Get complete information related to latest Motor Operated Valve Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Motor Operated Valve Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Motor Operated Valve Tenders.
Tender For auction sale of rov pannel - lot 1,rov pannel - lot 2,oring leak detector of siraga make,1 x 24 station electronic carousal,valve and bulk leak detector,electronic check scale,drier of elgi make- 350 cfm
Tender For corrigendum : provn of icu, ot, hdu and allied ancillaries in mh ranikhet. - phase-i schedule a part-i (building work), construction of block of tech building for hospital icu, ot, hdu and allied ancillaries alongwith rcc covered ramp ( g+1) (rcc framed structure) , with permanent specification including plinth protection all as shown on drawings and as specified., construction of block of pump house (rcc framed structure) , with permanent specification including plinth protection all as shown on drawings and as specified., construction of under ground static water tank of capacity 100 kl, complete all as shown on drawings and as specified., schedule a part ii-a (internal water supply) for details refer sch a in pdf folder, schedule a part ii-b (internal water supply), s&f health faucet (abs body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 m long flexible tube and abs wall hook including making connections and fixed in position complete all specified and directed., s&f brass cp mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all specified and directed., s&f brass chromium plated angle valve, fancy type screwed for iron pipe suitable for 15 mm bore pipes complete all specified and directed., s&f brass chromium plated shower rose with 150 mm long cp shower arm 125 mm size revolving type suitable for 15 mm bore pipes, complete all specified and directed., schedule a part iii-a (internal electrification) for details refer sch a in pdf folder, schedule a part iii-b (internal electrification), m & l for point wiring using 1.50 sqmm size, pvc insulated, unsheathed 1100 volts grade, is-694 single core multi-stranded (frls-h) copper conductor cable in proper colour coding drawn into and including metallic rigid conduit medium grade (not less than 20 mm dia) with and including its all necessary fittings and accessories fixed concealed, sunk cast iron or 1.6 mm thick pressed modular steel terminal box for mounting fittings i.e, modular switch / sockets incl cover plate with frame including one continuous run of pvc insulated (green colour) 1.50 sqmm size stranded frls-h copper conductor cable as in earth wire and connecting all metal parts to common earth dolly incl cutting and chases pinning in for concealed conduit wiring and making good of disturbed surface complete all as specified and directed for the following: -, note: (i) also includes inverter wiring with one run of inverter wire 1.5 sqmm all alongwith circuit also included. (ii) all items used should be isi marked. (iii) cutting chases for concealed type point wiring including making good the same with plaster/putty is deemed to be included in quoted rate by the contractor. (iv) accessories modular metal boxes, cover plate inner & outer is also deemed to be included in quoted rate., (a) one light point point /bell buzzer/ ceiling fan/exhaust fan point controlled by one-one way switch. ( 9 points for lift schedule), (b) one three pin 5 amp socket on same board with other switches., (c) one three pin 5 amp socket on independent board, (d) all as per item no 5.01 above but for two way wiring, (e) all as per item no 5.01 above but point wiring with cable 2.50 sq mm size, with earth continuity conductor of size 2.50 sq mm. ( 9 points for lift schedule), supply and fix high quility led t5 integrated batten tube light 20 watt with aluminium extrusion with frosted pmma/pc diffuser, internaly pre wired of 1.5 sqmm twin twisted flexible cable incl connection with ceiling rose all as specified & directed., supply and fixing led batten light fitting 20w, 220v,with microwave motion sensor based technology with aluminium housing & integrated electronic driver of make havells with cat part no lumilinesmart20wled865pcwh or equivalent make of bajaj/philips/crompton complete all as specified & directed., supply and fix led bulb 9 watt complete all as specified and directed., s & f mccb 4 pole 200 a,
Tender For supply of starting relay 4 pin,flywheel sensor,system protection valve overhauling,gear box top bush kit lathe work,release bearing,benjo union bolt,radiator repair,diesel pipe,alternator main wire 8mm,ignition switch,pump solonoid switch,fuel feed pump assy overhauling,window regulator assy,door lock with key,clutch cylinder kit,door catch,engine diagnostic through laptop,injector servicing and pressure testing,electronic injector replacement edc pump assembly overhauling,fitment of edc pump in the vehicle and resetting,electrician labour charges for repairing all broken wires and replacement of clips,mechanical labour charges for removal of gear box assembly stripping rectification,starting relay 4 pin,fuel feed pump overhauling,nrd valve,banjo union bolt,clutch cylinder kit,brake shoe liner with reveitting,electrician labour charges for repairing all broken wires and replacement of clips,mechanical labour charges for removal of other unserviceable items fitment of new spare,starting relay 4 pin,engine diagnostic thr
Tender For supply of details description of specification for 100 watt led flood light - led rating in warm)/system wattage/rated power, led luminaire conformity to 15:10322/part 5/section 5/2012 latest and 15: 16107, (part 2/sec 1):2012, photo biological safety of leds used shall be as per 15:16108/2012 (exempt grou, types of led luminave as per the 15: 161070part-2/sec-11/2012, types of led modules as per the 25: 16103(part 2)/2012, led rating/system wattage/rated power, luminaire system efficacy bumen/watt), ingress protection (ip rating) as per 1 10322 (part 1): 1982 latest, mounting brackets fincluded, warranty for free replacement (in year), input operating voltage range and frequency, automatic higher cut off voltage above 300 volt, rated voltage, ac power factor at hill load, driver efficiency lin sage), total harmonics distortion (in lage), the total circut power shall not be more than 110 percent of the valve declared, by the manufacturer, led chip efficacy, colour temperature (+500), working life for led (minimum 50,000 buming hours as per lm-80 report), coltur rendering index(cri), optic lenise materal (uv stabilued) (write na or without optic lense supply), heat sink should be die-cast aluminum along with sufficient heat sink fins to desipate heat effectively, capacitor shall be ratail for a temperature of 105 deg. ceblus or better, junction temperature, operating temperature range, operating humidity range, short circuit protection, overload protection, over voltage geutection, reverse polarity, high voltage test (1.5 kv for ane minute between napply terminats and body of the, unit), insulation resistance between earth and current carrying part, the luminaire shad be protected against surges and transients (internal), the luminaire shall be protected against surges and transients of >/1kv, (external, the luminaires casing/housing (single piece housing) shall be pressure de catted, aluminum alloy with higher thermal.conductivity, the lummaire body must be corrosion resistant epoxy powder couted, all fasteners must be of stainless steel, the entire housing (both led section and driver section) shall be dust and water proof having ip 66 protection as per 15:10322 (part 11:1987 latest, luminaries light transparency should be of toughened glass, toughened transparent glass cover thickness, toughened glass shall not get discolored shall not suffer degration due to heat and agning within warranty period, number of electronic control gest (power sanoles), driver components shall be industrial grade or above, pci shall be fre grade minimum 0.8 to 1.0 mm thick or mom, the luminaires works on single phase three wires system (phase, neutral and, earth, suitable connector shall be provided for led connection between driver output, and led, length of st marked three cors wire (shall be provided along with supply of, materiall, ught source, manufactures name and and brand on the aluminium die cast body, manufacturer's name, model number, serial number, date of manufactiare (month-year), and int number as identification mark inside each unit and the outside of each packaging box, the operation characteristics voltage and power be marked inside of each led, system must have emi/emc compliance as applicable (test reports shall be furnish on demand by buyer/consignee)
Tender For supply of x2-aws-90kva-6220145739214 bdl part no 1840220200027 indication lamp blue mtrl no 10580490 , z21-aws-tcc-3030720482295 bdl part no 1840204200054 timer belt mtrl no 10582741 , x2-aws- 15kva-2920720501609 bdl part no 1840247200023 coolant temp sensor mtrl no 10583707 , x2-aws- 30kva-6110999753766 bdl part no 1840245200029 electronic control module mtrl no 10580366 , w2- aws-iacsv-4820720505796 bdl part no 1840217200081 auto drain valve for 2nd stage mtrl no 10580037 , z24-aws-msmc-18113055070100 bdl part no 18113055070100 cgu antenna hoods 02 nos mtrl no 10628346 , z24-aws-msmc-18113055070200 bdl part no18113055070200 rpf tx antenna hoods 02 nos mtrl no 10628347