Tender For repair / maint of split acs 2/1.5 ton , windows acs 2 / 1.5 ton , voltage stablizers and connected items installed at command hospital (wc) and other various location in aor of age e/m ch - servicing of split type ac of capacity 2/ 1.5 tr after disconnecting all incoming and outgoing electric connection, water drain pipe line connection etc. and wash with approved chemical mixed water with the pressure pump, after servicing cleaned all the disturbed area and reassembling the water/electric connection and testing for entire satisfaction of engr-in-charge., all as per item no. 1 here-in-above but window type ac 2/1.5 tr capacity., supplying and charging of refrigerant gas r-22 only after vacuuming dehydration, leak testing of the system as per standard practice testing for proper cooling effects and satisfactory performance complete all as specified and as directed by engr-in-charge for room split/window type ac of capacity 2/1.5 tr., all as per item no: 3 above but gas r-32, all as per item no: 3 above but gas r-410a., all as per item no: 3 above but gas r-134a., taking out defective capacitor of capacity 50+6 mfd after disconnecting all incoming and outgoing electric connection including supply & fix new capacitor on same place and testing complete all as specified and as directed by engr-in-charge, all as per item no:7 here in above but of capacity 45+4 mfd ., all as per item no:7 here in above but of capacity 45 mfd ., all as per item no: 7 here in above but of capacity 6 mfd ., all as per item no: 7 here in above but of capacity 4 mfd ., supply & fixing as in replacement copper pipe 1/2" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 1/4" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 5/8" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 3/8" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply and fixing of insulation foam for copper pipe of size 1/2" after removing old one., supply and fixing of insulation foam for copper pipe of size 1/4" after removing old one., supply and fixing of insulation foam for copper pipe of size 5/8" after removing old one., supply and fixing of insulation foam for copper pipe of size 3/8" after removing old one., supply and fixing as in replacement of pvc flexible pipe 15 mm dia including any fittings as required complete inclusive of any type of leakage testing., all as per item no: 20 above but pipe of 20 mm dia., supply and fixing as in replacement of pvc water drain pipe 25 mm dia complete inclusive all fittings and any type of leakage testing., material and labour for sub main wiring with 2 x 2.5 sqmm +1 x 2.5 sqmm single core flame retardant pvc insulated unsheathed cable with stranded copper conductor drawn in and including heavy grade frlsh pvc concealed conduit isi marked with all accessories on walls and making good the disturbed surfaces including all conduits fittings, clamps guittes etc for earth dbs and boxes with proper thimbles all as directed by engr-in-charge. note :02 run of 2.5 sqmm , 01 run of 2.5 sqmm cable and 01 run of conduit shall be measured as one unit and paid accordingly., all as per item no: 23 here in above but of size 2x 4 sqmm +1x 4 sqmm., m&l cutting chases, pinning in stone concrete block or slab walls & making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring ,etc., and making good, cutting exc. 10 cm girth., supply and fix as in replacement of rigid non-metallic pvc conduit of size 20
Tender For supply of general printing item in kandi s.d hospital - forms single side , forms single side , bi-color , er-ticket , er-ticket (both side) , register , register , register , visiting card , froms , forms single side , bi-color , blood bank , cross match , forms , usg/diet , requisition forms , board (both side) , attendance , register , usg/diet , requisition forms , best quality paper , sncu slip , other forms + board printing , forms single side , forms single side , bi-color , stamp (small size)
Tender For corrigendum : procurement of medical consumables items for use by the cardiology department, goa medical college, bambolim - injectable cardiovascular ultrasound contrast agent comprised of lipid-coated echogenic microbubbles filled with octafluoropropane gas or equivalent approved agent (cost comparison will be based on per study cost); in remarks - please detail the dose required per study per the instructions for use, disposable electrodes designed specifically for patient monitoring, disposible electrodes designed specifically for stress testing - please quote only those that are specifically designed for stress testing, disposible electrodes designed specifically for holter monitoring - please quote only those that are specifically designed for holter monitoring, disposable defibrillator patches (anterior and posterior) for use with philips brand defibrillators, disposable radiolucent defibrillator patches (anterior and posterior) for use with philips defibrillators, printer paper roll for philips mrx defibrillator and for efficia defibrillators, thermal printing paper for sony thermal printer used with echocardiography machines (model up/d-897), ultrasound jelly for echocardiography 5 litre pack, ecg thermal printing paper for use with philips pagewriter tc20 ecg machine; philips make only, ecg thermal printing paper for use with ge mac 5500 hd ecg/stress testing machine; ge make only, ecg thermal printing paper for use with bpl cardiart 6208 view plus ecg machine; 80 mm width roll, filter for hamilton ventilator hma anti-bacterial filter, flow sensor for hamilton g5 ventilator, oxygen cell for hamilton g5 ventilators, oxygen sensor medtronic pb840 ventilators, oxygen sensor medtronic pb840 ventilators, oxygen sensor medtronic pb840 ventilators, abg machine sensor cassette for radiometer abl 9 machine - 200 tests with 60 days validity with ph, pco2, po2, hct, na, k, ca++, chloride, lactate, abg machine ssolution pack for radiometer abl 9 machine (sp9), ventilator circuits (two limb) for adult patients, non-invasiveventilator face mask, nasal prongs for pediatric patients, normal saline 1 l pouch pack suitable for use with pressure infusor bag, normal saline 0.5 l pouch pack suitable for use with pressure infusor bag, pressure bag with manometer for iv infusion/pressure infusor bag, silk suture sterilized and packed with cutting needle 1.0 silk nw 5062 or equivalent, silk suture sterilized and packed with round body needle 1.0 silk nw 5063 or equivalent, surgical skin stapler with stapler cartridge for pacemaker pocket closure, staple remover, surgical disposible scalpel blade only number 11, surgical disposible scalpel blade only number 15, iodine impregnated antimicrobial transparent incise drape 23 x 23 cm, film transparent dressing with non-adherent pad 3 1/2 inches x 6 inches (9 x 15 cm), packing material for cath lab use 5 cm width x 200 metres roll, packing material for cath lab use 7.5 cm width x 200 metres roll, packing material for cath lab use 10 cm width x 200 metres roll, packing material for cath lab use 15 cm width x 200 metres roll, packing material for cath lab use 20 cm width x 200 metres roll, packing material for cath lab use 25 cm width x 200 metres roll, packing material for cath lab use 30 cm width x 200 metres roll, ethylene oxide (eto) gas cartridge, labelling instrument for packed items for cath lab, printer ribbon for use in labelling instrument l-1 will be calculated for labelling instrument with label rolls (total quantities), label roll for use with instrument quoted for in labelling instrument with built in eto exposure indicator, label roll for use with instrument quoted for in labelling instrument with built in steam exposure indicator, biological indicator for use in eto sterilizer, biological indicator for use with autoclave sterilizer, incubator for use with biological indicators quoted above l-1 will be calculated for incubator with total quantities of biological indicators in above t
Tender For various electric and other item tender zenana hospital jaipur-suction trolley with probe, regulator, and 2000 ml jar (including installation); suction tube (including installation); 1.5 hp submersible motor with starter (including installation); screwdriver; 12-inch adjustable wrench; dg set locking latch; allen key set; electrical safety shoes; rmu panel cover (including installation); ht testing of oxygen cylinders; replacement of damaged wooden planks (9x9x6 mm) with iron covers on the oxygen cylinder unloading platform (including installation); 6-inch iron pipe (20 feet); suction jar probe; 15 hp submersible motor pump (including installation); 4-inch borewell iron pipe (20 feet, including fixing); l&t submersible pump starter (20-32 ampere).
Tender For laying of 600 mm dia np3 pipeline from mahatma jyotirao phule praja bhavan to vivekananda hospital in 97-somajiguda, circle-17,kz,ghmc (item no.07)
Tender For single source procurement for x-ray films (proprietary item) used in carestream system at ruhs hospital, jaipur -carestream dry laser digital x-ray films, make-konica minolta (size 8"x10" & 10"x12")