Web Analytics Made Easy - StatCounter

Mv Panel Tenders

Get complete information related to latest Mv Panel Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Mv Panel Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Mv Panel Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government And Public Sector

CTN :45704062 Due date: 06 Jul, 202606 Jul, 2026 5.16 Lacs
Tender For supply of modernization of distribution infra 2x400 kva substation companybagh b b -dismantling and refurbishing of electrical distribution system , itc of existing load bank with static meter , itc of existing load bank , trimming and pruning of four trees , transportation of one dismantled lt panel darbhanga to mzp , removing of old faulty outlived mv panel , provision of structural iron channels mounting framework for the lt panel , re-furbishment of existing mv panel , brickwork for minor structural alterations near the lt panel support base , straight through joint 185 , straight through joint 50 , removing and relaying of existing cement interlocking bricks , laying of 1.1 kv grade of 35 sqmm to 185 sqmm direct in ground , dressing of cables , finishing of the lt bus bar box , 20w surface-mounted led tube light , a. horizontal type tpn db 8 way with double door , b. horizontal type tpn db 8 way single door , a. vertical type, 415 v, tpn db 8 way double door , dressing of dbs , a. single pole mcb 6 to 32 a , b. four pole isolator 63 a , c. four pole isolator 40 a , d. double pole isolator 40 a , e. tp mcb 63 a , f. 125 a tp mccb 16 ka , 3 pole mccb of 250a, 25 ka , itc of existing lt bus bar box , sitc wall mounted heavy-duty air circulators fans of 600mm metal blades , supplying and fixing of 5mm thick m.s.chequered plates , fixing of ms stand of pac outdoor unit , providing double coat spray painting , sign writting numbering on all panel proper marking of its connectivity , a. wiring for light point group-a , a. copper conductor, single core cable 2 x 1.5 sq. mm , a. medium class pvc conduit 20 mm , shifting re- installation of submersible pump staters , making opening of wall to suit the size of 380 mm sweep exhaust fan , supplying fixing of exhaust fan of 380 mm sweep heavy duty , a. blanking plate , b. 5 pin 15 a socket , c. 15 16 a piano type switch , d. 5 6 a piano type switch , e. 3 pin 5 6 a socket outlet , f. 3 pin 15 a top , g. wall fan , h. down rod for ceiling fan installation 3 ft length hook , a. 100 watt flood light , b. 24 w led rimless surface panel light , sitc of 100 a 3 phase neutral copper bus bar in sheet steel enclosure , dressing of existing distribution system of type ii staff qtr , itc of 100 a 3 phase neutral bus bar with 100 a mccb in sheet steel enclosure , supplying fixing of double pole spn mcb 32 a in the sheet steel enclosure , s l 2 1.5 sqmm copper conductor , removing the faulty lt cable of size 3.5 core 240 sq.mm , ms clamp on four pole structure for fixing the ht cable , extracting of spare main ht cable 11 kv 95 sq mm size from the soil , extracting of faulty spare ht cable 95 sq mm from the duct manual labour , fastners nut bolt, al lugs, socket, cu lugs socket, washers, screw, pvc clips , acrylic sheet of 2 mm thickness , hrc fuse of 200 a //bid details 2 / 49

CTN :45438320 Due date: 06 Jul, 202606 Jul, 2026 45.00 Lacs
Tender For corrigendum : supply of providing and laying of painting works , patch works , waterproofing works , dismantling false ceiling , dismantling bison board , dismantling woden partistion , window closing , dismantling existing washbasin , cleaning , room 3 , providing toilets , toilet renovation works , roofing and false celing works , room 9 , floor patch works , dismantling of toilets , dismantling damaged windows , room 14 15 , dismantling existing doors , repairs to existing ventilator windows , dismantling existing wall and floor tiles , structural repair and opening modification works , dismantling brick structure and floor repair , dismantling and vegetation removal , dismantling existing broken and damaged glass panes , cpvc water supply line , site clearance and general demolition works , anti termite treatment , rodent and pest control treatment , overhead water tank cleaning repair and disinfection , storm water drain and surface drainage , signage and room identification , comprehensive checking of 1 nos 250 kva outdoor type substations including inspection , aluminium paint , servicing of existing 11 kv 400 amps 3 pole gang operated type air break ab switch , supplying and replacing damaged or worn out copper metal , supplying and replacing damaged or defective 11 kv post top insulators , supplying and replacing damaged or defective 11 kv pin type insulators , servicing of earth pits , supply installation testing and commissioning lbs , xlpe insulated aluminium conductor armoured ht cable , providing indoor or outdoor type heat shrinkable , supplying and laying of 3.5 core x 240 sq.mm 1.1 kv grade aluminium conductor xlpe insulated , supplying and making end termination for 3.5 core x 240 sq.mm 1.1 kv grade , joint for existing single run lt power cable of size 3.5 core x 240 sq.mm , comprehensive servicing and preventive maintenance of existing ht transformer , supply, fixing, installation, testing and commissioning of lightning arrester , providing and fixing cable identification tags , supply, installation, testing and commissioning sitc main mv panel , supply, installation, testing and commissioning sitc cubicle pdb panel , supply, installation, testing and commissioning sitc feeder pillar box , providing and installation of maintenance free earthing station , supplying and laying of 3.5 core x 120 sq.mm 1.1 kv grade aluminium conductor xlpe insulated , providing laying and fixing of overhead perforated or slotted ms cable tray , supply installation testing and commissioning 7 segment distribution board , providing fabricating supplying, installing testing and commissioning of electrical socket box

Central Government And Public Sector

CTN :45279869 Due date: 29 Jun, 202629 Jun, 2026 2.90 Lacs
Tender For bid to ras corrigendum : supply of service 11 kv ht panel as per sepcifications , sf new mineral oil for panel etc as per sepcifications , calibration relay etc as per sepcifications , replacement digital ammeter for ht panel , replacement digital voltmeter for ht panel , replacment ryb ind lamp led type in ht panel , sf 2a hrc fuselink in ht panel , servicing 1500kva dry type transformer as per sepcifications , servicing 2 runs 2500a tpn bustrunking as per sepcifications , service mv lt panel with 2500a 4p acb 3 nos as per specifications , service mvlt panel with mccb incoming as per specifications , checking and repair of em intelocking , dismentaling 3.5 sq mm 240 or 300 sq mm al cable as required , pf adaptor box aprx 1.5 ft x 1.5 ft x 1.5ft of 16swg ms sheet as reqd , pvdg panel module door key as reqd , pvd and fixing operating handle for 250a 4p changeover as reqd , replacement 160a hrc fuse with base in extg cap panel , replacement 3p 50kvar cap duty contactor in extg cap panel , replacement 25sq mm cu lead wire 1ft length in extg cap panel , checking etxg 2no 25kvar cap bank and fault repair reinstallation , dismentaling uv protection connections as reqd , replacement digital ammeter for lt panel , replacement digital voltmeter for lt panel , replacment selector switch in lt panel , replacment ryb ind lamp led type in lt panel , sf 2a hrc fuselink in lt panel , sf 32a hrc fuseling incl removing faulty item from lt panel as reqd , sf 63a hrc fuseling incl removing faulty item from lt panel as reqd , sf 100a or125a hrc fuseling incl removing faulty item from lt panel as reqd , sf 250a hrc fuseling incl removing faulty item from lt panel as reqd , sf new 5 or 6 amp piano switch in replacement of faulty item , sf new 5 or 6 amp 3pin socket outlet in replacement of faulty item , sf new 15 or 16 amp piano switch in replacement of faulty item , sf new 15 or 16 amp 6pin socket outlet in replacement of faulty item , rewinding ceiling fan motor , sf 4ft 20w led fitting against faulty fitting , service of 750kva dg set as per specification , service dgset control panel 1250a 4p acb as per specification , repacement ryb ind lamp in dg set panel , repacement digital ammeter in dg set panel , earthing testing in existing earth pits and report submission

Central Government / Public Sector

CTN :45502151 Due date: 01 Jul, 202601 Jul, 2026 95.63 Lacs
Tender For corrigendum : combined station works for installation testing and commissioning (sitc) of medium voltage (mv) panels (06 nos.) for nrpl stations

CTN :45656593 Due date: 26 Jun, 202626 Jun, 2026 48.44 Lacs
Tender For repair and renovation of existing hostel building of sammakka sarakka central tribal university, jakaram, mulugu district, telangana state. sh: repairs and renovation of rcc works, brick works, floorings, toilets, providing cup boards, external painting of toilets and compound wall, ms grill works, parking shed ms works, paver blocks, signages, epoxy paining for ms works, pvc water tank, ss railing including dismantling of doors, tile work, old plaster work, wcs, mcb dbs, electrical tube light fittings, street lights, mv panel with gi earthing etc.

State Government

CTN :45515295 Due date: 09 Jul, 202609 Jul, 2026 1.80 Crore
Tender For operation and maintenance of diesel generator set iof capacity 2x750 with synchronization panel, allied equipment, 11 kv breaker panel with compact rmu, electrical substation with 2x1000 kvatransformer 11kva/433 volts mv panel and internal electrification and periodical services of electricalinstallations at sjicr, kalaburagi

CTN :45362415 Due date: 04 Jun, 202604 Jun, 2026 10.12 Lacs
Tender For construction of new kitchen for opal mess at nit, trichy. sh: building portion including water supply, sanitary installation, aluminium work, water proofing, including internal electrical installations, lightning conductors, external service (mv panel & ug cabling), emergency light & illuminated signages, solar water heater, ro plant, water coolers, firefighting with down comer system, manual fire alarm system, kitchen ventilation system and external lighting additional works for opal mess kitchen. sh: providing and fixing of wall tiles, floor tiles & other miscellaneous works in the existing new kitchen for opal mess.

CTN :45269752 Due date: 27 May, 202627 May, 2026 10.12 Lacs
Tender For construction of new kitchen for opal mess at nit, trichy. sh: building portion including water supply, sanitary installation, aluminium work, water proofing, including internal electrical installations, lightning conductors, external service (mv panel & ug cabling), emergency light & illuminated signages, solar water heater, ro plant, water coolers, firefighting with down comer system, manual fire alarm system, kitchen ventilation system and external lighting additional works for opal mess kitchen. sh: providing and fixing of wall tiles, floor tiles & other miscellaneous works in the existing new kitchen for opal mess.

State Government

CTN :45173467 Due date: 23 May, 202623 May, 2026 NA
Tender For renovation of existing electrical supply infrastructure by ug cables for restoration of power supply to the entire depot complex,godowns and ancillaries, including design,fabrication, supply, installation, testing and commissioning of fp boxes,replacement of mv panel improvements to lighting

State Government

CTN :45046874 Due date: 08 May, 202608 May, 2026 12.36 Lacs
Tender For 1)inspection of stator coil for identification of exact no. of the faulty coil and setting up the arrangements for rotor pole coils removing and rotation as per scope of works along with supply of materials and other consumables as per scope of works2)de-brazing the rotor pole terminations and removing the rotor poles (as required). dismantling of rotor poles using suitable and compatible tools, fixtures, and lifting arrangements. ensure safe handling and proper marking for reassemble. rotate and position the rotor appropriately to access the damaged stator coil area.3)remove insulation from both ends of the affected winding section.4)de-brazing of defective coils. 5)driving out the slot wedges carefully remove wedges from stator winding slots without damaging adjacent coils or core.(entire stator winding shall be inspected in case of loose wedges, worn out wedges and missing wedges shall be replaced) along with supply of materials and other consumables.6)insulation removal- remove insulation from both ends of the affected winding sections.7)cutting the coil bindings in both sides. cut the identified damaged winding portion using appropriate tools. carefully pull out the damaged coil from the stator slots without affecting surrounding windings.8)damaged winding cutting- cut the identified damaged winding portion using appropriate tools.9)winding extraction- carefully pull out the damaged coil from the stator slots without affecting surrounding windings. while removing the faulty coils from stator, utmost care should be taken to prevent any damage to stator core.10)removal of faulty coils from the slot.11)slot cleaning and preparation-clean stator inner tooth slots thoroughly. use emery paper to smoothen and maintain uniform slot condition.12)cleaning of carbon deposits/heavy oil content from complete stator coils through co2 cleaning process /dry ice blasting.13)new coil installation-insert new stator coil with proper alignment. fix securely using new wedges of appropriate grade and size.14)brazing of the coil ends.15)re-fixing the rotor poles and connecting them.16)insulation application-apply insulation as per specified class (e.g. class f/ classh). ensure proper curing and finishing.17)complete co2 / dry ice cleaning of stator and rotor.re insertion of removed rotor poles. 18)final checks & testing- insulation resistance (ir) test, high voltage (hvdc) test, continuity check, visual inspection and any other tests which are required (will be carried out by kpcl).19)assembling of removed damper doors and stator covers.20)maintain quality standards throughout the process & use calibrated tools and approved materials.21)presence of the agency during excitation and synchronization of the unit by kpcl.22)safety & quality-follow all safety procedures and ppe requirements
 Loading, Please wait...

Connect us via What's Up