Web Analytics Made Easy - StatCounter

Ms Tray Tenders

Get complete information related to latest Ms Tray Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ms Tray Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ms Tray Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government And Public Sector

CTN :40343928 Due date: 06 Jun, 202506 Jun, 2025 5.09 Lacs
Tender For tender for supply of shifting of pac units from jaisalmer to sardarpura and basni jodhpur - supplying , installing , balancing and commissioning of fabricated at site gss sheet metal rectangular/ round ducting complete with neoprene rubber gaskets , elbows , splitter dampers , vanes , hangers , support as per approved drawing and specifications of 0.63mm thick gss sheet etc complete as required. , supplying , installing , balancing and commissioning of fabricated at site gss sheet metal rectangular/ round ducting complete with neoprene rubber gaskets , elbows , splitter dampers , vanes , hangers , support as per approved drawing and specifications of 0.80mm thick gss sheet etc complete as required. , supplying , installing , balancing and commissioning of fabricated at site gss sheet metal rectangular/ round ducting complete with neoprene rubber gaskets , elbows , splitter dampers , vanes , hangers , support as per approved drawing and specifications of 1.00mm thick gss sheet etc complete as required. , sitc of gi volume control damper complete with neoprene rubber gaskets , nuts , bolts , screws linkages , flanges etc. as per specifications etc complete as reqd.. , supplying & fixing of powder coated extruded aluminium return air grills with louvers but without volume control dampers complete as required. , sitc of 4x16 sqmm pvc insulated pvc sheathed aluminum conductor armoured cable on the existing ms tray /walls with saddles/pvc of cables with glands etc. as required , sitc of 3x2.5 sqmm pvc insulated pvc sheathed copper conductor armoured cable for control wiring on the existing ms tray / walls with saddles/pvc thread/cable tie , screws etc. i/c end termination of cables with glands etc as required. , sitc of 40mm upvc pipe for plumbing work for drainage requirement i/c reducer , elbows , tees , unions , bends , sockets , flanges etc. for making water line connection forvarious package units of system etc. complete as required. , sitc of 20mm upvc pipe for plumbing work for drainage requirement i/c reducer , elbows , tees , unions , bends , sockets , flanges etc. for making water line connection forvarious package units of system etc. complete as required. , sitc of 100mm width x 50mm x 1.6mm thickness size of perforated ms cable tray i/c fabricating i/c horizontal and vertical bends reducers tees , cross members and other accessories as reqd , and duly suspended from the ceiling with ms suspenders and including paint etc. as required. , sitc of 150mm width x 50mm x 1.6mm thickness size of perforated ms cable tray i/c fabricating , horizontal and vertical bends reducers tees , cross members and other accessories as reqd , and duly suspended from the ceiling with ms suspenders and including paint etc. as required. , sitc 25mmx5mm thick g.i. strip for loop earthing on cable tray wall etc complete as required , dismantling & removing the existing laid old power/control cables of booster fans , old package units , condenser units , heaters/pre-heaters system , humidification etc. complete by unscrewing/cutting from the related m.s. racks/tray as required , lowering down the same from different floor to ground floor & shifting the same to the place inside the exchange premises as directed by eng.-in-charge. , dismantling / removing the existing fitted old defective/working/ /worn out 05 nos.package a.c. units with related condensers & accessories like canvas connection , duct damper & place at out side ac plant room at same floor etc as directed by eng.-in-charge. , recovering the existing laid refrigerant piping of old defective/working / worn out hot gas & cold gas of different sizes complete by cutting/unscrewing /opening etc. fitted in between the package unit & condenser unit lowering down the same from different floor to ground floor and shifting the same to the place inside the exchange premises/keeping in safe custody as directed by eng.-in-charge. , dismantling the existing old ducts of pac

CTN :40268022 Due date: 29 May, 202529 May, 2025 NA
Tender For supply of wind sensor bird spike kit , mfcr , psu mfcr , marine connector , ots wsds mfcr v22 , awos miu
 Loading, Please wait...

Connect us via What's Up