Get complete information related to latest Needle Valves Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Needle Valves Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Needle Valves Tenders.
Tender For supply of transformer oil sample 1litre bottle of ss304 as per is9434 & is10593 with 2nos needlevalves & 1m length pvc transparent pipe for transformer oil dga & bdv testing. [ warranty period: 30 months after the date of delivery ] ]
Tender For tender for supply of forged steel needlevalves alloy steel full thread stud bolt and valves - valve needle fs api lpt scr half inch x 5000 lb , bolt stud alloysteel f thd , bolt stud alloysteel f thd , valve gate api lpt 3 inch x 128 lbs api std 5b , 12 inch butterfly valve , 4 inch gate valve threaded
Tender For supply of multi process control trainer setup for instrumentation engineering lab under mhrd scheme - purchase of multiprocess control trainer setup for instrumentation engineering lab under mhrd scheme - multiprocess control trainer set up, multiprocess control trainer set up - specifications:- setup must contain flow, pressure, level, temperature loops also derived loops like cascade and feedforward loops. temperature loop must be independent. setups consist of a circulating closed loop water plant or circulating water system including control valve, tanks, independent pumps and necessary valves including bypass valves and rotameters. using this we can be able to do flow control loop with pid,level control loop with pid,and pressure control pid, as independent experiments.the setup must include the following:1.one linear characteristics diaphragm operated control valve with 15mm stroke 1/2-inch size, type: high-capacity globe seat leakage class (as per ansi/fci 70.2).2.measuring tank with volumetric measurement scale and 1000mm level, in of 25 ltr capacity. sump tank min of 40 ltr capacity. all tanks made of ss304, with sight glass, and finished with mat steel finish.3.2 no s smart dp transmitter for flow and level measurement with hart protocol, display and keys integrated for calibration,0-1000mmh2o measurement range,0.01% accuracy, international iso certified ce approved make,24v supply,4-20ma output, loop powered.4,1nos of magnetic flowmeter with display and keys integrated for calibration,0-2000lph measurement range, read out: 0 - 100%, 4-20ma lcd display,0.05% accuracy, international iso certified ce approved make,24v supply,4-20ma output to measure flow as a independent loop.5,. smart pressure transmitter and temperature transmitters with hart protocol, display and keys integrated for calibration, pressure transmitter 0-10bar measurement range, read out: 0 - 100%, 4-20ma lcd display,0.05% accuracy, temperature transmitter 0-250 rtd type international iso certified ce approved make,24v supply,4-20ma output, loop powered.6, pressure tank of 24 liters with necessary valves for pressure loop.7.1nos orifice plate (ss304) and assembly grade with flange 1/2-inch size for flow measurement.8.2 nos pumps 0.5hp, ss centrifugal pump, minimum 1-inch pipeline of ss or high-pressure withstanding plastic with plastic welding.9. rotameters 2nos 1 inch size flow: 200-2000 l/h,ss thread, clear acrylic type.10, plc control station with 4 analogue inputs and one analogue output with necessary digital inputs and outputs to operate all loops directly from panel side.plc must have ethernet connectivity with supported protocols profinet and modbus tcpip.11.required all pneumatic components to full fill the process loops such as fr,needlevalves etc.12,i to p converter 4-20ma to 3-15psi with 1/4" process connection with proper copper copper tubing.13, loop including flow pid control, level pid control, pressure pid control, cascade control (level flow), ratio control (flow flow).14.all loops can be operated using a scada system and independent pushbutton control includes trend of all analogue signals and pid tuning. scada direct profinet connectivity to plc and computer with intel i5 processor, 8gb ddr3 ram,1tb sata hdd,licenced windows 11 professional.15, required a standalone software application that must be installed on pc in which it can used to control and monitor all the functions used in scada. the application must contain process parameter trend graph plot for to study about process loops.16.the whole system setup must be in ms powder coated standalone mobile table with lockable castor wheels. all the components used be industrial. copper tubing for air connection, pressure gauges 4inches 3nos, electrical wiring connection to be flexible for to connect field devices. panel with switches, indicator, test points with banana connectors as required, multistrand wire with proper insulated lugs, ferruling & neat wire dressing & clam
Tender For rate contract for two years (extendable) for purchase of m and e items for use in gas mani fold- bpc flow meter with humidifier bottle:, providing of bpc flow meter (polycarbon 0-15 ltr. capacity/min) and 250 ml humidifier bottle with bs type oxygen probe for existing outlets complete etc. as required at site., humidifier bottle:, humidifier bottle should be compatible with oxygen flow meter and it should be reusable type. the bottle should be shatter proof and made of polypropylene. metal component of humidifier bottle should make of brass with anti- corrosion nickel plating., trolley for b type cylinder:, trolley with load capacity of one oxygen b type cylinder. made up of mild steel & frame work made of crc tube. surface finishing should be powder coated. trolley with 02 no. of wheels., nrv for manifold:, providing & fixing of manifold non return valve is specially made of solid brass body, 100% flow return guard. facilitates changing of empty cylinders plus helps in preventing the back flow of the gases. high pressure non- return valve - 230 bar (3330 psi), 2nd fix for ohio/heal rom type oxygen/air/nitrous/vacuum outlet:, a gas specific back body with steel mounting plate. compatible for existing outlet., probe for ohio/heal rom type oxygen/air/nitrous/vacuum outlet:, probe made with stainless steel matching with existing outlet point. indigenous and ce certified., probe for pb type oxygen/n2o/vacuum/air outlet:, probe made with stainless steel matching with existing outlet point. indigenous and ce certified., star for 2nd fix of pb type oxygen/n2o/vacuum/air outlet, spring for 2 fix of pb type oxygen/n2o/vacuum/air outlet, nrv for ohio/heal rom type oxygen/air/nitrous/vacuum outlet point:, providing & fixing of non return valve is specially made of solid brass body, 100% flow return guard., o' ring set for penlon/ beconmedas type oxygen/air/nitrous/vacuum outlet point, ward vacuum unit with 2000ml jar & regulator:, consists of one no. vacuum regulator with on/off knob, collection jar of capacity 2000 ml made of unbreakable which is polycarbonate/plastic auto clavable up to 134 deg. c. a bracket is also provided regulation range from 0-760mm hg. the vacuum unit should include regulator along with 0-760mm of hg vacuum gauge of 2" size dial. 2000ml capacity reusable plastic collection bottle with overflow safety trap with plastic slide wall mounted type., ward vacuum unit with 600ml jar & regulator:, consists of one no. vacuum regulator with on/off knob, collection jar of capacity 600 ml made of unbreakable which is polycarbonate/plastic autoclavable up to 134 deg. c. a bracket is also provided regulation range from 0-760mm hg. the vacuum unit should include regulator along with 0-760mm of hg vacuum gauge of 2" size dial. 600ml capacity reusable plastic collection bottle with overflow safety trap with plastic slide wall mounted type., vacuum regulator:, the vacuum regulator with on/off knob along with range from 0-760mm hg &vacuum gauge of 2" size dial., gasket for 600 ml. of ward vacuum unit, gasket for 2000 ml. of ward vacuum unit, mounting bracket for ward vacuum unit (plastic):, a bracket is also provided regulation range from 0-760mm hg., ohio hill rom outlet sheet, ohio/ hill rom outlet o'ring set, pb type outlet sheet, pressure gauge(o₂/n₂o/air):, providing & fixing of pressure gauge (pressure range- 100 to 400 kg/cm2) material- stainless steel body, size- 4 inch & pressure (0 bar to 7 bar), high pressure tube(hard type):, non toxic. medical grade pvc material finish. transparent high pressure tube options are clear in contraction as well as smooth in usage., low pressure tubing:, non toxic, medical grade pvc material finish. transparent low pressure tube options are clear in contraction as well as smooth in usage., lock for ohio/hill rom outlet point, nrv washer for ohio/ hill rom outlet point
Tender For corrigendum : supply of ibr-approved levcon make reflex level gauge, model no. rs458-1118, details as per attached annexure-i , spares offset valve for reflex level gauge model no. rs458-1118, details as per attached annexure-i , needlevalves with hand- wheel operation. details as per attached annexure-i
Tender For supply of transformer oil sampling bottle made of stainless steel gr.304 for testing /analysis as per is: 9434/1992 & is: 10593 having gas tight needlevalves and hose nipples at both ends. capacity : 1000 ml. required to collect transformer oil samples for dga testing. ]
Tender For corrigendum : supply of various sizes of angle needlevalves, swing check valves, globe valves and gate valves required for cooling water system, oil supply system and compressed supply system at slbhes, srisailam dam west, nagarkurnool (dist) - 509326, telangana.