Web Analytics Made Easy - StatCounter

Ms Cable Tray Tenders

Get complete information related to latest Ms Cable Tray Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ms Cable Tray Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ms Cable Tray Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45382837 Due date: 04 Jul, 202604 Jul, 2026 NA
Tender For corrigendum : repair/maint of external electric supply system, distribution lt panels with connected items and allied services at other than basistha area under ge guwahati. - excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out / laying of under ground cable, pole or stay and getting out in soft soil strata complete all as specified and as directed., returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cms spread any type of soil complete all as specified and as directed., removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed., supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. (note : punned thickness shall be measured)., m&l for bricks common burnt clay, building brick, sub class b designation 75 old size bricks laid in trenches flat over sand cushioning for cable protection complete all as specified and as directed., m&l for supply and fixing / laying in replacement, connect, test and commissioning of lt under ground cable xlpe insulated, screened, pvc bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor, 1100 volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cable glands,lugs and suitable size of ms saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and as directed.note : manufacturers test certificate shall be submitted alongwith rar/fb to engr-in-charge., (a) 95 sqmm x 3.5 core, (b) 70 sqmm x 3.5 core, (c) 50 sqmm x 3.5 core, (d) 25 sqmm x 3.5 core, supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 630 amps, 50ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 400 amps, 36 ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 250amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 160amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 125 amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 100amps, 26ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 63amps, 16 ka breaking

Central Government/Public Sector

CTN :45711103 Due date: 18 Jul, 202618 Jul, 2026 45.00 Lacs
Tender For repair/replacement of capacitor bank, sign board, fencing cable duct cover, route indicator and miscellaneous work at various sub station/installation at af stn gwalior.

Central Government/Public Sector

CTN :45365822 Due date: 06 Jul, 202606 Jul, 2026 39.99 Lacs
Tender For corrigendum : repair to security lights panels dg sets fire alarm ups with covered items at af stn bikaner under ge (af) nal - excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5m depth, getting out the excavated earth, forming bottom surfaces to required gradient complete all as specified and directed by engineer-in-charge., removal of excavated material soils to a distance n exc 50 m and depositing where directed at a level not exceeding 1.5m above the startly point complete all as specified and directed., returning filling in, including spreading, levelling watering and well ramming in layers n exc 25 cm as in any type of soil complete all as specified and directed., material and labour for sand cushioning using dry and clean tibba sand in two layers, first layers of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable in trenches/ducts including consolidation of each layers complete all as specified and directed. note : punned thickness shall be measured for payment., material and labour for un-reinforced pre-cast concrete cable covers, class lv type-1, flat size 250mm x 150mm x 40mm thick complete all as specified and directed., taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 2 core, 6 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 2 core, 10 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 4 core, 16 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 3.5 core, 25 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 3.5 core, 35 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 3.5 core, 50 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 2 core 6 sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by engineer-in-charge , supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 2 core 10 sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by engineer-in-charge, supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 4 core 16 sqmmlaid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by engineer-in-charge, supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 3.5 core 25 sqmm laid in trenches

CTN :45438320 Due date: 06 Jul, 202606 Jul, 2026 45.00 Lacs
Tender For corrigendum : supply of providing and laying of painting works , patch works , waterproofing works , dismantling false ceiling , dismantling bison board , dismantling woden partistion , window closing , dismantling existing washbasin , cleaning , room 3 , providing toilets , toilet renovation works , roofing and false celing works , room 9 , floor patch works , dismantling of toilets , dismantling damaged windows , room 14 15 , dismantling existing doors , repairs to existing ventilator windows , dismantling existing wall and floor tiles , structural repair and opening modification works , dismantling brick structure and floor repair , dismantling and vegetation removal , dismantling existing broken and damaged glass panes , cpvc water supply line , site clearance and general demolition works , anti termite treatment , rodent and pest control treatment , overhead water tank cleaning repair and disinfection , storm water drain and surface drainage , signage and room identification , comprehensive checking of 1 nos 250 kva outdoor type substations including inspection , aluminium paint , servicing of existing 11 kv 400 amps 3 pole gang operated type air break ab switch , supplying and replacing damaged or worn out copper metal , supplying and replacing damaged or defective 11 kv post top insulators , supplying and replacing damaged or defective 11 kv pin type insulators , servicing of earth pits , supply installation testing and commissioning lbs , xlpe insulated aluminium conductor armoured ht cable , providing indoor or outdoor type heat shrinkable , supplying and laying of 3.5 core x 240 sq.mm 1.1 kv grade aluminium conductor xlpe insulated , supplying and making end termination for 3.5 core x 240 sq.mm 1.1 kv grade , joint for existing single run lt power cable of size 3.5 core x 240 sq.mm , comprehensive servicing and preventive maintenance of existing ht transformer , supply, fixing, installation, testing and commissioning of lightning arrester , providing and fixing cable identification tags , supply, installation, testing and commissioning sitc main mv panel , supply, installation, testing and commissioning sitc cubicle pdb panel , supply, installation, testing and commissioning sitc feeder pillar box , providing and installation of maintenance free earthing station , supplying and laying of 3.5 core x 120 sq.mm 1.1 kv grade aluminium conductor xlpe insulated , providing laying and fixing of overhead perforated or slotted ms cable tray , supply installation testing and commissioning 7 segment distribution board , providing fabricating supplying, installing testing and commissioning of electrical socket box

State Government

CTN :45685997 Due date: 10 Jul, 202610 Jul, 2026 4.65 Lacs
Tender For repair to the existing cable duct in the station yard and other allied works at 220kv r/s sedam.

Central Government And Public Sector

CTN :45332724 Due date: 29 Jun, 202629 Jun, 2026 5.37 Lacs
Tender For corrigendum : supply of supply of 3 tr non inverter ductable ac as per bsnl specifications , itc of 3 tr non inverter ductable ac as per bsnl specifications , supply and fixing copper piping of 0.75 inch with nitrite foam insulation as required , supply and fixing copper piping of 0.625 inch with nitrite foam insulation as required , supply and laying 4 core 4 sq mm pvc insulated copper cable as required. , supply and laying 4 core 2.5 sq mm pvc insulated copper cable as required. , supply and fixing 1 inch dia pvc pipe for water drainage as required , s fixing ms structure of suitable size as required , making covering of extra oper space of leakge as required , supply and fixing 8way double door 4 and 24 nos tpn mcb db , supply and fixing 5a to 32 a tpn c curve mcb in extg db as required , supply and fixing 60a four pole isolator in extg db as required , supply and fixing single ploe blanking plates , supply and fixing 8 swg gi wire for loop earthing as required , supply and fixing 150mm x 50mm x 1.5mm perforated ms cable tray

corporations/Associations/Others

CTN :45585969 Due date: 23 Jun, 202623 Jun, 2026 52.06 Lacs
Tender For supply, installation, testing and commissioning of lt underground cables with allied items for various buildings in dbranl university, rai, district sonipat. - hsr part[23.22.1.12]mccb ,distribution boards, mcb`s, rccb`s, change over etc. 1.12. supply and erection of modular case circuit breaker single pole/4 pole on existing wall/pedestal/panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the engineer-in-charge of the work. 4 pole mccb 300 to 400 amp , 50 ka [through rate], [23.22.1.13]mccb ,distribution boards, mcb`s, rccb`s, change over etc. 1.13. supply and erection of modular case circuit breaker single pole/4 pole on existing wall/pedestal/panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the engineer-in-charge of the work. 4 pole mccb 600 to 800 amp , 50 ka [through rate], [23.22.1.3]mccb ,distribution boards, mcb`s, rccb`s, change over etc. 1.3. supply and erection of modular case circuit breaker single pole/4 pole on existing wall/pedestal/panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the engineer-in-charge of the work. triple pole mccb 16 to 100 amp, 25 ka [through rate], [23.22.1.5]mccb ,distribution boards, mcb`s, rccb`s, change over etc. 1.5. supply and erection of modular case circuit breaker single pole/4 pole on existing wall/pedestal/panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the engineer-in-charge of the work. triple pole mccb 200 to 250 amp, 25 ka [through rate], [23.22.5.1]mccb ,distribution boards, mcb`s, rccb`s, change over etc. 5.1. supply and erection of miniature circuit breaker 240/415 v in the existing distribution board including making necessary connections:- 6 amp. to 32 amp single pole [through rate], [23.22.5.7]mccb ,distribution boards, mcb`s, rccb`s, change over etc. 5.7. supply and erection of miniature circuit breaker 240/415 v in the existing distribution board including making necessary connections:- 6 amp. to 32 amp mcbs four pole [through rate], [23.22.5.8]mccb ,distribution boards, mcb`s, rccb`s, change over etc. 5.8. supply and erection of miniature circuit breaker 240/415 v in the existing distribution board including making necessary connections:- 40 amp to 63 amp. mcbs four pole [through rate], [23.22.8.4]mccb ,distribution boards, mcb`s, rccb`s, change over etc. 8.4. sitc four pole on load manual change over switch in ss enclosure of following ratings 300 amp 415 volts [through rate], [23.22.8.5]mccb ,distribution boards, mcb`s, rccb`s, change over etc. 8.5. sitc four pole on load manual change over switch in ss enclosure of following ratings 400 amp 415 volts [through rate], [23.23.6.4]miscellaneous 6.4. supply and erection of ms cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of engineer-in charge of the work. ms perforated cable tray painted with powder coating 600 x 50 x 2 mm [through rate], [23.23.7.4]miscellaneous 7.4. supply and erection of cable tray cover made of 1.25 mm thick gi sheet as required including erection of the same on existing cable tray with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of engineer-in charge of the work. gi cable tray cover , suitable for cable tray of 600 x 50 x 2 mm [through rate], [23.24.1]ms stand, bus bar chamber and panels 1. supply and erection of m.s. angle iron frame duly welded for housing m.s. sheet & main switches etc. on it, fixed on wall by means of suitable size of rag bolts with cement concrete, duly painted with three coats of

Central Government/Public Sector

CTN :45303050 Due date: 26 Jun, 202626 Jun, 2026 NA
Tender For corrigendum : tender for supply of electrical fitting and fixures - upvc 4 way junction box 1 inch thickness is to 2 mm make legrand or anchor or abb or mk or schneider or siemens or l and t or l k or kolors or wipro or indoasian elvira , 185 sq mm straight aluminium lugs heavy duty lugs or any reputed brand , 300 sq mm straight aluminium lugs heavy duty lugs or any reputed brand , 70 sq mm tubular terminal copper lugs heavy duty lugs or any reputed brand , single phase preventor 415 vac make easun or ge or abb or schneider or siemens or cg , 300 mm ms cable tray 14 swg powder coated performated type of any reputed brand size 300mm x 50 mm standard size 2 point 5 mm or more make maa industries mumbai or profab of indiana or essar or protec or akg or pai fab or classic engineering solutions or fixotech engineering systems or innospacer engineer technologies , 100 x 100 x 65 mm pvc box make heavy duty lugs or any reputed brand , mccb 630 amps 50 ka make schneider or abb or siemens or hager or legrand or l and t or indoasian or optipro , mccb 400 amps 50 ka make schneider or abb or siemens or hager or legrand l and t or indoasian or optipro , mccb 250 amps 50 ka make schneider or abb or siemens or hager or legrand or l and t or indoasian or optipro , mccb 125 amps 50 ka make schneider or abb or siemens or hager or legrand or l and t or indoasian or optipro , on load 4 pole change over 63 a make schneider or abb or siemens or hager or legrand or l and t or indoasian or optipro , on load change over 250 a switch , 300 sq mm gland 63 mm heavy duty lugs or any reputed brand , 185 sq mm gland 50 mm heavy duty lugs or any reputed brand , a c box with 20 amps socket socket with sheet steel enclosure plug and mcb make schneider or abb or siemens or hager or legrand or l and t or indoasian or optipro , 10a switch modular make legrand or anchor or abb or mk or schneider or siemens or l and t or l k or kolors or wipro , 16a switch modular make legrand or anchor or abb or mk or schneider or siemens or l and t or l k or kolors or wipro , 6a modular socket make legrand or anchor or abb or mk or schneider or siemens or l and t or l k or kolors or wipro , 16a socket modular make legrand or anchor or abb or mk or schneider or siemens or l and t or l k or kolors or wipro , fan regulator socket type 400w modular make legrand or anchor or abb or mk or schneider or siemens or l and t or l k or kolors or wipro , 2 modular pvc box with plate make legrand or anchor or abb or mk or schneider or siemens or l and t or l k or kolors or wipro , 3 modular box make legrand or anchor or abb or mk or schneider or siemens or l and t or l k or kolors or wipro , 4 modular pvc box with plate make legrand or anchor or abb or mk or schneider or siemens or l and t or l k or kolors or wipro , 6 modular box make legrand or anchor or abb or mk or schneider or siemens or l and t or l k or kolors or wipro , 8 modular box make legrand or anchor or abb or mk or schneider or siemens or l and t or l k or kolors or wipro , 12 modular box make legrand or anchor or abb or mk or schneider or siemens or l and t or l k or kolors or wipro , 2 pole mcb c 10 a schneider or abb or siemens or hager or legrand or l and t or indoasian optipro , 2 pole mcb c 40 a schneider or abb or siemens or hager or legrand or l and t indoasian optipro

Central Government/Public Sector

CTN :45466892 Due date: 16 Jun, 202616 Jun, 2026 NA
Tender For scope of work (sow) as mentioned in tender and schedule of work( 41 )items as given below ,[1] rprg,duct 55.000 to,[2] disman,fab,str 54.000 to,[3] chng,tube of roof 162.000 m,[4] rprg of receiving chute 11.700 to,[5] disman,pipe,manhole 27.000 ea,[6] disman,fab&ern,damaged str 54.000 to,[7] disman,pipe,ms 7.200 to,[8] ern of pipe,ms 7.200 to,[9] rprg of brg housing 68.000 ea,[10] remove & fix cross beam 32.000 le,[11] rprg,car frame 50.000 ea,[12] rprg of platform 14.400 to,[13] ern,bottom stiffeners of ladle 27.000 to,[14] ern,damaged shell of ladle 23.400 to,[15] ern,top shell complete 22.500 to,[16] rprg,trunion of hot metal ladle 11.700 to,[17] rprg,brick retainers in ladle 36.900 to,[18] disman of concrete 32.400 m3,[19] fab,stand,rack,bin&fencing 18.000 to,[20] ern,stand 18.000 to,[21] disman of damaged str 13.500 to,[22] align,cross travel gearbox&mtr 1.000 ea,[23] streng&fixg,side guard plate 9.000 to,[24] disman,co gas pipe 5.000 to,[25] disman,roller,end stopper housing 2.000 to,[26] fitg,trunion by wldg&finishing 4.000 ea,[27] chng,chrgng spout w/bend plate 18.900 to,[28] dism/fab/ere shell of ldl 22.500 mt,[29] dismantl of recup from bottom shell 15.000 mt,[30] rprg,ladle supporting str 11.250 to,[31] rprg,converter shell 27.000 m2,[32] testing of optical fiber cable 4.000 ea,[33] ultrasonic testng, repaired steel ladle 4.000 ea,[34] rprg,pouring out spout shell plate etc 5.400 to,[35] changing nut,bolt&screw f/centrifuge r20 41.000 ea,[36] ern of steel/slag car main beam etc 9.000 to,[37] fitg,trunion by wldg&finishing 12.000 ea,[38] rprg,brg housing 13.000 ea,[39] ern,cage bracket,link etc 11.250 to,[40] repair,str frame 22.000 to,[41] align,g/box mtr&base 10.000 ea

CTN :45349762 Due date: 09 Jun, 202609 Jun, 2026 2.95 Lacs
Tender For procurement of materials for repair of various components used in the fixing of light poles installed across of the failure different wards within municipal area - 61.13 p/l of double wall corrugated hdpe pipe confirming to is 16205 p-24, stiffness class 750 n, externally corrugated and having smooth surface inside with hdpe coupler, elbow, tee at required depth below the ground for laying cable of following nominal outer dia. mfr test report from nabl accrediated is to be submitted. (excavation of earth & back filling with compaction is to be paid extra) all as per pre approved by engineer in-charge.. for additional technical parameters of products/ work, refer annexure "a" attached with this bsr 50mm dia. , providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed unarmoured copper cable confirming to is:1554 p-i / is:7098 p -i of 1.1 kv with electrolytic grade copper made of copper rods confirming to is 613-1964, of purity >99.7%, inner/outer sheath confirming to is:5831 in existing rcc/hume/stoneware / pvc pipe/open duct/cable trench/cable tray (with cable tie) including testing etc. as required of following size. oem must have it's own in house nabl accrediated laboratory for testing procedure as per is:10810 for additional technical parameters of product / work refer annexure 'a' attached with this bsr 3 core , supplying and making one end termination with nickel plated heavy duty brass single compression gland (as per is 12943-1990)) sibg type consisting of check nut, gland body, metal washer(3 nos.), outer seal rubber ring, compression nut, heavy duty aluminium lugs (as per is 8309-1993) duly crimped with crimping tool, pvc tape as per is 8337-1976 of following size of pvc insulated & pvc sheathed/ xlpe aluminium conductor cable of 1100 volt grade as required.all as per pre approved by engineer in-charge. for additional technical parameters of products/work, refer annexure "a" attached with this bsr 4 x 10.0 sq.mm pvc tape roll , supply and fixing of following lt supporting accessories with nut bolt & clamps made out as per standard discom's specifications with two coats of red oxide and two coats of aluminium paint etc. as required. all as per pre approved by engineer in-charge.for additional technical parameters of product / work refer annexure "a' attached with this bsr type a lt connector for aerial bunched cable each 73.00
 Loading, Please wait...

Connect us via What's Up