Get complete information related to latest Nitrogen Dispenser Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Nitrogen Dispenser Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Nitrogen Dispenser Tenders.
Tender For providing of customized amc/cmc for pre-owned products - scope of work is as per the attached document; athena nitrogen generator; comprehensive maintenance contract (cmc); scope of work is as per the attached document; no
Tender For tender for the supply of various equipments - muffle furnace, "al2o3 sample plate, al2o3 furnace door block, protection glove, crucible clip, crucibles, karl fischer titrator, "titration vessel, detector electrode with lead, generator electrode (with frit) with lead, desiccant tube and cap, injection septa (pack of 10), gas tight syringe 1.0ml , luer needle 17-gauge, dust cover, results manager software, main power pack, fuse, karl fischer titration reagent(s), nist calibration standard, refrigerated centrifuge (bench top), bottles/falcon tubes/adapters for 0.2ml tubes, one set of other items (adapters) required for improving the applicability/system performance should to be quoted, nitrogen evaporator, evaporation tubes, gas fuse , water purification system including water softner, cartridges, filters etc. for , bomb calorimeter, "ignition wire, cotton thread, combustion crucible, bomb, nist certified benzoic for calibration, any other accessories required for analysis of food samples., gas chromatograph with ecd, tcd, fid with autosampler, "pesticide column (30 m x 0.250mm x 0.25m (5ms (95% dimethyl-, 5% diphenyl-polysiloxane / 1ms (100% dimethyl polysiloxane or equivalent) 100 mm column for fatty acid profiling with main concern of trans fatty acid application, column for cholesterol application, stationary phase: 95% dimethyl-, 5% diphenyl-polysiloxane (30 m x 0.250mm x 0.25m),, "vial sets (1, 2 ml, crimp type, amber and clear glass), vials (10, 20ml crimp type with cap & septa), 300/500 l recovery vials, septa ptfe/silicone (for 1, 2 ml vials), septa ptfe/silicone (for 10, 20 ml headspace vials), ergonomic crimping tools for different vial types, ergonomic decapping tools for different vial types, head space vials 10,20 ml capacity, suitable syringes for quoted autosampler, suitable headspace syringe /valve/loop, quechers kits for pesticides and herbicides in following matrices:, matrices with high fat, matrices with high water content, matrices with high pigmented, spe cartridges for water., ultra performance liquid chromatography (uplc) with photodiode array (pda), fluorescence (fld) and refractive index detector (rid), sample vials with 1.5 ml or greater, stainless steel ultra sonic bath with the capacity of 5 l or more, with time setting (min) 1-30min or continuous operation with led and push button (should be ip 33 protection class) for sonication of spare parts as well as solvents, fittings, frits, ferules and tubings, tubing cutter, solvent bottles (1000 ml capacity), solvent filters (glass & ss both, compatible manual syringes -10 l, 20 l, 50 l, standards for hplc calibration for pda, ri and fluorescence detector, consumables required for each detector must be provided., "hplc columns: one each of, c8 = 250 4.6 5m c18 = 250 4.6 5m, cyano = 250 4.6 5m. amino = 250 4.6 5m, phenyl = 250 4.6 5m. silica = 250 4.6 5m., all columns must be supplied with respective guard column and holder. ", uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate., uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate., ft-ir with atr & liquid cell, " hydraulic press with kbr die and pellet holder, suitable mortar pestle (dia 5-6 cm), suitable portable de humidifier to maintain 30- 60% rh, temperature and relative humidity digital indicator with calibration certificate from iso 17025 accredited lab., reference nist standard polystyrene film (0.3 mm) over the range of 3800 cm-1 to 650 cm-1., abbes refractometer,
Tender For supply of calibration of deep freezer , calibration of muffle furnace , calibration of hot air oven , calibration of centrifuge , calibration of sonicator , calibration of analytical weighing balance , calibration of vortex mixer , calibration of water bath , calibration of pipettes , calibration of beaker 50 ml , calibration of beaker 100 ml , calibration of beaker 250 ml , calibration of beaker 500 ml , calibration of beaker 1000 ml , calibration of volumetric flask 25 ml , calibration of volumetric flask 50 ml , calibration of volumetric flask 100 ml , calibration of volumetric flask 250 ml , calibration of volumetric flask 500 ml , calibration of volumetric flask 1000 ml , calibration of measuring cylinders 25 ml , calibration of measuring cylinders 50 ml , calibration of measuring cylinders 100 ml , calibration of measuring cylinders 250 ml , calibration of measuring cylinders 500 ml , calibration of measuring cylinders 1000 ml , calibration of conical flask 25 ml , calibration of conical flask 50 ml , calibration of conical flask 100 ml , calibration of conical flask 250 ml , calibration of conical flask 500 ml , calibration of conical flask 1000 ml , calibration of thermocouple , calibration of hygrometer , calibration of digital thermometer , calibration of tacometer , calibration of ph meter , calibration of sieve no 1 mm , calibration of sieve no 1.70 mm , calibration of sieve no 4.75 mm , calibration of nitrogen generator , calibration of nitrogen evaporator
Tender For auction sale of rolling stock - condemned bg 8 wheeler accident involved lhb power car ( luggage brake cum generator car) with all available ferrous-non ferrous-wooden fittings thereon excluding rc items . mechanical rc items: 1) complete fiat bogie arrangement complete set, 2) wheel set complete with axle and roller bearing assembly complete set, 3) centre buffer coupler complete set, 4) main door, 5) lavatory door, 6)ic door. electrical rc items: 1) rmpu unit complete set, 2) 60kva transformer, 3) rebc cum rbc, 4) d&ed (disconnecting and earthing device), 5) contactors, 6) microprocessor and display, 7) smoke detection and sensor.coach number- 1) ec lwlrrm 181371 c = 1 coach, ds8 no: 023280-25-11875 dt 24.10.2025 (232820 dt 24.10.2025) , pl.no. 98111061, location: near kavarapettai railway station, custodian: sse/c&w/tnpm, note: 1) at the time of delivery all items including zero value items such as rexene, rubber, frp etc., should be removed and cleared by the purchaser from railway premises and should be disposed as per the existing norms of central/state government.d and cleared by the purchaser from railway premises and should be disposed as per the existing norms of central/state government. 2) bio toilet to be defaced before delivery. 3)rate per number should be quoted,4)coaches are accident involved and grounded/trapped/upside down condition .5) all rc items which are in cut/damaged condition are not saleable and should be handed over to custodian only. 6) nitrogen cylinders, water cylinders, fire extinguishers available in the coach are not saleable and should be handed over back to custodian. 7) rc items to be handed over to the custodian at specified location (8) cutting permitted to loadable size only. (9) crane loading permitted. (10) purchaser should take safety precaution while cutting of coach.(11) one fuel tank available in power car and another is available between the main tracks which is away from power car, both are saleable. (12) the purchaser may be permitted to remove the saleable items from the power car without disturbing the brake van, which is very close to the power car due to the accident.