Get complete information related to latest Monolithic Joint Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Monolithic Joint Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Monolithic Joint Tenders.
Tender For corrigendum : supply and execution of various signalling equipments as per boq attached inspection rites consignee - fabrication and supply of point rodding (ground connection) set with insulation complete set for electric point machine 220 mm stroke clamp type for thick web switches as per rdso drg no rds0/s/3454 alt -a ver-1 or latest. (inspection agency:- rites), supply and fixing of gi bend pipe 50 mm dia., bclass, for cable entry into point machine with all accessories. note: th is item to be operated independently for those points where point machines are functional, but gi bend pipe is not provided. for all other new installation of point machines, item 06002 of the sor includes the provision of gi bend pipe. (inspection agency:- consignee), supply of point machine ground connection insulation complete set including for p bracket insulation for point machine irs type 220 mm.(inspection agency:- rites), supply of stretcher bar insulation complete set for point machine irs type 220 mm stroke clamp type.(inspection agency: - consignee)., supply of track lead junction boxes fiber glass as per drg.no. cwm - 00597 of f.r.p material to irs.s.23 specification along with fixtures i.e., on ms angle 50x50x5mm, 0.9 meters long two numbers of g.i. pipes of 25mm dia. along with nuts and bolts and 500mm long (this includes gromite bushes, 60mm pbt terminal). (inspection agency:- consignee), supply of aluminium ladders of height 5 feet for maintainer at relay room and ips room of model no: 8226 of youngman, plantex or similar. (inspection agency: - consignee)., supply of lps 3.00 mm thick rolled copper strip of reputed branded make. (inspection agency: - consignee), supply of insulation resistance tester. make fluke 1507 or similar. (inspection agency:- consignee), supply, fabrication and fixing of the calling on board/bslb board as per rdso drg. no. sa 2373 (adv)/stop/warning board as per drg. no. sa-2380 (adv), or as applicable, on concrete foundation and painting with retro reflective paint. all work to be carried out as per railway site engineer instructions.(inspection agency:- consignee), supply, fabrication and fixing of retro reflective signal number plates as per ncr drg. no. typ/14/0014 dtd 28.11.2014 issued vide ncr letter no. s&t/ ncr/drg/typ dated 28.11.2014, on signal post with contractors own material like clamp, u bolts, nuts etc.(inspection agency:- consignee), supply of digital cable fault locator for metallic s&t cables of reputed make as per tec spn no. gr/tie-05/03, july 2006 & tec 73060:2006 like khushicomms model venus 120 orsimilar branded make. consignee shall approve the supply only after successful demonstration at site(inspection agency:- rites), supply and testing of cable route tracer and marker locator model and make 3m dynatel model locator 2273m or reputed branded make.(inspection agency:- rites), supply, installation and commissioning of central gateway. note: single centre gateway shall cater maximum up to 32 data transmitter node (modbus).(as per annexure a) (inspection agency:- rites), supply, installation, testing and commissioning of data transmitter node in location box. modbus type note: maximum range 400 meter. (as per annexure b) (inspection agency: - rites), supply, installation , testing and commissioning of data transmiter modbus cum repeater for augmenting range of ourdoor data transmiter node (modbus), where distance of location box is more than 400 meter with respect to central gateway.(as per annexure c) (inspection agency:- consignee), apparatus case led indication status display unit cum allarm system for yard.single display system shall cater to maximum 45 no of location boxes.(as per annexure d)(inspection agency:- consignee), fabrication, supply and fixing of p, c, a, g, ibs etc. marker disk painted and lettered with enamelled paint of approved colours, on signals, conforming to rdso drg. no.sa - 23456, as per standard practice and technical specifications.(inspection a
Tender For supply of portable electromagnetic radiation tester , portable optic fiber meter with cleaver cum lan tester , handheld digital oscilloscope , digital insulation tester megger 1000v , digital multimeter , portable water depth sounder , portable anemometer , portable cordless drilling machine , fan blower , electrical tool kit box , heavy item lifter mover tool , electronic component kit , re-work station temp 100 to 450 c with air flow 100cu per min , pcb soldering magnifying glass with led lamp , storage organizer for electronic component , rechargeable emergency light , hot air gun , rechargeable torch light , bench vice with clamp
Tender For supply of ethernate cables c c---item 10 , item 20 , item 40 , item 50 , item 60 , item 70 ethernet cable,utp,cat-6 (1) conductor: bare copper massive wire awg 24/1 (0.51 mm dia), (2)insulation polyolefin dia 1.0 mm (3) pair twisting: each two cores twisted to pairs: whbu/bu, whor/or, whgn/gn,whbn/bn, (4) cable lay up:four pairs stranded in one layer over central profile, (5) jacket:frnc halogen free, flame-retardant, grey ral 7035,6.5 0.3 mm dia,jacket with printing at regular intervals, (6) rated voltage 250 v,(7) loop conductor resistance at 20 c 190 /km, (8)insulation resistance at 20 c 5000 m , (9) mutual capacitance at 1khz is 50 nf/km, (10) impedance at 1mhz to 100mhz is 100 15 , (11)attenuation at 1 mhz is 2.1 db/100m, (12) maximum bending radius for fixed installation is 10 x d (outer diameter), (13) temperature range for fixed installation is up to +70 c, (14) fire performance: the cable shall be flame retardant type confirming to iec 60332-3 cat. c or ul type cm., 4 core compensating for pt- pt.rh10% thermocouple, conductor:multistranded insulation:non-flamable,heat and moisture resistant,positive core insulation of double sintered teflon having 0.05 mm thickness, then double fibre glass impregnated with silicon varnish having 50 micron thickness, then special flexible heat resistant silicon rubber having thickness of 0.80 mm to withstand heat moisture, negative core insulation of double sintered teflon having 0.50 mm thickness, then double fibre glass impregnated with silicon and moisture, overall asbestos braiding with polished yarn having ) /bid number : gem/2025/b/6991125 * /dated: 11-12-2025 & & / bid document 1 / 19
Tender For tender for supply of supply and installation commissiong d d -supply installation testing and commissioning of 2tr 24000 btu per hour minimum bee 3 star rated confirming to is 1392 part 2 2018 inverter type cassette split ceiling mount air conditioner having wireless remote controller led display for indoor unit motorized vertical horizontal swing controls air filters uto restart with memory features inbuilt drain pump rotary scroll hermetically sealed compressor and initial charge of eco friendly refrigerant condensor and evaporator coils of copper material suitable for operation on 230v 10 single phase 50hz ac power supply the indoor unit shall be suspended from the ceiling using threaded rods including clamps bolts nuts etc and the outdoor unit shall be mounted on floor complete as required , supply and laying of soft drawn copper refrigerant pipe of suitable size for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation including necessary brazing jointing etc as required for cassette split air conditioner as required for item no 1 , supply laying of 4c x 25 sqmm frls pvc insulated 1 1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 25 mm dia minimum thickness of 1 2mm pvc drain pipe along with accessories and necessary clamps with an u trap at the end as required , supply and fixing of 75mm dia minimum 18mm thickness pvc covering pipe using necessary bend colloc clamps threded rod supports accessories etc for laying copper refrigernt line electrical cable and drain line as required. , supply and installation of floor mounted powder coated ms 25 x 25x5mm l angle frame including clamps bolts nuts vibrating dampers as required , drilling of hole using core cutting machine of size up to 100 mm dia in concrete stone wall ceiling for laying refrigerant lines etc and finishing the same with cement mortar after laying , dismantling shifting of old 2tr cassette split air conditioner having indoor and outdoor units associated refrigerant pipes electrical wires and drain pipes including pump down of refrigerant. , making of necessary alteration of existing gypsum false ceiling for installation of cassette air conditioner indoor units including necessary aluminium channel support gypsum board necessary accessories including painting to match for the existing false ceiling , supply installation testing and commissioning of 2tr 24000 btu per hour and iseer value five star rated and compliance with is 1391 part 2 2018 wall mounted inverter type hi wall split cooling inverter air conditioner having wireless remote controller with led display hermetically sealed scroll rotary compressor and eco friendly refrigerant initial charge of refrigerant condensor and evaporator coils of copper material air filter with auto swing auto restart features suitable for operation on 230v single phase 50hz ac power supply the indoor unit shall be fixed rigidly on wall using necessary frame the outdoor unit shall be mounted on floor laying and interconnection of standard length copper refrigerant piping as supplied by the oem between indoor and outdoor units complete in all respects as required necessary drilling of hole and finishing the same to match for the surrounding as required. , supply and laying of beyond the standard length supplied by the oem copper refrigerant pipe of size suitable for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation for hi wall split air conditioner as required for item no 1 , supply laying of 4c x 25 sqmm frls pvc insulated 1 1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 75mm dia minim
Tender For supply of re-useable thermal insulation pads made with high temperature binder-less fiber mat and , 2. supply of adhesive tape for installation of re-useable thermal insulation pads (item no: -1) made