Get complete information related to latest Ms Pipe Line Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ms Pipe Line Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ms Pipe Line Tenders.
Tender For repairing of mspipeline 200 mm dia. from river bed pump to chp of hloc mine , hlsa including soil excavation and replacement of damaged pipe.
Tender For providing of custom bid for services - dismantling of two numbers of 8 inch 200mm dia m s pipeline of length 1200 mtrs each total length 2400 mtrs from its existing pipeline north side of sump and installation of two number of 8 inch 200mm dia m.s. pipeline of..
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - dch noida oxygen gas pipeline; dch noida oxygen gas pipeline; service provider
Tender For supply of shifting of pac units from jaisalmer to sardarpura and basni jodhpur - supplying of 0.63mm thick gss sheet , supplying of 0.80mm thick gss sheet , supplying of 1.00mm thick gss sheet , sitc of gi volume control damper , supplying and fixing of powder coated extruded aluminium return air grills with louvers , supplying and fixing of 4x16 sqmm power cable , supplying and fixing of control cable of 3x2,5sqmm , sitc of 40mm upvc pipe , sitc of 20mm upvc pipe , sitc ms cable tray 100mm width x 50mm x 1.6mm thickness , sitc ms cable tray 150mm width x 50mm x 1.6mm thickness , sitc of gi strip for loop earthing , dismantling and removing the existing laid old power or control cables , dismantling the existing old package units , recovering the existing laid refrigerant piping of old defective , dismantling the existing old ducts of package units , transportation of the existing fitted old dissmantled package a.c. units , itc of 7 tr sensible high precision ac package unit , supplying and charging of the referigerant gas r-407 , supply and fixing liquid line filter drier , supply and fixing of size 1-1 by 8 inch and 18 gauge copper referigerant pipe , supply and fixing of size 7 by 8 inch and 18 gauge copper referigerant pipe , supply and fixing of size 5 by 8 inch and 18 gauge copper referigerant pipe , laying of 1-1 by 8 inch recovered copper referigent pipe , laying of 7 by 8 inch recovered copper referigent pipe , laying of 5 by 8 inch recovered copper referigent pipe , providing ms structure for outdoor or indoor units , itc of 100mm width x 50mm x 1.6mm , itc of 150mm width x 50mm x 1.6mm , itc of old recovered 4x10 sqmm cable , itc of old recovered 4x1.5 sqmm cable , laying of existing 25 mm x 5 mm thick g.i. strip bid number/ & ( * ) : gem/2025/b/6140065 dated/ + : 15-04-2025 bid document/ 3 3 1 / 29
Tender For repairs and strengthening of badly damaged road with cc from br gas to ghmc stores ( manjeera pipeline road) in hafeezpet ward no.109, chandanagar division-21, slpzone, ghmc
Tender For annual maintenance of central oxygen gas pipeline system maintenance of ot lights and connected accessories at 153 gh under age emii of ge 865 ews
Tender For corrigendum : supply and installation of electrical fixtures and gadgets in bolpur ib at bolpur under burdwan zone in west bengal. - supply & delivery of 3 phase 415v fixed speed cassette type air-conditioner machine having cooling capacity not less than 14100w, eer 2.7 to 3.2, noise level not more than 56db. this cassette type air conditioning machine should be fitted with scroll compressors, lcd remote & all other accessories suitable for refrigerant-r32/r410a. (make-o-general /mitsubishi electric/mitshubishi heavy industries as per approved by eic/authority)., supply & delivery of 240v split air-conditioner machine having cooling capacity not less than 6875 w, isser 3.8 to 4.39, bee rating not less than 3 star, noise level not more than 46db. this split air conditioning machine should be fitted with rotary compressors, lcd remote & all other accessories suitable for refrigerant-r32/r410a. (o-general /mitsubishi electric /mitshubishi heavy industries as per approved by eic/authority)., installation, testing & commissioning of the above-said split ac outdoor unit on existing iron structure and indoor unit on wall & mending good the damages as per direction of e.i.c., installation, testing & commissioning of the above-said split ac outdoor unit by fixing iron angle unit on wall & mending good the damages as per direction of e.i.c., supply & installation of extra add-on items- hvac grade 5/8"(for suction) & 3/8"(for discharge) 1.15mm thickness copper refrigerant pipe with 9mm thick nitrile rubber insulation including shaddle,screw, insulation tape, fastner etc for above ac machine as per direction of eic., supply & installation of extra add-on items- hvac grade 5/8"(for suction) & 1/4"(for discharge) copper refrigerant pipe with 9mm thick nitrile rubber insulation including shaddle,screw, insulation tape, fastner etc for above ac machine as per direction of eic., supply & installation of extra add-on items- hvac grade 1/2"(for suction) & 1/4"(for discharge) copper refrigerant pipe with 9mm thick nitrile rubber insulation including shaddle,screw, insulation tape, fastner etc for above ac machine as per direction of eic., supply & laying of 4core 2.5sq.mm 1.1 kv insulation grade sheathed cu cable with gas line as per direction of eic for making interconnection/communication between indoor to outdoor unit of split type ac m/c.(make- havells/finolex/polycab as approved by e.i.c), supply and laying 5/8(20mm) heavy type pvc pipe for water drainage., supplying, fabrication & fixing of iron stand of m.s. angle size (40 mm x 40mmx6mm) for installation of outdoor unit of 4.0 tr split ac incl. drilling 2 nos holes in each angle and horizontal angle angle 40 mm x40mm x 6 mm in each stand. each stand will be properly fixing by supporting angle (25x25x5mm) and flushnut on peripheral wall as per machine configuration & load with adequate service access as per direction of eic, supplying and fixing 415 v four pole mccb of breaking capacity 25ka/35ka with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing dbs / enclosure and necessary connection (a) 160 amp fp mccb (make legrand/crabtree/siemens/l&t/ abb as approved by e.i.c) [d-8/10], supplying and fixing 240/415 v mcb of breaking capacity 10ka & c characteristics on din rail of existing dbs and necessary connection (make legrand/crabtree/siemens/l&t/abb as approved by e.i.c) [d-6/7] (a) 6-32 amp tp mcb, distribution wiring in 1.1 kv single core stranded fr pvc insulated & unsheathed copper wire (brand approved by eic) in 20mm size pvc rigid conduit fr (precision make) incl. necy. fittings as required[e-14] i) 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ecc [e-14/ 1(a)(iii)], s & f 3phase 9-15a , 415 v dol starter (make-l & t ,cat no. ss94351 or equivalent model of abb/siemens as per dierction of e.i.c) to be fixed on wall with all fixing accessories complete as