Get complete information related to latest Mvar Capacitor Bank Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Mvar Capacitor Bank Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Mvar Capacitor Bank Tenders.
Tender For procurement of ece and eee lab equipments - single output regulated dc variable power supply, dual output regulated power supply, function generator, digital storage oscilloscope, dc voltmeter, dc ammeter, decade resistance box, decade capacitance box, decade inductance box, 8051 microcontroller kit, embedded trainer kit using lpc2148, lvdt sensor trainer kit, strain guage trainer kit, temperature measurement trainer kit, sim reader trainer kit, microwave testbench with reflex klystron oscillator, dc series motor with electrical workbench, single phase transformer, three phase transformer, loading rheostat 3 phase, single phase resistive load, three phase synchronous motor with electrical workbench, on/off control of lamp using solid state relay kit
Tender For insulation monitoring relay 110 volts a.c, insulation measuring range 1-100 kilo ohm, control supply 24-240 volts ac/dc output 1c/o (spdt) contact system leakage capacitance 10 micro farad. accepted make: - contrel make ir 140y-4, ri-r22, or abb make-cmiws.1s, or schneider make- vigil ohm/imd-im10, or siemens make- 3ug4581-1aw31 or dold make model no il5880 or woka make or bender make only confirming to rdso letter no: el/7.1.108/mssbc dt:17-09-2021 for common bill of material items. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of insulation control 110v ac, measuring range 1-100 kohm, control voltage 24-240v ac/dc, output 1c/0(spdt) contact system leakage capacitance 10 micro farad as per rdso lr.no.el/7.1.108/mssbc dt.17-09-2021.sn of bom 67 suitable for switch board cabinet of lhb ac coaches of rdso.specn.no. rdso /pe/spec/ac/0192-2018(rev-1). [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of digital lcr meter 3 1/2 digit 1999 counts measuring range inductance l = 20 micro henry to 20 henry(resolution 0.1 micro henry), capacitance c= 200 pf to 20 mf (resolution 0.1 pf), resistance r = 200 ohm to 2000mega ohm (resolution 100 mili ohm) make: kusam-meco or fluke or motwane or similar [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of rf analyzer or spectrum analyzer , sdr system complete usrp b210 and antennas and lna filter kit , rf signal generator , digital storage oscilloscope , logic analyzer , benchtop inductance capacitance resistance meter , smd rework station , esd work benches , precision esd toolkit and microscope , rf cables and adapters kit , vna calibration kit , high end desktop workstation for diagnostics mil grade , c two software , rf shielded enclosure faraday cage , bench power supply , building earth and earthing pit , centralised ups online system , mil grade electrical works , fire and smoke alarm system , rf safety devices , annual calibration year one
Tender For purchase of ece department lab electronics equipments - equipments for ece, dual output regulated dc variable power supplyinput voltage : 230v/50hz acoutput voltage :(0-30)v dcoutput current :(0-2)a dcprotection circuit : over voltage, over current, and short-circuit protectionhigh efficiency : greater than 85%low ripple and noise : less than 50 mvdigital display, function (signal) generatorspecs:frequency range : 0.1hz to 5mhzdisplay :4 to 6 digit led displayoutput waveforms : sine, triangle, square, pulse, rampamplitude :0-20 vpprise time :100 nsdistortion : 1% within specified frequency rangepower supply : 230v ac 10% , 50-60 hzoutput amplifier protection : short circuit and 15voverload protectiondc offset: 0 to 10 v adjustableattenuation: 0 to -60 db, decade resistance box range : 1 to 1m rotary switch selection with 6 dialssteps : 1 , 10 , 100 , 1k , 10 k , 1m accuracy : 1%, decade capacitance box range : 100 pf to 100 frotary switch selection with 6 dialsmaximum voltage : 350vaccuracy : 1%, decade inductance box range : 10 h to 10 hrotary switch selection with 6 dialslow-loss inductorsaccuracy : 1%, sim reader trainer kitpower supply :operates on 230v ac 10%, 50hz mains supplybuilt-in regulated smps power supplyoperating dc supply : 5v/12v with overload and short-circuit protectionsim card interface :supports gsm sim cards compatible with 2g / 3g / 4g / 5g networkssim card read/write interfacesupports sim card initialization, authentication and communication functionscompatible with standard 6-pin / 8-pin sim card socketscommunication interface :usb 2.0 interface for pc communicationrs-232 serial communication interfaceuart communication facility for embedded system interfacingsim operating parameters :selectable sim clock frequencies3.579 mhz7.159 mhz14.318 mhzsim supply voltage selection facilitysim reset and activation controlsupported protocols and standards :gsm etsi 07.07 and etsi 07.05 at command supportiso/iec 7816 smart card communication supportsim communication command monitoring facilityhardware features :on-board sim card socketled indication for :power statussim detectionreset activityuser manualutility software cd / downloadable software packagedata transmission/receptionbuilt-in keypad for standalone operation.lcd display module (128 64) for menu and status display.on-board microcontroller-based control section.software support:at command execution and monitoring software.sim manager utility software.data logging and communication terminal utility.pc-based gui software for sim data communication experiments.trainer features:fault simulation facility for troubleshooting experiments.simulation of faults such as:sim not detectedclock failurevcc failurereset failuremultiple on-board test points for signal observation.test points for:sim rstsim_clksim iovccuart tx/rxsuitable for cro/dso signal monitoring.glass epoxy pcb with educational block diagram layout.compact tabletop enclosed cabinet design.construction:front panel with printed block diagram.banana test points and patching facility.standard accessories:gsm sim trainer unit.usb communication cable.rs-232 communication cable.power cord., microwave test bench with reflex klystron oscillatormicrowave source :relex klystron tube with klystron mountoperating frequency in x-band (8.2ghz to 12.4ghz)electronic tuning through repeller voltage controlsuitable for cw microwave generationklystron powersupply:regulated klystron power supply unitbuilt-in modulation facilityoverload and short circuit protectionoperates on 230v ac 10%, 50hz mains supplywaveguide components:isolator variable attenuatorfrequency meterslotted line section with tunable probecrystal detector mountmatched loadmovable short / terminationwaveguide stands and accessoriesmeasurement unit:solid state vswr meter with high sensitivityswr measurement facilitysuitable for detector output monitoringtechnical specification :frequency range : 8.2 ghz to 12.4 ghzwaveguide types : wr-90detector type : crys
Tender For supply of lcr meter with the following specifications: measurement parameters inductance (l), capacitance (c), resistance (r), quality factor (q), dissipation factor (d), series resistance (rs); input impedanceac and dc voltage 1m ohm, no. of digits in lcr display : 4, measurement range inductance 0.001 microh to 99999h, measurement range capacitance 0.001 pf to 99999 uf, measurement range resistance z, r, x 400 ohm to 40m ohm, measurement range phase angle 0.00 degree to +/- 180.0 degree, measurement range q & d 0.001 to 1999. make: meco model lcr999a or equivalent model in fluke or sonel or megger or gwinstek only. [ warranty period: 30 months after the date of delivery ] ]
Tender For supplying, installation, testing and commissioning of equipments for electrical measurement, electrical workshop, electrical machine & power system laboratory at ttaadc polytechnic institute, khumulwng, west tripura for the project "improvement of infrastructure in ttaadc polytechnic institute, khumulwng, west tripura, district under higher education department” under the nec scheme. (2nd call) - supplying, installation, testing and commissioning of electrical measurement, electrical workshop, electrical machine & power system laboratory equipments/machineries of electrical engineering department at ttaadc polytechnic institute, khumulwng, west tripura under the nec scheme "improvement of infrastructure in ttaadc polytechnic institute, khumulwng, west tripura, district under higher education department." (2nd call), kelvin double bridge trainer kitthe instrument should have following features : easy illustration of kelvins bridge digital display (dpm) for null detection online product tutorialthe instrument should have following technical specifications :dc power supply : +5vknown resistance : r1=100k , 20k , 10k r3=1k , 200 , 100 dpm : 2vdimensions (mm) : 240 w x 345 d x 110 hunknown resistance : 0.3 , 0.4 , 0.8 mains supply : 230 v 10%, 50 hz, whetstone bridge trainer kitthe instrument should have following features :sample : constantan, nichromeprovided with dc power supply compact designeasy to operatethe instrument should have following technical specifications:dc power supply:5vgalvanometerdeflection:30 - 0 30resistance:80 unknown resistance type: variablerange:0 - 10k wire samples: -constantan: 1mnichrome:1mfuse:500mamains supply: 90 - 275v, 50hzdimensions (mm):w 345 x d 240 x h 110, experimentation with de sautys and schearing bridgethe instrument should have following features: - a complete set up with all necessary accessories inbuilt 1 khz sine wave generator with variable amplitude null detector with dpmtechnical specification: -sine wave generatorfrequency range:1khz 10%amplitude control output: up to 15vppfuse:500 ma, s/bdpm:200 mvunknown capacitor:0.1 f, 0.22 f, 0.47 fmains supply:230v ac, 10%, 50hzdimension (mm):w 345 x d 240 x h 110, experimentation with maxwells bridgethe instrument should have following features : illustration of both maxwells inductance bridge and maxwells inductance-capacitance bridge on a single board inbuilt 1 khz sine wave generator with variable amplitude null detector with dpmthe instrument should have following technical specifications :mains supply : 230 v 10%, 50 hzdc power supply : +12v, -12vsine wave generatorfixed frequency : 1khz 5%amplitude control range : upto 20vppunknown inductors : 10 mh, 20mh, 30 mh, 56 h, 24 h, 12 hdpm : 200mvunknown internal resistance : 470w, 10 , 20 , 30dimensions (mm) : w 240 x d 345 x h 110, measurement of three phase active & reactive power with single phase wattmeter technical specifications:analog meters: analog voltmeter, range : 300v analog ammeter, range : 2a analog wattmeter power supplies: operated on mains power 415v, 50hz +10%components are mounted on the panels are: capacitive load inbuilt inductive load inbuilt resistive load (external)salient features: three phase power light indicator for mains. front panel built with high class insulated bakelite sheet with sticker well printed circuits and symbols. mcb for short circuit protection connections are brought out through 4mm colored safety sockets. patch cords 4mm. the trainer is housed in metal cabinet. size of the trainer set 36 x 24 , power & power factor measurement by ct & pt in three phase circuittechnical specifications:power supplies: ac power supply 0-415v at 4a operated on mains power 415v, 50hz +10%digital meters: digital voltmeter digital ammeter , digital wattmeter (analog), digital power factor meter components are mounted on the panels are: 3 phase capacitive load (inbuilt) 3phase resistive load (external) 3phase inductive load (external) emergency stop
Tender For supply of digital capacitance meter (ce approved), as per specification attached. make: kusam-meco, b & k precision, metravi, htc only. note: to be supplied with nabl calibration certificate. [ warranty period: 12 months after the date of delivery ] ]