Tender For purchase of lab equipment item for material testing laboratory as per nabl norms. - electronic balance 200 gm, accuracy 0.001 gm, standard weight box (stainless steel) 1 mg to 200 gm, variable flow type air permeability apparatus (blaine type)variable flow type air permeability apparatus (blaine type), whatman filter paper 40 (pkt. of 100 pcs), digital thermo hygrometer, mercury, stop watch digital 1/10 sec, electronic balance 1 kg capacity, graduated cylinder, length comparator, shrinkage bar mould (single), humidity chamber (heating), cement autoclave, le-chatelier water bath, steel scale 300 mm, le-chatelier mould, vicat apparatus with dashpot, vicat mould, electronic balance 6 kg 0.5gm readability., poking rod for cement, cube mould (70.6 mm), standard sand grade-i (25 kg bag), standard sand grade-ii (25 kg bag), standard sand grade-iii (25 kg bag), vibrating machine, automatic compression testing machine 500 kn, accelerated curing tank , gauging trowel, electronic balance 15 kg, cube mould (150 mm), automatic compression testing machine 2000 kn, vernier caliper digital 300 mm, measuring scale 300 mm, hot air oven 450 x 450x 450mm., water bath (28 ltr), electronic balance 10 kg capacity 1gm readability., concrete test hammer 10-100 proceq, anvil for concrete test hammer., ultrasonic pulse velocity apparatus, half cell potentiometer (rebar corrosion detector)
Tender For shifting of existing s&t gears such as buried cables, ofc, location boxes, and lc gate equipment for removal of infringements and dismantle with clearing site to facilitate earthwork and bridge work in connection with quadruoling project between vadodara to godhra work and "design, supply, installation, alteration, testing and commissioning of hot standby electronic interlocking (hitachi make) system and outdoor signaling systems in connection with track circuiting work at sevaliya station for wtps siding under dy. cste construction, vadodara, gujarat (western railway).
Tender For provision of 01 x 30 kva genr with connected items as standby power requirements for sewage treatment plant under age (i) bhalra - supply, installing, commissioning and testing, water cooled, sound proof silent type, turbo charged, diesel engine driven generating set 30 kva (at 0.8 pf), 415v, 3 phase, 4 wire engine as per is: 10001/10002 and alterator as per is: 13364, complete with relay panel for automatic starting on mains failure, control panels having meters in an integral acoustic enclosure as per recommendation cpcb norms, comprising of the following:notes: quoted rates shall deemed to include the following also:-(i) supply of t and p and normal space ie., bi-hexagonal ring spanner set of 12 pieces - 01 set.(ii) fuel measuement gauge - 01 no, hand operated fuel lifting pump with steel pipe 40mm dia - 01 no, hydro meter - 01 no, set of fan belt, oil/ fuel filters initial filling of coolant (coolant-2liters).(iii) service maintenance manual along with cat part list and price list - 03 set each.(iv) make of engine and alternator will be got approved from age (i) bhalra before placing the order., (a) diesel engine. diesel engine developing suitable bhp, 1500 rpm inclusive of the following standard accessories:(i) radiator/ heat exchanger cooling system. (xiv) battery charging generator.(ii) spider coupling guard. (xv) industrial silencer.(iii) fly wheel. (xvi) lubricant oil cooler.(iv) fly wheel housing complete with starter gear ring and coupling. (xvii) flexible pipe for silencer. (v) fuel pipes. (xviii) battery volt meter.(vi) air cleaner. (xix) water temperature gauge, lub oil pressure (vii) fuel and lubricant oil filter. gauge.(viii) by pass filter. (xx) speedo meter and engine running hours meter.(ix) coolant inhibitor. (xxi) display for fault.(x) fuel pump. (xxii) turbo charger.(xi) water pump. (xii) lubricant oil pump.(xiii) self/electric starter.(b) alternator : synchronous alternator 3 phase 4 wire, 50 cycles 1500 rpm, self excited, self regulated, brushless type, 0.8 pf, 415v, ac supply, 30 kva capacity, copper wound, complete including necessary tools, mounted on strong rigid steel fabricated base frame and directly coupled through flexible coupling with diesel engine, complete all as specified and directed., (c) amf/ control panel : amf panel factory made of suitable capacity as per original equipment manufacturer make and specification or as approved by oem for dg set of capacity 30 kva of suitable size, indoor cubical type, front and back openable fabricated out of mild steel sheet 1.6mm thick grounted in floor with adequate pcc foundation and minimum consisting of following :(i) contactor of suitable size for 30 kva dg set.(ii) copper bus bar of suitable current rating and sensitivity relay set unit with auxiliary cts.(iii) electronic latch circuit with tripping indication.(iv) re-set facilities.(v) 3 phase mvr relay unit with single phase protection complete with 2 no nc auxiliary contacts.(vi) 3 phase avr relay unit complete.(vii) self sequential starting relay unit 12 volts dc complete with alarm and power contactor. (viii) electronic timer 220 volts for main contactor with 1 no nc auxiliary contactor.(ix) electronic timer 220 volts for fuel cut off operation with 1 no auxiliary contactor.(x) battery charging 2x12 volts 10 amp complete with digital voltmeter and amps meter, including trickle and boost charging, make : su-kam, amco, exide or any other make as recommended by the manufacturer.(xi) volt meter 0-500 volts panel mounting of size 96mm square with selector switch digital type.(xii) amps meter 0-100 amps with 3 nos cts, 400/5 and selector switch 96 mm square digital type.(xiii) frequency meter (45-55) hz, 415 volt, 96mm square digital type.(xiv) the amf panel should have manual by pass arrangement too in case of failure of amf panel., (d) fuel tank of capacity as per manufacturer recommendations.(e) base frame made out of suitable channel duly reinforced and provided with adequate numbers of anti