Web Analytics Made Easy - StatCounter

Nano Imprint Lithography System Tenders

Get complete information related to latest Nano Imprint Lithography System Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Nano Imprint Lithography System Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Nano Imprint Lithography System Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

corporations/Associations/Others

CTN :40933743 Due date: 16 Jul, 202516 Jul, 2025 NA
Tender For auction sale of electronic card st3000 part 5130397-502,transmitter, h250/rr/m9/esk ii,ultrasonic ft transducer t5-90-10-41,pulser f/pd meter,float mag lg 1inmocss316 acl13a160001001,ic programmed for apu (set l+h ),181221,radar-level transmt-asembly-saab-rtg40s0,electronic card ofradar gauge-saab-rtg40,electronic card radar rtg40s0cp1bp000t,electronic card radar lt 5401ah1i18spveb,illuminator for lev.gauge,level s/wultrasonic p/n 962.7da0-0c0-9m2,t/m,str14g,thl,gauge,pr,burdn,(-)1-1kg/cm2,dp gauge,0-1.75 kg/sqcm,6in,dp gauge capsule 0~400 mmwc,6in,1/2 npt,dp gauge capsule 0~600 mmwc,6in,1/2 npt,pg m/nbspg-v-15-s6-s-4-15ntm-0to6 -aesyi,pg m/nsfbspg-s15-s6-l-4-15ntm-0to60-aezg,pg m/nsfbspg-v15-s6-l-4-15ntm-0to60-aezn,gauge saver m/n gic/bourdon/gs/0-2.5kg,gauge saver m/n gic/bourdon/gs/1.6kg,gauge saver m/n gic/bourdon/gs/0-1.6kg,gauge saver m/n gic/bourden/gs/0-10 kg,gauge saver m/n gic/bourden/gs/0-16 kg,gauge saver m/n gic/bourden/gs/0-25 kg,gauge saver m/n gic/bourden/gs/0-4 kg,pg d m/n pgcsu-v-15-s6-xx-oto10-a-ez-gs,pg d m/npgcsu-s-15-s6-xx-oto16-a-ez-p6t,pg d m/npgcsu-v-15-s6-xx-oto16-a-ez-e-f

CTN :40906729 Due date: 03 Jul, 202503 Jul, 2025 2.00 Lacs
Tender For supply of hospital medicines - synthetic absorbable polygalactin 910/polyglycolic acid coated with polycaprolate size 2/0, 70-90 cms, 1/2 circle rb 30-40 mm, anatomical nasal pack, polyvinyl alcohol sponge 8 cm, nasal pack 10.0cm without airway, pvc tracheostomy tube, cuffed, double lumen with fenestration, size 7.5 mm, pu tracheostomy tube with cuff with double lumen with fenestration with swivel neck plate & decanullation plug 7.5 mm, pu tracheostomy tube with cuff with double lumen with fenestration with swivel neck plate & decanullation plug 8 mm, pu tracheostomy tube with cuff with double lumen with fenestration with swivel neck plate & decanullation plug 8.5 mm, pvc tracheostomy tube, cuffed, double lumen with fenestration, , size 8.0 mm, pvc tracheostomy tube, cuffed, double lumen with non fenestration, size 7.5 mm, pu tracheostomy tube with cuff with double lumen with fenestration with swivel neck plate & decanullation plug 7.0 mm, dextrose monohydrate for oral use in pack of 100 gm with or without vitamins and minerals, dextrose monohydrate powder pkt of 500 gm (for oral use) without vitamins, transducer hand piece (hp-054) for ultrasonically activated cutting and coagulating device compatible with ultrasonic harmonic scapel, dry view film 08 x 10 compatible with konica camera (pack of 125), dry view film 10 x 12compatible with konica camera (pack of 125), lina skin hook small, sharp, dual pack,prestrelised (contains 5 hook), homatropine hydrochloride soln 2%, inj pentazocine lactate 30 mg/ml, 1ml amp, pethedine 50mg, 1ml inj, tab.docosahexaenoic acid 1 gm

State Government

CTN :40841890 Due date: 18 Jul, 202518 Jul, 2025 NA
Tender For supply and installation of laboratory equipment experimental setup for fyimp ug practical classes at the department of physics, gauhati university - laboratory equipments/experiment set ups, experiment name: to verify the law of malus for plane polarised lighttechnical specifcations:i. light source: - led: 532 nm or 635 nm ( 2 nm stability), 1 5 mw adjustable output. - unpolarized (extinction ratio >500:1). - collimated beam (divergence 0.5 mrad); qty-1ii. polarizers- glan-thompson or polymer film. - extinction ratio 10 :1 @ operating wavelength.- mounted in 50 mm rotation holders.; qty-2iii. rotation stage- motorized analyzer rotation (0.05 resolution). - accuracy: 0.1 . - range: 0 360 (continuous).; qty-1iv. photodetector- silicon photodiode (400 1100 nm). - linearity: r 0.999 (0.1 w 5 mw).- digital readout: 0.1 w resolution.; qty-1v. optical bench-- anodized rail ( 60 cm) with kinematic mounts. - vibration-damping feet.; qty-1, experiment name: to determine thespecific rotation of sugar solution using polarimetertechnical requirementsa.core instrumenti. light source- - sodium d-line (589.3 nm) or tunable led ( 2 nm stability). - output stability: 0.2% drift/hour.ii. polarizer/analyzer- glan-thompson prisms or high-grade polymer film. - extinction ratio 10,000:1 at 589 nm.iii. rotation stage- motorized with 0.001 resolution.- accuracy: 0.005 .- range: -90 to +90 .iv. sample cell-- borosilicate glass tubes with precision ground ends. - path lengths: 0.5 dm, 1.0 dm, 2.0 dm ( 0.01 dm tolerance). - temperature-controlled jacket (5 50 c 0.1 c).v. detector- photomultiplier tube (pmt) or low-noise photodiode. - linearity: r 0.999 over 0.1 w 5 mw rangevi. enclosure- light-tight with vibration damping. - internal black anodized surfaces.b.measurement specificationsi. specific rotation: range: -180 to +180 resolution: 0.001 accuracy: 0.01 ii. concentration-range: 0.01 0.5 g/ml (sucrose in water) detection limit: 0.001 g/mliii. temperature control-stability: 0.1 c at 20 c (standard condition), experiment name: to determine the wavelength and velocity of ultrasonic waves in a liquid (kerosene oil, xylene, etc.) by studying the diffraction through ultrasonic gratinga.core componentsi. ultrasonic generator- - frequency range: 1 10 mhz ( 0.1% stability). - adjustable output: 0 50 w. - digital display (resolution: 0.01 mhz).ii. transducer- piezoelectric (pzt) crystal, resonant at 2 5 mhz. - liquid-coupled design for efficient energy transferiii. liquid cell- optical glass (low thermal expansion). - dimensions: 100 50 50 mm (l w h). - sealed with quartz windows.iv. light source- he-ne laser (632.8 nm, 2 mw) or sodium lamp (589.3 nm). - beam collimation: 0.5 mrad divergence.v. optical system- adjustable slit (10 500 m). - collimating lens (f = 150 mm, 50 mm). - precision rotation stage for detector (0.01 resolution).vi. detection system- photodiode/pmt detector with linear response (400 800 nm). - traveling microscope (0.01 mm resolution) or ccd camera ( 5 mp).b.measurement specificationsi.wavelength ( )range: 0.1 2 mm, resolution: 0.001 mm, accuracy: 1%ii. velocity (v)range: 800 2000 m/s (liquids) resolution: 1 m/s accuracy: 2%iii. diffraction angles- measurement range: 30 resolution: 0.01 , experiment name: to verify the stefans law of radiation and to determine stefan s constanta.core componentsi.black body radiator- cavity-type design (emissivity 0.99). - material: nickel-plated copper.- operating range: 50 c 600 c. - aperture diameter: 10 mm 0.1 mm.ii. heating system- pid-controlled furnace (0 600 c). - stability: 0.5 c at 300 c. - power: 500 w (ac 230v).iii. temperature sensor- type k thermocouple or pt100 rtd. - accuracy: 0.5 c at 500 c (nist-traceable).iv. radiation detector- thermopile sensor (spectral range: 0.3 20 m). - responsivity: 10 v/w.- active area: 10 10 mm .v optical path. - water-cooled collimating tube with baffles.- adjustable aperture to define solid angleb.measurement specificationsi. temperature range100 c 500 c (reso

CTN :40118974 Due date: 03 Jul, 202503 Jul, 2025 NA
Tender For corrigendum : supply of ultrasound rodent repellant system at bpcl mr - 60.01.29.001.5 - ultrasonic rodent repeller controller , 60.01.29.002.5 - rodent transducer range 500 sq. ft , - supervision for instal comm config , - amc of rodent repellant sys year 1 , - amc of rodent repellant sys year 2 , - amc of rodent repellant sys year 3

CTN :40729368 Due date: 07 Jul, 202507 Jul, 2025 NA
Tender For supply of contact ultrasonic transducer
 Loading, Please wait...

Connect us via What's Up