Get complete information related to latest Monitoring Equipment Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Monitoring Equipment Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Monitoring Equipment Tenders.
Tender For corrigendum : supply of switching impulse board , racks power supply board inco spares , servovalve amplifier , diving servocontrol , cpu board set , cpu board set front and rear servo , i o bus interface board , logic 2 3 board , analog input board current , voltage analogic inputs , 4 x channel rs485 module , logic output module , vme io interface board , serial link mother board , module c633 a ssu , logic input module , current analogic , voltage analogic , ventilation fan rack 19 , cpu board set for normal monitoring , esd kit electrostatic sensitive device kit , interface test equipment including laptop software , current test adapter for echosounder , drs1 simulator tool cs 55 , tool set of adaptor seb5900 , 1 wk12 dummy load tool cs 118 , dummy load for sonar beacon
Tender For purchase of ece practical equipments - equipments for ece practices:, single output regulated dc variable power supply input voltage: 230v / 50hz ac. output voltage: (0 30) v dc. output current: (0 2) a dc. protection circuit: over voltage, over current, and short-circuit protection. high efficiency: greater than 85%. low ripple and noise: less than 50 mv. digital display., dual output regulated dc variable power supply input voltage: 230v/50 hz ac. output voltage: (0 30) v dc. output current: (0 2) a dc. protection circuit: over voltage, over current, and short-circuit protection. high efficiency: greater than 85%. low ripple and noise: less than 50 mv. digital display, function generator frequency range: 0.1 hz to 5 mhz. display: 4 to 6 digit led display. output waveforms: sine, triangle, square, pulse, ramp. amplitude: 0 20 vpp. rise time: 100 ns. distortion: 1% within specified frequency range. power supply: 230 v ac 10%, 50 60 hz. output amplifier protection: short-circuit and 15 v overload protection. dc offset: 0 to 10 v adjustable. attenuation: 0 to 60 db., dso (digital storage oscilloscope) bandwidth: 50 100 mhz. sampling rate: 1 gs/s. channels: 2 (minimum). power supply: 100 240 v ac, 50 60 hz. automatic measurements: vpp, vavg, vrms, frequency, period, vmax, vmin, rise time, fall time, +width, width, +duty, duty, etc. horizontal scale: 5 ns/div 50 s/div or equivalent. vertical resolution: 8 bits (2 channelssimultaneously). vertical sensitivity: 1 mv/div 10 v/div (at input). waveform math: +, , , , invert, fft, etc. waveform storage: 16 waveforms or equivalent. communication interface: usb host and usb interface. display: 7-inch color display or equivalent. input impedance: 1 m 2% || 20 pf. accessories: 2 passive probes (1x/10x)., digital ic trainer kit with breadboard +5 v dc, 1 a regulated power supply. 12 v dc/ 15 v dc, 200 ma regulated power supply. solderless breadboardwith minimum 840 tie-points,power distribution buses. zif (zero insertion force) ic socketsto accommodate 8 or 16 pinics. logic input and output leds for output monitoring. 16 buffered led outputs. 16 debounced switch inputs. variable clock generator: 0.5 hz to 50 hz. single pulse output: 100 ms (buffered, positive and negative outputs). one seven-segment display with 4 bcd inputs. built-in logic switches. manual clock: debounced push-button (one pulse per press)., fpga trainer kit must use industry-standard mid-range fpga device usb-jtag programmable, compatible with vivado ise (webpack). power supply: 5 v dc through usb or external adapter. on-board peripherals: leds, switches, push buttons, 7-segment display,clock source, gpio / pmod expansion ports, uart, vga / hdmi, usbuart bridge, usb cable. user manual.
Tender For corrigendum : expression of interest for the selection of system integrator for supply installation commissioning maintenance of monitoringequipment at police stations/iccc and emergency call point ecp at public places/emergency call box ecb duress alarm or help point
Tender For corrigendum : “supply, installation, commissioning & maintenance of monitoringequipment at police stations and emergency call point (ecp) at public places in gurugram”
Tender For supply of materials for flood and disaster management - flood protection works, supply and placement of sandbags for flood control, construction of temporary earthen embankment, installation of flood barriers/water-filled barriers, emergency response equipment, inflatable rescue boat with outboard motor, life jackets and personal flotation devices, lifebuoys, rescue ropes, portable water pumps for dewatering, emergency lighting towers, portable generators, public address and warning systems, relief and shelter items, temporary shelter tents, tarpaulin sheets, folding cots and bedding kits, hygiene and sanitation kits, monitoring and early warning systems, automatic water level monitoring station, rainfall monitoringequipment, flood warning siren system, control room equipment and software
Tender For supply, installation and testing of electronic equipments - supply -ece lab equipments, single output regulated dcvariable power supply- input voltage: 230v / 50hz ac. output voltage: (0 30)v dc. output current: (0 2)a dc. protection circuit: over voltage, over current, and short-circuit protection. high efficiency: greater than 85%. low ripple and noise: less than 50 mv. digital display., dual output regulated dc variable power supply- input voltage: 230v/50 hz ac. output voltage: (0 30)v dc. output current: (0 2)a dc. protection circuit: over voltage, over current, and short-circuit protection. high efficiency: greater than 85%. low ripple and noise: less than 50 mv. digital display., function generator - frequency range: 0.1 hz to 5 mhz. display: 4 to 6 digit led display. output waveforms: sine, triangle, square, pulse, ramp. amplitude: 0 20 vpp. rise time: 100 ns. distortion: 1% within specified frequency range. power supply: 230 v ac 10%, 50 60 hz. output amplifier protection: short-circuit and 15 v, digital ic trainer kit with breadboard - +5 v dc, 1 a regulated power supply. 12 v dc / 15 v dc, 200 ma regulated power supply. solderless breadboard with minimum 840 tie- points,power distribution buses. zif (zero insertion force) ic sockets to accommodate 8 or 16 pin ics. logic input and output leds for output monitoring. 16 buffered led outputs. 16 debounced switch inputs. variable clock generator: 0.5 hz to 50 hz. single pulse output: 100 ms (buffered, positive and negative outputs). one seven-segment display with 4 bcd inputs. built-in logic switches. manual clock: debounced push-button (one pulseper press)., dc voltmeter(digital) - dc digital voltmeter - 3 digit led/lcd display, measurement range: 0 20 v dc,accuracy: class 0.5( 0.5 % full-scale), dc ammeter - dc ammeter digital - 3 digit led/lcd display, measurement range: 0 5 a dc,accuracy: class 0.5 ( 0.5 % full-scale), lvdttrainer kit - ac mains power supply: 230 v 10%, 50 hz. fixed regulated dc power supply: +5 v, 12 v / 500 ma. transducer: lvdt. lvdt displacement: 20 mm (40 mm total). displacement scale: linear 20 mm. displacement display: red color 3 digit led display. excitation frequency: 4 khz. excitation voltage: ac variable excitation voltage up to 5 v., strain gauge trainer kit - ac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. instrumentation amplifiers with 3 digit display for strain / output voltage. table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords and user manual., ask modulation and demodulation kit - message signal1:8-bit variable data,amplitude 5v. message signal 2:debounced data, amplitude low (0) and high (5 v). message signal 3:fixed data 25 khz, 12.5 khz, 6.25 khz, 3.12 khz,amplitude 5 v. carrier signal: sine wave, frequency 200 khz, amplitude 5 v. supply voltage (board): +12 v, +5 v dc. input voltage: 230 v ac, 50 hz. interface connectors: 2 mm banana socket., fpga trainer kit - must use industry-standard mid-range fpga device usb-jtag programmable, compatible with vivado ise (webpack). power supply: 5 v dc through usb or external adapter. on-board peripherals: leds, switches, push buttons, 7-segment display,clock source, gpio / pmod expansion ports, uart, vga / hdmi, usb- uart bridge, usb cable. user manual., measurement scale: a vertical steel meter scale, usually with (1mm) graduations, for precise deflection measurement., accessories: includes a set of slotted weights (e.g., (6times 50g) or similar sets) for incremental loading.