Web Analytics Made Easy - StatCounter

Mono Block Pump Repair Tenders

Get complete information related to latest Mono Block Pump Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Mono Block Pump Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Mono Block Pump Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :42402868 Due date: 11 Nov, 202511 Nov, 2025 NA
Tender For custom bid for services comprehensive annual maintenance contract of imu equipment-annual maintenance contract of pky tester oxygen booster pumps- 1. the pky tester is supplied by telektron (india) and there are three in no pky available in imu. 2. the purpose of pky tester instrument is to check function of breathing valves, all fitments and safety arrangements provided on breathing apparatus ida-59m hydrosuits. 3. it consists of following parts: 4. (a) (b) pressure guages p1(range 0 to 30 bar), p2 (range 0 to 10 bar) and p3 (range 0 to 2000 mm of wc) & flowmetres f1(range 0 to 6 lpm) f2 (range 0 to 200 lpm) f3(range 0 to 200 lpm) to monitor vacuum flow and f4 (range 0 to 1000 cc per min) (c) stop valves 05 in nos needle valves (s1, s2,s3, s4, s5) (d) pressure reducing valve (prv) : make: shavo's regulator unit model : 11-4snr type: spring loaded throttle valve range: 0.7 to 7.00 kgf/cm air drying unit : (a) (b) moisture and humidity filter: make : shavo's vayu standard series model: sb60 operating pressure range: 17.5 kgf/cm oil filter : make : shavo's vayu coalescing type oil filter model: sf60c operating pressure range: 17.5 kgf/cm .

CTN :41822295 Due date: 31 Oct, 202531 Oct, 2025 NA
Tender For corrigendum : supply of grid couplings for recirculation pumps of tc9 andm tc11 vacuum pumps for unit-1and2 of tm division

CTN :42412465 Due date: 30 Oct, 202530 Oct, 2025 4.23 Lacs
Tender For urgent repairs of defective and perished pumps and vacuum pumps, and replace the impellers at various lis under electrical wing irrigation section kalady- general electrical work

CTN :42412881 Due date: 22 Oct, 202522 Oct, 2025 2.00 Lacs
Tender For procurement of toshniwal make spares for seal oil vacuum pumps at stpp, jaipur, mancherial, telangana.

Central Government / Public Sector

CTN :42067879 Due date: 25 Oct, 202525 Oct, 2025 NA
Tender For corrigendum : supply of vacuum pumps along with accessories such as vacuum filters and seal kit

CTN :42362919 Due date: 31 Oct, 202531 Oct, 2025 NA
Tender For mtps-ii (1x600mw) - es circle -tgm&ca division - attending to general cleaning and daily maintenance work including minor repairing work of hip casing, lp-a & lp-b casings, bearing lube oil system, control oil system and its external purifier, jack oil system, boiler feed pumps & booster pumps, steam driven boiler feed pumps, booster pumps, bfp a&b lube oil system, hp/lp bypass system and its external purifier, hp&lp condenser, condensate extraction pumps a, b & c, and air evacuation system including vacuum pumps a & b , condenser on line tube cleaning system, centrifuges for lube oil and centralized lube oil system and miscellaneous pumps for the period of 365 days from the date of taking over of the site.

CTN :42101076 Due date: 20 Oct, 202520 Oct, 2025 NA
Tender For replacement/recapitalization of damaged components of hsc 7.2 cusecs pumps and motor sets, 02 no vacuum pumps along with allied works at lis raya.

Central Government/Public Sector

CTN :42113289 Due date: 27 Oct, 202527 Oct, 2025 12.14 Crore
Tender For corrigendum : tender for supply of oil spill response equipment : : - pressure inflatable boom , weir skimmers , mini vacuum pumps , bio remediation , level abcd protection

State Government

CTN :41676459 Due date: 17 Oct, 202517 Oct, 2025 NA
Tender For corrigendum : empanelment of agencies for supply of different laboratory instruments for various water testing laboratories under jal jeevan mission, assam - ion meter with electrode and accessories for fluoride & nitratemeter: ph/ion/ mv-redox-orp/ temperature benchtop meter with electrode for testing both fluoride & nitrate separately in water samples. technical specification: ph range: -2.000 to 20.000 resolution 0.1, 0.01, 0.001 accuracy 0.002 ph + 1 lsd calibration points up to 5 buffer sets: usa/ nist/ din/ custom orp range 2000.0 mv rel. mv range 2000.0 mv accuracy 0.2 mv resolution 0.1 mv ion concentration 0.001 to 19999 ppm resolution up to 3 digits relative accuracy 0.5 % full scale (monovalent) and 1 % full scale (divalent) calibration points up to 8 temperature range 0 to 100 c, 32 to 212 f resolution 0.1 accuracy 0.3 c/ 0.5 f compensation: auromatic temperature correction other requirement: auto buffer recognition, memory 500 with time and date stamp rs 232 alarm for calibration due & out of range alurm auto logging function., fluoride electrode of ion metersame make that of the ion meter, nitrate electrode of ion metersame make that of the ion meter, manifold filtration assembly (to be used for micobiological test)* sturdy and easy to clean ss filtration assembly with funnel, manifold unit, air vent filter and vaccum pump ready to be used for mictobiological testing * specification: # funnel with inbuilt clamp: made of ss 316, capacity: 300 ml, ss filter support base, ss support screan: 47 mm, made of ss 316l; filtration area 9.6 cm2; silicon stopper: size 8, with silicon lid and silicon o ring. # filtration manifold: 3 place manifold, made of ss 316, valves made of ptee, connection 12 mm; suitable for both pp and ss funnel with rubber stopper fittings. # vacuum pump: oil free, piston powered, suitable to be used with 3 possition manifold; max flow rate: 34 l/ min; vaccum stage: double. max vaccum: 100 mbar. the vaccum pump should also have a vacuum suction bottle to protect the pumps componennt by preventing liquid or solid material from entering the pump during filtration process., voltage stabilizer (3 phase)# capacity- 3 kva # input voltage range: 295 v - 465 v normal range # output voltage range 380 v / 400 v / 415 v # output regulation: 1 %; # output settability: 380 v - 420 v; # frequency: 47 hz - 53 hz; correction rate: 70 v/ sec; # aircooled servo stabilizer, three phase., heating mantle (single station) should have safety cut off with precise heating for boiling, evaporation, distillation or extraction process technial specification: flask capacity 250 ml, working temp range: ambiant + 5 to 350 degree celcius. accuracy: 1.0 degree celcius, display: led display with temperature, time; construction material: ms; power consumption : 150 w, semi automatic digestor for cod analysis with all assssories material of construction epoxy painted with chemical resistant coating; temperature range ambient to 450 deg c # stability of temperature 0.5 deg c # temperature calibration - automatic; selectable ramp: upto 4 per program; digestion time range: 1 to 999 minutes; time selection: 1 minutes steps; countdown: digital readout; heating places - 6 possition; size of tubes: 250 ml test tubes (42 mm); power 1000 w; number of programmable methods 20 numbers. # the thermal digestion unit should have high thermal homogeneity # the setup should have small footprint., digital thermometer with probe# mini lcd thermometer # type: digital, # sensor cable length: 1 meter water proof probe # batteries: 2 x batteries should be included, # temperature range: - 50 - 110 oc, # temperature measurement accuracy: 1 0c, micropippete stand#self-standing holder accommodates most major brands of pipettes. #material: pmma, # capacity: 5 pipptes/stand, conical flask draining rack#material: acrylonitrile-butadiene-styrene/polycarbonate, # no. of pegs: 20

State Government

CTN :41537812 Due date: 27 Oct, 202527 Oct, 2025 6.66 Crore
Tender For corrigendum : e.p.c contract for design, engineering, manufacturing, testing, supply, installation and commissioning of liquid ring vacuum pumps in 200 mw unit no.4 at gsecl ukai tps.(et-6005 tmd-ii)
 Loading, Please wait...