Tender For supply of 55 inches video wall panel display unit with push bracket wall mount , surveillance system to distribute across 4 video display control unit , customised wooden fabrication work , centralisation horizontal double mounting siren 5 km , centralisation horizontal double mounting siren operates from 2 location switch control unit with armoured cable 4 core 3 sq mm 3 phase line power cabling piping and installation , poe gigabyte switch with 2 sfp modular , dual location displayunit operating system with wire mouse , installation of networking system configuration network cablling as per power cabling total entire setup
Tender For request for quotes [rfq 018/2026-27] for carrying out structured lan cabling work at recovery vertical, 4th floor lic ho annex building and part of inspection wing, 4th floor, spencer towers ho annex building (renovation work) & network rack dressing at 4th floor main network room and 1st and mezzanine floors network racks at ho main building
Tender For shifting and installation charges for msedcl network equipment s and installation of new rack with cabling at lic building gulestan, fort mumbai.
Tender For bid to ras supply of 8mp network ir bullet camera 30 mtr , full hd network ir ptz camera , 32ch 4k ai network video recorder with 4 tb storage , 4 port poe switch 10 100 1000 , 16 port manageable poe switch , display panel 43 inch , ote , cat 6 cable 305 mtr , rj 45 connector 100 nos , power strip 4 port , 4 mm 2 core power cable , 6 u rack , enclosure box , ofc patch cord , poe outdoor box , 6 core ofc cable , ofc binding wire , gi wire , poe injector , pvc junction box , ptz wall mounted braket 4 ft , 5 kva online ups with 1 hr backup , 3 kva online ups , camera and pole installation and configaration and ofc laying and structure cabling and misc works
Tender For tender for supply of radiation resistant cctv camera : : - type-ii (color ccd/cmos , 100m rad) radiation resistant camera head along with radiation resistant pan & tilt unit and mounting brackets. as per attached annexure-1 , corrigendum annexure-2 and annexure-3. , cabling system to transmit signals form vault cameras to ccu system which includes camera to ccu radiation resistant composite cable of 300 meters with 6 sets of cable connectors and applicable power cables as per annexure-1 , corrigendum annexure-2 and annexure-3. , field camera control unit and its racking system which includes 2 no. of camera control unit sub rack & 6 sets of camera control unit (ccu) cards (3 to be installed in field and 3 to be kept as spare for future ) as per annexure-1 , corrigendum annexure-2 and annexure-3 or equivalent sub rack system as per annexure-1 , corrigendum annexure-2 and annexure-3. , setup to convert ccu signals to optical signals which should include 3 no. of fiber optic transmitter and receiver set (capable of 4 camera system) and 6 no. of fiber patch cords , single mode , simpex and 3 no. of light interface unit 12 port , as per annexure-1 , corrigendum annexure-2 and annexure-3. , type-vi (color ccd/cmos sensor , non rr auto dome camera) with mounting brackets as per annexure-1 , corrigendum annexure-2 and annexure-3. , mechanism to transmit signal from non radiation resistant camera including , poe power supply for non-rr ptz camera (6 no.) field jb /rack in ss material for non-rr ptz camera (2 no.) liu 6 port , din rail mountable for non radiation resistant ptz camera (3 no.) din rail 8 port un-managed network switches (3 no.). 4 no. of fiber patch cords , single mode , duplex for non-radiation resistant ptz camera or equivalent as per annexure-1 , corrigendum annexure-2 and annexure-3. , mechanism for receiving signal at control room including light interface unit 24 port , rack mount (2 no.) and network video encoder (minimum 16-channel) along with accessories for intra-panel connections (2 no.) and 24 port un-managed network switches or equivalent (2 no.) , 4 no. of fiber patch cords , single mode , duplex as per annexure-1 , corrigendum annexure-2 and annexure-3. , recording and monitoring pc as per annexure-1 , corrigendum annexure-2 and annexure-3. , joystick suitable for mounting on control room panel cutout as per panel drawing as per annexure-1 , corrigendum annexure-2 and annexure-3. , 21 inch led backlit led color monitor as per annexure-1 , corrigendum annexure-2 and annexure-3. , video monitoring software setup as per annexure-1 , corrigendum annexure-2 and annexure-3 for minimum 9 camera. , mobile dolly consisting of camera control unit (ccu) , encoder , switch , joystick , engineering laptop with 15-inch to 17-inch screen , video management software for one camera , connection cables etc and their cabling as per annexure-1 , corrigendum annexure-2 and annexure-3. , control panel/rack 42u/ 27u setup for racking all instruments of cctv at control room as per annexure-1 , corrigendum annexure-2 and annexure-3. , cabling network optical fiber cable (6 core armored cable)-2000 meters twisted pair cable , rs485 , signal cable -200 meters unarmored coaxial cable rg59 -200 meters ethernet cable , cat-6 utp cable -610 meters video connector set -10 meters ethernet connectors rj-45 100 pieces conduit for cables 800 meters and other separate cables/ power cables/accessories required during installation one set of tool tackles for assembly/ disassembly/ of radiation resistant camera head viz. allen keys , lubricants , cable ties , loctite , heat sink , blank caps etc. 2 no. of control panel/rack size 27u setup for racking all instruments of cctv at field as per annexure-1 , corrigendum annexure-2 and annexure-3. as per annexure-1 , corrigendum annexure-2 and annexure-3 . , site installation & commissioning as per annexure-1 , corrigendum annexure-2 and annexure-3. , spare radiation resistance camera head s
Tender For rfq 015/2026-27 dated 05/06/2026 for carrying out structured lan cabling work at general administration vertical, dwarakanath bhavan, 3rd floor & rack dressing at 2nd floor of all network racks at basavanagudi ho annex
Tender For providing of custom bid for services - ---- request for proposal (rfp) / terms of reference (tor) intelligent laboratory networkmanagementsystem (ilnms)
Tender For corrigendum : provn of 200 kva transformer for tcp-5 area, external electric network near 66 kv sub station and conversation of ht oh electric line to ug cabling at map-i area at faridkot mil stn
Tender For corrigendum : selection of agency for providing networkmanagementsystem (nms) and help desk solution (hds) for monitoring extended connectivity nodes under goa broadband network (gbbn)