Get complete information related to latest Mpcb Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Mpcb Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Mpcb Tenders.
Tender For supply of mpcb (motor protection circuit breaker) of current rating: 1.6 amps, thermal releaserange: 1.1 to 1.6 amps, class-10, breaking capacity: 50 ka, 3 pole, voltage rating 415 v ac with 01 no + 01 nc auxiliary contact block as per rdso spec. no. rdso/pe/spec/ac/0184-2015 rev.1 to abb model no.:ms132-1.6b, schneider model no. gv2me06, l&t model no. st41894oooo, siemens model no. 3rv2011-1aa10 and eaton model no. pkzm0-1.6.
Tender For supply of motor protection circuit breaker (mpcb) 6 to 10 amps, 690v ac, 50 hz, 3-pole typegv2p14 with aux. contact block 2 no (normally open) as per clw spec. no. clw/es/3/0096 alt.l orlatest.
Tender For supply of set of motor protection circuit breaker (mpcb), auxiliary contact and miniature circuit breaker (mcb) suitable for use in m/s sidwal & m/s intec make roof mounted cab air conditioning system of three phase locomotives as per rdso spec. no. rdso/2007/el/spec/0055. one set consist of 11 items in 22 nos. as per annexure- a
Tender For operation and maintenance of e&m services, dg sets, sub station, fire fighting/fire alarm system, vrf system, cctv system at central forensic science laboratory at rajarhat, new town, kolkata during 2025-2026. (sh: providing and fixing of relay, ammeter of 11 kv ht breaker).
Tender For supply of as per boq d d - main lt panel indoor type with fp ai high safety mode technology , apfc capacitor panel 1250 kvar indoor type with aluminium tp , vacuum circuit breaker panel 11 kva 800 amp and vcb panel , transformer 3500 kva input voltage 11 kv output voltage 415 v , earthing arrangement copper plate earthing with 50 kg of chemical earthing transformer - 3500 kva technical specification- 1- capacity : 3500 kva, 2- input voltage : 11 kv, 3- output voltage : 415 v, 4- number of phase : 3 phase 5- applicable standard : standard, 6- number of winding : 02 nos, 7- installation type : outdoor, 8- cooling type : onan, 9- terminal arrangement : bare, bushing for hv side & 10- cable box for lv side., 11- vector group : dyn 11, 12- ambient temperature : 50 c, 13- temperature rise of oil : 40 c, 14- temperature rise of winding : 45 c, 15- impedance : 6.25% (subject to +/-10% tolerance), 16- transformer oil : "a grade" tested & certified as per is:335 standard., 17- no load losses : as per is standard, 18- full load losses : as per is standard, 19- copper : pure electrolytic grade, 20- tapping mode 01 nos - rotary type off circuit tap changer (octc) with locking arrangement & tap indication., 21- basic insulation leve for hv : 75 kv peak / 28 kv rms, 22- basic insulation level for lv : - / 3 kv rms, 23- tapping range +5% to -5% in steps of 2.5% by off circuit tap changer (octc)., (a) earthing arrangement (1) copper plate earthing 600x600x6 mm with 50 kg of chemical compound depth around 10 meter with testing pit. (2) gi plate earthing 600x600x6 mm with 50 kg of chemical compound depth around 4 meter with testing pit. (3) copper strips 50*6 (4) gi strips 50*6 make premium, (b) cables and accessories (1) 3 c x 240 sqmm al armoured ht cable (2) joint kit (3) 3.5 c x 400 sqmm al ) /bid number : gem/2025/b/6768705 * /dated: 17-10-2025 & & / bid document 1 / 19
Tender For corrigendum : supply of electrical testing and calibration c c - testing of transformer tan delta , testing of lt breaker_starter , testing of ht breakers , testing of relays , testing of over load relay thermal , partial dischrg test for trmr , testing of third harmonic la , test - insulating matrubbeberting matrub , testing insulation resistance half yearl , polarization index test , transformer oil testing , calibration of meter , calib- elec. measuringelect. measuring i , testing of vcb bottle oisd-137 , thermography testing of panel , oil filtration of transformer , electrical safety audit , sup 33.0kv rubber hand gloves , current transformer testing upto 500a , vlf testing of cable report submission , winding temperature pc414 , testing and calib- otianalog_digi , liasoning charges , drop ourt fuse of 11 kva replacement , lightining arrestor of 11 kva replacemen , gos switch service and painting , ht cable insulation test , ht breaker lbs service , multi function meter mfm ) /bid number : gem/2025/b/6774505 * /dated: 10-10-2025 & & / bid document 1 / 25
Tender For supply of mpcb for condenser fan unit, thermal release range (rated current) 1.6 a - 2.5 a, class 10, breaking cap 50 ka, 3 pole, rated voltage 415 v ac, with 1no + 1nc auxiliary contact, as per abb- ms116-2.5, schneider- gv2me07, l&tst41895oooo, eaton- pkzm01-1.6+nhi-e-11-pkz0, siemens- 3rv2011-1ca10+3rv2901-1e. accepted make: abb/siemens/legrand/eaton/l&t only. note: material should be supplied by oem(as mentioned in material's description) or their authorised dealers only with uploading the oem's authorisation certificate while bidding.