Web Analytics Made Easy - StatCounter

Non Linear Junction Detector Tenders

Get complete information related to latest Non Linear Junction Detector Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Non Linear Junction Detector Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Non Linear Junction Detector Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :41795023 Due date: 26 Sep, 202526 Sep, 2025 4.26 Crore
Tender For supply of bomb suit , real time view system , explosive vapour detector , electronic stethoscope , deep search metal detector , non magnetic tool kit , car remote opening tool kit , non linear junction detector , bomb suppression blanket

CTN :41503207 Due date: 17 Sep, 202517 Sep, 2025 NA
Tender For corrigendum : tender for supply of measure instruments ultrasonic flow meters : : - type 20008m limit switch , temperature sensor assembly(without electronic module)lm 196 , elastic guard ring , connector (plug - coupling) , stepseal seal k diam.14x21.7 turcite t10 , anti-extrusion ringdia 150 , pressure transmitter 0-4 bar absolute g1-4 female , pressure transmitter 0-15 bar absolute g1/4 female , dn80 fresch water sensor , supplier , dn40 sea water sensor , glydring sealdia 40 , thermal flow sensor ta10 , flowrate detector-cooling circuit-shaft stern gland nd20

Central Government/Public Sector

CTN :40582377 Due date: 13 Sep, 202513 Sep, 2025 NA
Tender For bid to ras corrigendum : supply of non linear junction detector as per (mha) qrs (q3)

CTN :39176258 Due date: 10 Sep, 202510 Sep, 2025 NA
Tender For bid to ras corrigendum : supply of explosive vapour detector , non linear junction detector , fiber optic survellance device

State Government

CTN :41413660 Due date: 15 Sep, 202515 Sep, 2025 NA
Tender For corrigendum : supply of non linear junction detector as per (mha) qrs (q3)

CTN :41731707 Due date: 16 Sep, 202516 Sep, 2025 NA
Tender For tender for supply of cems analyser sox nox and co2 spares adage : : - cems sample gas pump 360lph , 230vac , cems solenoid valve 3/2 way , 1/4 bsp-f , gas analyzer , type-sox nox analyser , spare , cems auto condensate drain pump 0.3lpm , cems flow meter 10-100lph , 1/4 npt -f , cems flow meter 50-500lph 1/4 npt -f , gas analyzer , type-sox nox analyser , spare , cems sp180-h , gas sample probe assembly , cems transformer , 230vac , cems sample gas cooler with indicator , cems gasket for sample probe sp190h , cems sp180h probe cartridge heater asly , gas analyzer , type-sox nox analyser , spare , detector , no , chnl 1 part no. 28602046 , detector , so2 , chnl 2 part no. 28602105 , detector , co2 part no. 28602051 , flowmeter part no. 28602024

CTN :41508258 Due date: 17 Sep, 202517 Sep, 2025 NA
Tender For corrigendum : supply of chemistry lab equipment - procurement of chemistry lab equipment, uv visible spectrophotometer equipped with integrating sphereapplicable for both solid and liquid sample, powder sample kit, diffuse reflectance standards of 2%, 5%, 10%, 20%, 50%, 100%, neutral density filter to obtain linearity for transmittance, and pc control(configuration: insight software for instrument along with core i7 processor and 512gb ssd), electronic balancestainless steel weighing plate, measuring range resolution: 0.001 g, weighing capacity measuring range 120 g, parameter 0.001 g readability (1 mg), capacity 120 g, outside size 20.5 cm (8 in.) 35 cm (13.75 in.) 9 cm (3.5 in.) weighing pan diam. 115 mm (4.5 in.), ph meterrecorder output 0 to 10 mv/ph, 0 to 10 mv/100mv (adjustable), ph range 0-14 phph resolution 0. 01, ph temperature compensation 0 - 100 c, mv accuracy 1 mv, magnetic stirrercapacity 1 litre,stirring paddle q-19 9 x 25 mm,dimensions 150 x 220 x 150 mm, with hotplate, capacity 5 litres, double distillation unit1.5 lph, material borosilicate glass with double stage distillation setup, pyrogen free dimension 650 x 630 x 520mm, flame photometergeneral range ppm, serum range meq,i,urine range meq,i,resolution 0.1 ppm / 0.1 meq,curve at accuracy 2% of fsdisplay 128 x 64 graphical lcd average time in-built in software,flame system lpg & dry oil free air,detector photodiode,aspiration time 3 ml per minute,gas control adjustable with knob,flame failure auto detection,gas cut off automatic,ignition system auto ignition,automiseraxial flow type,dimensions instrument: 365 x 245 x 220 mm approx. (lxbxh),pc interface usb power supply 230 v ac 10%, 50 hz, chromatography chambersize 26x13x26 height 26inch material teak wood, potentiometerrange: 0 to 199.9 mvresolution: 0.1 mvrepeatability: 1mvaccuracy: 1 mv 1 digit input impedance :> 1010 ohms operating temperature : 10 c to 50 c display : 3.5 digit bright red seven segment led display with auto polarity indication power : 230 10% ac ,50hz dimensions : 76*275*170 mm (approx.) weight : 2 kg. (approx.) standard accessories glass electrode : 01 no. reference electrode : 01 no. silver electrode : 01 no. platinum electrode : 01 no. dust cover : 01 no. electrode stand & clamp : 01 no. instruction manual : 01 no., polarimetrytouch screen, no warmup time required when instrument turned on, measuring multiple scales, conductivity meterresolution 0.1 ppm voltage 220 v,ec resolution 0.1 temperature range 0-100 c probe conductivity cell weight 1.5 kg auto cell constant measurement manually cell constant =1k dimension 32/23/18cm display type 3 1/2 digit seven segment led display measurable conductivity range in ppm number of ranges 5 power 230-volt main type of temperature compensation manual no. of calibration points 1 temperature compensation auto cond. range 0-1000 m in 5 range 200m*,2m,20m,200m,1000m phase single phase usage laboratory frequency 50 hz power source electric, handy ph, tds, and conductivity meterph range (-) 2.00 to 16.00,ph accuracy 1%,ph resolution 0.01 ph, orp range 1000 mv,orp accuracy 1%,orp resolution 1 mv,conductivity range,0 to 100 ms/cm,conductivity accuracy 2%,conductivity resolution 1 s,tds accuracy 2%,tds resolution 1 ppm,salt range 0 to 50 ppt,salt accuracy 2%,salt resolution 1 ppm,temp range 0 to 100 deg c,temp accuracy 0.2,temp resolution 0.1 deg c,atc yes,power aaa (1.5v) x 4 batteries, printerconnectivity technology usb, networkprinting technology laser special feature automatic document feeder, fast printing, scanner, copier colour blackmodel name laserjet pro mfp m128fnprinter output monochromemax print speed monochrome 20item weight 11100 gramsprinter media size maximum a4, b5, a6, dl, envelope, ups3kva online ups with 1 year batteries warranty

State Government

CTN :41711852 Due date: 19 Sep, 202519 Sep, 2025 NA
Tender For supply of non linear junction detector as per (mha) qrs (q3)

CTN :41678837 Due date: 12 Sep, 202512 Sep, 2025 26.00 Lacs
Tender For non linear junction detector nljd 02

CTN :41633078 Due date: 30 Oct, 202530 Oct, 2025 NA
Tender For procurement of spares for il-76 aircraft - relay box, seat back rh, cyl attachment bracket, deflector outer wing (lh), ramp cylinder, chanel unit, cylindr side door, dme (sd-67m), encoder, shock mount dme i, eletrical driven centrifugal pump, valve, mobile rig for hyd system optimisation, shutter, block, flexible wave guide kp-2, wave guide kp2, transreceiver r-832m, v/uhf trans receiver r-832m, invertor change over unit, power unit (6em-8), block, measure unit, switch-pressure(v), flow detcector, sensor flex detector, ppi,hr scope and rackkp2-4a-7, device, crane cock, ammeter, oxygen regulator
 Loading, Please wait...

Connect us via What's Up