Tender For bid to ras supply of procurement and installation of rfid based access control system for entry management - vehicle scanning reader 15 mtrs range including pole and pole mount bracket , programmable logic controller for in and exit gate , industrial server system high end support rapid read zebra application , real time display count with web application , identification for four wheeler vehicles , identification for two wheeler 3m outdoor weather proof , industrial hand held reader long range reader with built in battery , ai camera android application on handheld device , parking management software web based real time data acquisition for all type of vehicle count , civil, fabrication pole and electrical works , installation training and commissioning including wires network and power switches
Tender For dental equipments / instruments - 3 point articulator/plane articulator (mean value articulator), acryliser programmable preheating time & temperature programmable curing time & temperature analog control unit capacity-6-8 flask digital programming, adson tooth forceps 5 , adsons tooth forceps 8 , advance digital microscope with imaging software (with desktop + printer + ups + mouse) optical system- infinity color corrected optical system observation tube: seidentopf digital viewing head, 3.2 million pixels high resolution camera system resolution ratio 2048*1536 pixels, line by line scan eyepiece: high eye point wide field plan eyepiece pl10x/20mm, with 5 degrees diopter control, ipd: 50-75mm objective: plan achromatic objective 4x plan achromatic objective 10x plan achromatic objective 40x spring plan achromatic objective 100x s, oil nosepiece: backward quadruple nosepiece illumination- main supply 100v-240v, 3 watt led lamp or 6v/20w halogen with intensity control (fixed center focusing adjustment: coaxial coarse and fine focusing adjustment, with limited and tension adjustment coarse adjustment range: 25mm fine adjustment precision 0.002mm. condenser: n.a.1.25 condenser (with socket for phase contrast and dark field sliders) stage: coaxial mechanical stage 140x132mm size and 76 50mm travel range. inbuilt microscopic scientific digital camera with imaging software consisting of: high resolution digital camera with 1/2 cmos chip usb 2.0 pc connection real time live image resolution: 3 mega pixels electronic shutter exposure time: 1ms-0.3s working temperature: -20 c ~ 70 c image analysis software: sportily calibration line measurements for distance, length, width, perimeter, angle, three point radius. area by enclosed line controlled by four arrow keys available on the keyboard arrow with zoomed preview the line measurement is not affected on zoomed images. identification of objects in an image, count them, obtain several features measurements. objects identification by user or automatically. user defined classification on basis of size or intensity. manual, auto bright and auto dark methods to identify intensity range defined object to be measured. various calculation & measurements available for selected particle are; dimensions, area, perimeter, ferrite length, min/ max radius, thread length, thread width, fiber length, fiber width. roundness, shape, orientation, elongation, equal circular diameter, equal sphere volume, data export report generating and print out interactive file format., agate spatula, air conditioner, air purifier, airotor cartridge suitable for nsk airotor hand piece, airotor control box with inbuilt micromotor , 3 way syringe & 02 nos. airotor control with trolly, airotor hand piece (chuck), airotor hand piece noiseless ultra push type with ceramaic bearing super torque head, airotor oiling machine, alcohol torch with adjustable flame, alginate mixing spatula, allis forcep 5 , allis forcep 6 , alloy cutter compact alloy cutter with high speed grinding and dependable trouble free operation with vaccum suction safety glass for glare elimination and visual protection 20000 rpm, amalgam carrier, amalgamator, anesthesia machine (boyle apparatus) 1. ms & aluminum combined structure with polyurethane coated finish for long life. 2. forged body regulators for medical oxygen & nitrous oxide for maintenance free operation. 3. two numbers each forged yokes with ss fittings for medical oxygen & nitrous oxide at the sides. 4. colour coded yoke mounted high pressure gauges. 5. two tube rotameter with oxygen ratio controller with unitized rotameter. 6. magill s breathing system one number in addition. 7. bain s breathing system one number in addition 8. safety features : oxygen failure warning device (ofwd) nitrous oxide cut off in the absence of oxygen oxygen ratio controller 9. large diameter castor wheels with individual brakes at front castors 10. one year standard warranty 11. local s
Tender For e-tender (2nd call) for procurement of laboratory instruments, equipment, appliances for the college of veterinary sciences and ah, rk nagar under the nec funded project for the year 2025-2026 - biosafety cabinetclassii, a 2 with accessories and power back up (bacteriology)-- the biological safety cabinet should be of class ii, type a2 designed in compliance with international standards the biological safety cabinet quoted instrument model must have international standards test likensf, tuv nord, en 12469 certification. certificate copy must be provided along with the technical bid. working area should be around 4foot. it should have exterior dimension w x h x d of 1300x 1568 x 800 and interior dimension wxhxdof 1200x 780x 630 it should have 1 piece grade 304 stainless steel or thermos scientific smart coat interior itshouldhavefeatureforpersonalprotection,sample protection, cross contamination protection and environmental protection. it must utilize brushless dc motor technology which uses significantly less energy with less heat emission provision compared to traditional ac motor technology to ensure lower levels of energy consumption. it should have 10 sloped front for exceptional comfort and ergonomics thesystemshouldbedesignedwithdualmotor. the motor must automatically adjust or control fan speed in real time to maintain constant airflow during filter loading or temporary obstruction. air flow direction: vertical laminar flow & air intake across front opening and 70% recirculation. filter: high performance particle air filter h14(hepa en1822), filtering efficiency 99.995% mpps or better. energy saving mode when cabinet not in use with maintaining sterility. continuous airflow helps to maintaina sterile environment, evenwhen the cabinet is not in use. thesystemshouldhaveindependentsensorstodetect pressure changes across the exhaust and down flow plenum/ air velocity and should indicate alarm signal when a 20-30% change in inflow/ exhaust or down flow occurs. control panel and performance monitor displays inflow/ down flow velocities, hours of use etc. to verify proper cabinet operation. frontglasswindowshouldbeeasilyloweredfor thorough smart cleaning of inner surfaces and designed to protect users by maintaining inflow, even when the window is lowered. the uv light must be quoted which should be programmable from 30 min to 24 hrs. in minimum 30 minutes increment to shut off automatically. the settings must allow the user to program the timer. the cabinet noise level must be less than 63 db(a) as measured in a sound proof room to promote more comfortable and safer working habitsof the user a per nsf/ ansi 49. the controller must be located on a slanted frontpanel so it is easy to see from a seated working position in front of the cabinet. control panel should be a large digital color touch screen display with health monitoring system, valuable safety and performance data with constant read-out of downflow/ inflow velocities and hours of operation in real-time, number of hours of use on the hepa filters. the front window sash must be angled 10 sloped front for operator comfort. two pieces of removable and autoclavable stainless steel arm rest should be provided for operator s comfort without disturbing the air flow. the system must have audio visual alarms to indicate when inflow is restricted and as well as whether front window is in correct position or not. theworkareashouldbeilluminatedwithswitchable fluorescent lamp of lighting power >120 fc or higher. suitable height floor stand without casters should be provided. in built access ports, 2 nos. (1 on each side) shouldbe available. it has single piece stainless steel work tray for easy cleaning and decontamination. warranty:minimum3year. electrical supply available: 230v a.c, single phase, 50 hz. bidder should provide printed brochure of the quoted model and details specification should be available in the manufacture website. customized model would not be accepted wi