Get complete information related to latest Monochromator Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Monochromator Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Monochromator Tenders.
Tender For supply of spares of gas chromatography gc 2979 (analytical) - potentiometer for gc fid injection, gc gas tight syringe (20ml), gas linear for injector, graphite's for capillary column (1 pkt-5 nos.)
Tender For supply of machinery and equipment - uv-vis spectrophotometer spectrophotometer should be of true double beam optics system. sample compartment should have dedicated one reference cell holder and one sample cell holder. system should be czerny-turner monochromator with lo-ray-ligh grade blazed holographic grating or equivalent. system should have a light source of 20-w halogen lamp and deuterium lamp. automatic switch over of light source to be possible and auto position adjustment. system should have a fixed spectral bandwidth of 1nm. system should have facility to use as stand-alone keyboard-display and with pc-controlled software. wavelength range should be from 190 nm to 1100 nm and wavelength accuracy should be 0.1 nm at d2 656.1 nm & 0.3 nm for entire range. stray light: less than 0.02% at 220 nm (nai)less than 0.02% at 340 nm (nano2) less than 0.5% at 198 nm (kcl) photometric range:absorbance: -4 to 4 abs transmittance: 0% to 400% system should have photometric accuracy : 0.002 abs at 0.5 abs 0.004 abs at 1.0 abs 0.006 abs at 2.0 abs(measured using nist930d/nist1930 or equivalent) system should have a baseline flatness: less than 0.0006 abs (1,100 to 190 nm, one hour after light source turned on) system should have a noise level: less than 0.00005 abs (700 nm). detector should be silicon photodiode only. system should have a usb drive port to connect the printers or external drives. system should compulsorily have bio-method mode of measurement for determining dna and protein concentrations. quantitates dna or protein using the absorbance at 260/230nm. system should be capable of identification of organic compounds, chemical reaction tracking and enzyme reaction measurement. pc with relevant hardware including monitor keyboard, mouse., fuming hoods the proposed floor-mounted aerodynamic fume hood (1800 1000 2350 mm) is designed for safe handling of hazardous fumes, ensuring high performance, durability, and compliance with international standards. the system should be a robust, corrosion-resistant, and safety-compliant solution with efficient airflow management, user-friendly maintenance features, and adherence to international laboratory safety standards ideal for advanced research and chemical handling applications.1) design & compliance aerodynamic structure with automatic bypass airflow system. conforms to ashrae 110:2016 / en 14175 standards, including tracer gas containment test. certified ashrae compliance required 2) construction & materials made of powder-coated galvanized iron (gi, 120 gsm, is 277 compliant) sheet thickness: 1 mm (1.2 mm for structural supports) heavy-duty base frame: 60 40 2 mm phenolic resin (6 mm) inner liner: chemical-resistant, smooth, easy to clean ss 304 worktop with 15 mm raised edges for spill containment ss 304 aerodynamic airfoil with anti- corrosive coating 3) dimensions & workspace usable workspace: 1500 mm (w) 850 mm (d) 1180 mm (h) clear viewing height: 1100 mm modular base cabinets with maintenance access 4) coating & finish 8-stage chemical pre-treatment epoxy polyester / polyurethane coating (70 80 microns) corrosion resistance validated by 1000-hour salt spray test 5) functional features vertical sliding toughened glass sash (4 5 mm), counterbalanced openable front top panel for easy maintenance aerodynamic baffle system for efficient fume removal (light to heavy fumes) flow control damper for airflow regulation 6) utilities & safety integrated gas, water, and electrical fittings in corner posts remotely operated, color-coded service valves safety partition between utilities no cable entry below sash (enhanced safety design) electrical fittings: norysis /legrand (230v, 5/16a, 50 hz) 7) accessories pp cup sink with water tap and drainage led lighting with protective enclosure adjustable leveling screws ( 10 mm) storage base cabinets with shelves and self-closing shutters 8) centrifugal blower specifications remote, silent ms + frp blower with chemical-r
Tender For purchase of one number xe annual rate contract lamp (300 w) with monochromator and am 1.5 optical components or corresponding lasers to the smart materials lab,
Tender For purchase of one number xe annual rate contract lamp (300 w) with monochromator and am 1.5 optical components or corresponding lasers to the smart materials lab, department of nanoscience and technology, university of calicut
Tender For corrigendum : providing of customized annual maintenance contract/cmc for pre-owned products - procurement of gas chromatography mass spectrometry (gc - ms) spares of gc, usm, fc on oem basis for elster make metering skids
Tender For corrigendum : supply of pcb chopper : : - pcb chopper looker assembly savantaa , grating holographic including mounting stud for aas , spherical mirror for monochromator , tubing, nylon 1 by 4 inch o. d. red , tubing, nylon 1 by 4 inch o. d. blue , optics cover assembly - savantaa , spray chamber o-ring kit viton for savantaa , nebulizer titanium complete with push on low memory bung - savantaa
Tender For supply of gas chromatography spares d d - cic make gas chromatography model dhruva, temperature controller , cic make gas chromatography model dhruva, ssr 25amp dc to ac , cic make gas chromatography model dhruva, mol sieve 5a column , cic make gas chromatography model dhruva, heater coil , cic make gas chromatography model dhruva, tc-k sensor , cic make gas chromatography model dhruva, spares installation and commissioning charges , cic make gas chromatography model dhruva,tcd amplifier pcb