Get complete information related to latest Moose Conductor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Moose Conductor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Moose Conductor Tenders.
Tender For procurement of tools and plants for stringing in live hot line - 18mm plateena rope with break indicator -500 mtrs , 18mm plateena rope with break indicator -1000 mtrs , hanging rollers - double sheave- for conductor , leight weight single sheave aerial rollers for conductor -acsr moose or zebra or bersimis , two sheeve pulley block 2 nos per set suitable for 20 mm dia poly propylene rope having 5 t capacity , single sheeve pulley -open type- suitable for poly propylene rope-5 tcapacity for 24 mm dia rope , single sheeve pulley -close type- suitable for poly propylene rope5 t capacity for 24 mm dia rope , d-shackles-6.5t capacity , bolted type flat -patta- clamp for 7 by 3.66mm earth wire , 4 sheeve pulley block 5 ton capacity -2 nos- 1set , 12 mm dia steel 300 meter wire rope , articulated swivel joint , equalizer pulley-10 t capacity , light weight automatic type come along clamps for acsr mooseconductor , light weight automatic type come along clamps for acsr zebra conductor , light weight automatic type come along clamps for acsr bersimis for 765kv , steel wire rope sling for 12 mm x 1 meter both end spliced , steel wire rope sling for 18 mm x 1 meter both end spliced , steel wire rope sling for 18 mm x 2 meter both end spliced , steel wire rope sling for 18 mm x 2.5 meter both end spliced , steel wire rope sling for 18 mm x 5 meter both end spliced , 12 mm dia-poly propylene rope bundle of 220 meters each , 18 mm dia-poly propylene rope bundle of 220 meters each , 20 mm dia-poly propylene rope bundle of 220 meters each
Tender For survey for conversion of 400kv rtps-btps s/c line twin moose line by dc line with quad mooseconductor in 400kv tlm toranagallu division for a distance of 152kms.
Tender For work of enhancement of current carrying capacity of 132kv hatia ii ckt i and ii double circuit transmission line by replacing acsr panther conductor to acsr mooseconductor of 132 33kv grid sub station hatia i.
Tender For repairing of damaged y ph.(top conductor-twin-moose) conductor by dismantling/stringing with repair sleeve/joint sleeve on 400 kv charal-kosamba line between 146(s) to 147(s) under 220 kv limbdi jurisdiction of am div. limbdi of tr circle surendranagar.
Tender For corrigendum : rate contract for supply of electrical spares n minor store/hardware items, as given in the detailed boq, from govt approved reputed experienced competent n financially sound electrical contractors/firms/suppliers/joint ventures/executors/oems - part: (a) 132kv transmission lines (material ), al. alloy as per is: 617 of 1975 pg clamps 3 bolt type conforming to is: 5561-1970 (amended upto date) for acsr zebra conductor (make: rul, zi, honeywell, burma, pee, equivalent etc/ as per departmental sample provided)., p g clamp for acsr panther conductor as per relevant is/iec amended upto date and of reputed/standard make, p g clamp for acsr mooseconductor as per relevant is/iec amended upto date and of reputed/standard make, bi-mettalic ct clamp (universal take off) for panther conductor with ct terminals suitable for 132kv/33kv cts as per relevant is/iec amended upto date and of reputed/standard make, bi-mettalic isolator pad clamp (universal take off) of panther conductor with pad terminals suitable for 132kv /33kv isolators as per relevant is/iec amended upto date and of reputed/standard make, bi-mettalic isolator pad clamp (universal take off) of zebra conductor with pad terminals suitable for 132kv /33kv isolators as per relevant is/iec amended upto date and of reputed/standard make, bi-mettalic breaker pad clamp (universal take off) of zebra conductor with pad terminals suitable for 132kv /33kv breakers of sf 6 type-abb,cgl, siemens, bhel/vcb type- s&s, gec alsthom, bhel, abb, siemens, megawin etc as per relevant is/iec amended upto date and of reputed/standard make, bi-mettalic ct pad clamp (universal take off) for twin acsr zebra conductor with conductor spacing 300mm and ct terminal spacing of 140mm having bolts hot dip galvanized nuts and washers electro galvanized and current carrying capacity equivalent to ampacity of twin zebra conductor with pad terminals suitable for 132kv /33kv ct as per relevant is/iec amended upto date and of reputed/standard make, bi-mettalic twin isolator pad clamp (universal take off) conforming to is: 5561-1970 (ammended upto date) for twin acsr zebra conductor with conductor spacing 300mm and isolator pad clamp terminal spacing of 140mm having bolts hot dip galvanized nuts and washers electro galvanized and current carrying capacity equivalent to ampacity of twin zebra conductor with pad terminals suitable for 132kv /33kv isolator as per relevant is/iec amended upto date and of reputed/standard make, bimetallic ct pad clamp (universal take off) conforming to is: 5561-1970 (ammended upto date) for twin panther conductor with conductor spacing 300mm and ct terminal spacing of 140mm having bolts hot dip galvanized nuts and washers electro galvanized and current carrying capacity equivalent to ampacity of twin panther conductor as per relevant is/iec amended upto date and of reputed/standard make, bimetallic breaker pad clamp (universal take off) conforming to is: 5561-1970 (ammended upto date) for twin panther conductor with conductor spacing 300mm and terminal spacing of 140mm having bolts hot dip galvanized nuts and washers electro galvanized and current carrying capacity equivalent to ampacity of twin panther conductor as per relevant is/iec amended upto date and of reputed/standard make, bi-mettalic isolator pad clamp (univercial take off) conforming to is: 5561-1970 (ammended upto date) for twin panther conductor with conductor spacing 300mm and isolator terminal spacing of 140mm having bolts hot dip galvanized nuts and washers electro galvanized and current carrying capacity equivalent to ampacity of twin panther conductor with pad terminals suitable for 132kv /33kv isolator of reputed/standard make, bi-mettalic isolator pad clamp (univercial take off) conforming to is: 5561-1970 (ammended upto date) for single panther conductor of reputed/standard make, t-clamps 3 bolt type conforming to is: 5561-1970 (amended upto date) for acsr -panther-acsr panther conductor of repute
Tender For work of acsr twin mooseconductor replacement of 220kv bus-1, including jumpering work approve under r&m plan at 220kv jambuva ss under tr circle jambuva.
Tender For purchase of 22kv to 400kv bus post insulators with clamp connector & w/o structure for year 2025-26 as per specification on firm price basis. - 400kv 8 kn bpi w/o strucure - with clamp connector (fix & sliding to receive 4" ips al tube) w/o structure suitable for twin moose, 400kv 8 kn bpi w/o strucure - with clamp connector (expansion type to receive 4" ips al tube) w/o structure suitable for twin moose, 220kv bpi w/o structure with clamp connectors suitable for twin zebra as per technical specifications (350mm spacing), 220kv bpi, 8kn w/o structure with clamp connectors suitable for twin moose as per technical specifications (350mm spacing), 132kv bpi, 6kn w/o structure with clamp connectors suitable for twin zebra conductor as per technical specifications, 132kv bpi, 6kn w/o structure with clamp connectors suitable for single mooseconductor as per technical specifications, 66kv bpi, w/o structure with clamp connector suitable for twin zebra (350mm spacing) as per technical specifications, 66kv bpi, w/o structure with clamp connector suitable for acsr panther conductor as per technical specifications, 66kv bpi w/o structure with single al 59 clamp connector as per technical specifications, 22kv bpi w/o structure with clamp connector suitable for acsr panther conductor as per technical specifications
Tender For conducting modern line survey for construction of 220kv dc line from ongoing 400/220 kv kustagi s/s at kustagi taluka, in koppala district to proposed 220/110 /11 kv sub-station at hungund using twin aaac mooseconductor in hungund taluk, bagalkot district for a distance of 34 kms.
Tender For procurement of hardware fitting and work of replacement of 33 kv main bus of single mooseconductor to double mooseconductor at 132 kv s/s shahganj under etd-ii jaunpur.