolex / rr kabel / havells 157 c 4.0 sqmm 100 mtrs 5950.00, elec-1.5.1 supply of --------------------frlsh / hffr pvc insulated 1100v grade as per is:694 / 2010, is17048 specification for copper cable.makes : finolex / rr kabel / havells 159 e 10.0 sqmm 100 mtrs 14535.00, supply of --708 d (8+24) 8 way tpn db horizontal with ip 43,, 24 nos--- protection as per is:13032 and suitable for ---------------s.p. out goings and for 1 no 4 pole incomer (fp isolator / mcb) with 100 a tinned copper busbar, neutral bar, earth bar and cable ties for cable management, fully shrouded neutral bar,profile blanking modules for unused mcbways, din bars and detachable gland plate etc complete with inter connections.makes : legrand / schneider /, 1 no 7560.00, elec-1.2.5 supply of --------------- width and height casing and caping with all accessories such as ts,bends, elbows etc., complete for finished item, of work.makes : modi with isi 76 b 25mm x 12 mm and thickness 1.2 mm 1 mtr 40.00, elec-1.2.5 supply of --------------- width and heigh
Tender For supply of over voltage protection (ovp) testing unit for 25 kw rrus and errus of ac coaches as per rdso smi no. rdso/pe/smi/tl/00 47-2013 (rev.0) and camtech hand book no: camtech/e/ep-02/2019-20/ovp/1.0 july- 2019 for in-situ testing of over voltage protection. [ warranty period: 30 months after the date of delivery ]
Tender For supply of led based driver and assistant desk illumination lamp as per clw specn. no. clw/es/3/0042 alt.d. technical specification: 1) operating voltage 18 to 30 v dc, with normal voltage of 24 vdc. 2) high and low glow switch has to be provided.3) the lamp unit shall have inbuilt reverse polarity, over voltage tri p, spike and surge protection.4) mechanically the housing shall be as per clw spec. no. clw/es/3/0042. al t.d [ warranty period: 30 months after the date of delivery ]
Tender For supply of set of spares for hmtd make rectifier-cum-regulator of capacity 25kw, 130v, type mar-25-130 to m/s. hmtd, taloja, as per the following list: 1) magnetic amplifier part no. c-25020 - qty. 02 nos. 2) over voltage protection unit (ovp) part no. c-25023 - qty. 04 n os. 3) current transformer assembly part no. c-25016 - qty. 02 nos. 4) printed circuit boa rd part no. c-25019 - qty. 03 nos. 5) auxiliary diode and zener diode assly. part no. c-2501 5 - qty. 01 no. [ warranty period: 30 months after the date of delivery ]
Tender For supply of 100 a protected poles: 4 pole, 18 ka mccb, rated current (in)100a , user value rated opera tional voltage (ue ):415v / 440v ac, rated insulation voltage (uj ):440v ac, rated impulse withstand volta ge (uimp):5 ,kv, rated frequency:50 hz, rated short-circuit capacity (lcn):18 ka, instantaneous tripping cur rent: c-type, each circuit-breaker shall be marked as per is 60947.2.2003, protection type - l for overload p rotection (thermal) & i for short-circuit protection (magnetic), adjustable thermal-magnetic trip and protecti on unit, fixed magnetic settings and with toggle control. [ warranty period: 30 months after the date of d elivery ]
Tender For supply of over voltage protection (ovp) testing unit for 25 kw rrus and errus of ac coaches as per rdso smi no. rdso/pe/smi/tl/00 47-2013 (rev.0) and camtech hand book no: camtech/e/ep-02/2019-20/ovp/1.0 july- 2019 for in-situ testing of over voltage protection. [ warranty period: 30 months after the date of delivery ]
Tender For supply of 250ma for mhs, maithon, dvc , potentiometer for manual voltage adjustment 10k ohm_3w for phps, panchet, dvc , potentiometer for manual voltage adjustment 10k ohm_3w for mhs, maithon, dvc , sync. transformer for scr controller unit for 150a float-cum-boost charger, 0-270- 300v_80-0-80v, 100ma for phps, panchet, dvc , sync. transformer for scr controller unit for 150a float-cum- boost charger, 0-270-300v_80-0-80v, 100ma for mhs, maithon, dvc , filter capacitor, 4700 micro farad_ 350 volt dc for phps, panchet, dvc , filter capacitor, 4700 micro farad_ 350 volt dc for mhs, maithon, dvc , blocking diode for battery charger for phps, panchet, dvc , blocking diode for battery charger for mhs, maithon, dvc , ac supply fail relay card static type 415v ac for phps, panchet, dvc , ac supply fail relay card static type 415v ac for mhs, maithon, dvc , semiconductor protection fuse, high speed, 200a for phps, panchet, dvc , semiconductor protection fuse, high speed, 200a for mhs, maithon, dvc , thyristor 150a, 1200v _h150tb12 for phps, panchet, dvc , thyristor 150a, 1200v _ h150tb12 for mhs, maithon, dvc , battery protection fuse _200 a hrc type for phps, panchet, dvc , battery protection fuse _200 a hrc type for mhs, maithon, dvc , dc voltmeter selector switch _16a, 1pole, 4 way spa3116d for phps, panchet, dvc , dc voltmeter selector switch _16a, 1pole, 4 way spa3116d for mhs, maithon, dvc , integrated dc sensing module consisting of circuit - ch. failure, dcu_ovr, befr, fbcor, sfr, auto equalise for phps, panchet, dvc , integrated dc sensing module consisting of circuit - ch. failure, dcu_ovr, befr, fbcor, sfr, auto equalise for mhs, maithon, dvc , dc power supply for idsr card _static type, 24 v and 12 v dc for 150a float cum boost charger _make_ chloride for phps, panchet, dvc , dc power supply for idsr card _static type, 24 v and 12 v dc for 150a float cum boost charger _make_ chloride for mhs, maithon, dvc
Tender For spares of boiler i.e. micro limit switch, solenoid for oil gun etc. - supply of spares for boiler i.e. micro limit switch, solenoid for oil gun etc. as per nit annexure-i, micro limit switch contact type spdt, roller lever, screw terminal , z15gw22-b 15a 125, 250 or 480 v ac, magnetic limit switch 2 wire voltage rating dc/ac 5-240 v , 100ma , 10 w , 2meters cable, solenoid for ignitor : single coil valve 5/2 way , 5 port 2 position , 4v 210-08, pressure 0.15-0.8 mpa , coil voltage 220 v ac , media air , size 1/4 inch., solenoid for oil gun : double coil valve 5/2 way , 5 port 2 position , 4v 220-08, pressure 0.15-0.8 mpa , coil voltage 220 v ac , media air , size 1/4 inch., solenoid for oil /purging/ atomising valve : single coil valve 5/2 way , 5 port 2 position , 4v 310-08, pressure 0.15-0.8 mpa , coil voltage 220 v ac , media air , size 1/4 inch., air filter regulater unit media : air , adjustment : knob type / nut type, input /output port size : 1/4 npt (f) , pressure range : 0-10 kg/cm2, manual drain with pressure gauge (0-8) kg/cm2, metal bowl seal : nbr, filter rating : 5um, filter material : sintered bronze, power contactor , coil rating 230v ac, pole : 3 , make : schneider electric, model lc1d09 , current rating : 9a, voltage rating : 415v, feedback positioner ffnb-5420 make : moniteur watchman, power relay make : idec model :ru4s-a220, voltage rating 220/240 ac, current rating 6a, contact arrangement 4pdt, contact 6a, 30 vdc, ru series 14 pin, power relay make : idec model :ru2s-a220, voltage rating 220/240 ac, current rating 6a, 8 pin, position transmitter 2 wire contactless , input angle range : 0 to 90 degree , output 4-20ma dc, operating power supply 10 v dc to 60 v dc , ingress protection ip67, operating temperature 0 to 80 degree, i/p converter input 4-20 ma, output : 0.2 to 1 bar , supply pressure 1.4+/-0.1 bar, air capacity > 5kg/h, pneumatic connection 1/8 npt for air supply and output. electrical connection: 2 pole screw terminal for 2.5 mm2 model : teip/v18311h-1121101. make abb, limit switch return v04, part id v04-11-4 make : clyde bergemann, limit switchmake: clyde bergemann. z4v10h-336-11z-1593-6 , part id : e0000093, continuous rating heavy duty industrial panel fan with finger guard accessory , operating rating 220vac , fan diameter 4" make : nisiki/ rexnord /delta
Tender For supply of mpcb (motor protection circuit breaker), current rating: 3-4a, thermal release range: 2.5-4 a, class:10, breaking capacity: 50ka, pole: 3p, voltage: 415v ac, 1no+1nc auxiliary contact block. as per sr no. 74 of bill of material (bom) of rdso specification no. rdso/pe/spec/ac/0184-2015(rev.0) & conforming to rdso spec no rdso/pe/spec/ac/0184 -2015 (re v. 0) suitable for use in ventilation fan unit. rdso approved make only. [ warranty period: 30 months after the date of delivery ]