Web Analytics Made Easy - StatCounter

Ms Stay Clamp Tenders

Get complete information related to latest Ms Stay Clamp Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ms Stay Clamp Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ms Stay Clamp Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :40950140 Due date: 21 Jul, 202521 Jul, 2025 NA
Tender For empanelment of firms for supply of greenhouse material and repairing of greenhouses - replacement of existing poly sheet on roof, sides, entry gate, corners, etc. , replacement of profile (aluminum material) , replacement of profile (gi material) , replacement of spring (gi) , replacement of thermal net under the roof (50%) , replacement of shade net under the roof (50%) , replacement of supporting wires (3mm) for thermal/ shade net , replacement of pulleys for thermal/ shade net , replacement of pulling rope for thermal/ shade net (plastic material, 8-10mm thick) , replacement of plastic locks for thermal/ shade net , replacement of insect proof uv stabilized on all ventilation portions. , replacement of rolling pipe for side vents (27mm) , fitting material-curtain clamps (2mm thickness) , replacement of cooling pads (26 ft 6 inch) , replacement of alloy aluminium frame water recirculation system for cooling pad (86 ft 6inch) , replacement of pvc drain pipe for water recirculation system in cooling pads (63-90mm as per requirement) , replacement of gutter (2mm) , replacement of rain water gutter end cap (dia. 4) made from gp sheet duly machine fixed with gi clamp nut bolt with pvc drain (at the end) , replacement of axial fans(1250mm, 1.5hp) , supply and installation of air circulation fans (400-500mm dia. ss body, sealed motor, air capacity 4400 cfm) , replacement of polycarbonate sheet (6mm) all sides and top , replacement of existing poly sheet on roof, sides, entry gate, corners, etc. , replacement of profile (aluminum material) , replacement of profile (gi material) , replacement of spring (gi) , replacement of thermal net under the roof (50%) , replacement of shade net under the roof (50%) , replacement of supporting wires (3mm) for thermal/ shade net , replacement of pulleys for thermal/ shade net , replacement of pulling rope for thermal/ shade net (plastic material, 8mm thick) , replacement of plastic locks for thermal/ shade net , replacement of insect net , replacement of bottom apron (160gsm, 1.5 m wide) , replacement of trellising system , replacement of gutter (2mm) , replacement of side vent rolling pipe (27mm) , fitting material-curtain clamps (2mm thickness) , replacement of rain water gutter end cap (dia. 4) made from gp sheet duly machine fixed with gi clamp nut bolt with pvc drain (at the end) , replacement of four-way foggers (28lph) , drip line dia. 16mm, in-line emitters with 30cm spacing, flow rate 2lph

State Government

CTN :40398381 Due date: 04 Jul, 202504 Jul, 2025 NA
Tender For corrigendum : empanelment of agencies for supply of laboratory instruments for various water testing laboratories under jal jeevan mission, assam - ion meter with electrode and accessories for fluoridemeter: ph/ise benchtop meter with electrode stable, universal power adapter, literature, pc cable, meter test certificate electrode: ionplus fluoride and nitrate combination ion selective electrode, 1m cable, waterproof bnc benchtop ion meter (ise) along with fluoride, nitrate #electrode range: -2.000 to 20.000 resolution 0.1, 0.01, 0.001 relative accuracy 0.002 calibration points up to 5 calibration editing yes #mv/ rmv orp range 2500.0 mv resolution 0.1 relative accuracy 0.2 mv or 0.05 % of reading whichever is greater eh orp mode yes ise range 0 to 19999 resolution up to 3 significant digits relative accuracy 0.2 mv or 0.05 % of reading whichever is greater units ppm, m, mg/l, %, ppb, none calibration points up to 5 calibration editing yes calibration features timed end point, linear point to point, non-linear selectable auto-blank, low concentration range stability #temperature range -5 to 105 c, 23 to 221 f resolution 0.1 relative accuracy 0.1 offset calibration 1-point datalogging memory 2000 with time and date stamp log function manual, ready (include auto-read ), timed log edit delete individual points, group of points or all inputs ph electrode bnc, reference pin atc probe 8-pin mini-din #output rs232, usb power ac adapter included universal, 100-240 vac battery power optional 4 aas battery life 800 hrs, fluoride electrode of ion metersame make that of the ion meter, manifold filtration assembly* wide range of pumps and filtration flasks * high quality components * easily exchangeable elements *maintenance-free * low noise * added filters for enhanced pump longevity * filtration base with silicon stopper, cap & aluminium clamp connecting silicon tube technical specification for filtration flask set # high-pressure resistant tube # fiberglass filter membranes (47mm / 0.1 m) # ptfe disc filter #normal liquid filtration * specification for filtration glass set #suction bottle capacity(ml) 1000 ml # filter diameter(mm) 47/50 mm # * specification for filter flask * material: statinless steel 304, capacity: 300 ml (100 ml each) [ unit should consist of 3 flask so that 3 sample can be filtered simultanelously without any issue] # effective filtration area(cm2) = 9.6 cm2, outlet connector(mm) = 8 mm * specification for vaccum flask: #flow rate of the pump(l/min) = 17 l/minultimate vacuum(mbar) = 150 mbar # oil free, maintainance free, built in thermal protection to shut off when over heated., auto cut heater for distill water plant so that when water level decreases the heater is switch off automatically, voltage stabilizer capacity- 3 kva servo stabilizer 5 star rating, heating mantle (single station) should have digital energy regulator with multiple step power regulation automatic spill detection and saftey shutdown in built precision temperature control technial specification: flask capacity 250 ml, working temp range: ambiant + 5 to 420 degree celcius. accuracy: plus minus 1.0 degree celcius, power consumption : 150 w, heating mantle (combined unit) material of construction heating block: made with grade epoxy painted chemical resistant coating, aluminum block with 6 thermo wells for processing 6 different samples at a time. #racks: ss 316 # glassware: teflon coated # temperature range ambient + 10 deg c to 450 deg c # stability of temperature better than 0.5 deg c # controller consist of digital read out of temperature and time with 4 programmable ramps for each method. # number of programmable methods 20 numbers. # heating powers 1000w # heating position minimum 6 position # digestion time range -1 to 999 minutes # the system should have facility of acoustic signal at the end of completion of cycle to notify the operator. # the thermal digestion unit should have high thermal homogeneity # the setup should have small f

CTN :40679310 Due date: 03 Jul, 202503 Jul, 2025 5.07 Lacs
Tender For corrigendum : supply of various types of 132 kv current transformer terminal clamps, bus isolator clamp, bimetallic strip, aluminum base, copper- brass terminal end clamp and jaw assembly and associated accessories for 132 kv switchyard at rpsps, jsps.
 Loading, Please wait...

Connect us via What's Up