Get complete information related to latest Non Medicinal Item Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Non Medicinal Item Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Non Medicinal Item Tenders.
Tender For supply of refrigerator double door 400 ltr , ilr small with voltage stabilizer , deep freezer small with voltage stabilizer , cold boxes small , cold boxes large , vaccine carriers with 4 icepacks , digital thermometer , ice pack , adult weighing scale , baby weighing scale , height measuring scale stadiometer , laryngoscope and endotracheal intubation tubes neonatal , mucus extractor , feeding tubes for baby , sponge holding forceps , vulsellum uterine forceps , tenaculum uterine forceps , torch without batteries , bowl for antiseptic solution , ent head light for opd , ear specula , digital b.p. apparatus , stethoscope , nsv set , minilap kits , nebuliser , otoscope , delivery table with mattress , disposable normal delivery kit , iucd insertion kit , suction machine electric , suction machine foot operated , oxygen cylinder accessories , hemoglobin meter , haemoglobin strips , autoclave hp 2 drum , cusco vaginal speculum s, m, l 1 each , sims vaginal speculum single nd double ended each of small, medium and large size , anterior vaginal wall retractor , kidney tray , cheatles forceps , reagents of cyan meth haemoglobin method for hb estimation , uristix for urine albumin and sugar analysis , abo nd rh antibodies , koh solution for whiff test , grams lodine solution 125 ml , crystal violet stain , acetone ethanol decolourising solution , safranin stain solution 125 ml , ph test strips , rpr test kits for syphilis , h2s strip test kits for fecal contamination of drinking water , test kits for estimation of residual chlorine in drinking water using orthotoludine reagent , whole blood finger prick hiv rapid test and sti screening test each , colorimetre , test tubes , pipettes , glass rods , glass slides , cover slips , scissors all types , binocular microscope , thermometer clinical , hub cutter , two bucket system for liquid waste management , simple operation table ot table , instrument trolley , i v stand , shawdoless 0.t.light , kellys pad for labour and ot table , radiant infant warmer , phototherapy unit , tube, feeding, ch07, l40cm, ster, soft, non toxic pvc tube suitable for neonates and children , oxygen catheter 8 f, oxygen cylinder , examination table with foot step , wheel chair , stretcher trolley , bed side screen , bed side locker , semi fowler bed with mattress , drum with tap for storing water , bed sheets , pillows with covers , blankets , baby blankets , towels , 3 colour been set for waste management , coloured puncture proof bags , o.t. fogger machine fumigation , delivery instruments set , dressing drum medium , stainless steel tray , dressing trolley , suction pump foot operated , linen trolley , pulse oximeter , water cooler with purifier , all in one computer , free standing table , executives office table , providing and fixing vertical blinds of approved make shade , providing and arrangement of mid back , kitchen trolly , public seating chair , low height openable storage , full height steel storage , multiple compartment lockers , credestal , single bed , conference table , pedestal fan , tube light , buckets , mugs , lpg stove , drum with a tap for storing water , coat rack , writing tables with table sheets , plastic chairs for in patients attendants , armless chairs , full size steel almirah , inverter
Tender For purchase of ece department lab electronics equipments - equipments for ece, dual output regulated dc variable power supplyinput voltage : 230v/50hz acoutput voltage :(0-30)v dcoutput current :(0-2)a dcprotection circuit : over voltage, over current, and short-circuit protectionhigh efficiency : greater than 85%low ripple and noise : less than 50 mvdigital display, function (signal) generatorspecs:frequency range : 0.1hz to 5mhzdisplay :4 to 6 digit led displayoutput waveforms : sine, triangle, square, pulse, rampamplitude :0-20 vpprise time :100 nsdistortion : 1% within specified frequency rangepower supply : 230v ac 10% , 50-60 hzoutput amplifier protection : short circuit and 15voverload protectiondc offset: 0 to 10 v adjustableattenuation: 0 to -60 db, decade resistance box range : 1 to 1m rotary switch selection with 6 dialssteps : 1 , 10 , 100 , 1k , 10 k , 1m accuracy : 1%, decade capacitance box range : 100 pf to 100 frotary switch selection with 6 dialsmaximum voltage : 350vaccuracy : 1%, decade inductance box range : 10 h to 10 hrotary switch selection with 6 dialslow-loss inductorsaccuracy : 1%, sim reader trainer kitpower supply :operates on 230v ac 10%, 50hz mains supplybuilt-in regulated smps power supplyoperating dc supply : 5v/12v with overload and short-circuit protectionsim card interface :supports gsm sim cards compatible with 2g / 3g / 4g / 5g networkssim card read/write interfacesupports sim card initialization, authentication and communication functionscompatible with standard 6-pin / 8-pin sim card socketscommunication interface :usb 2.0 interface for pc communicationrs-232 serial communication interfaceuart communication facility for embedded system interfacingsim operating parameters :selectable sim clock frequencies3.579 mhz7.159 mhz14.318 mhzsim supply voltage selection facilitysim reset and activation controlsupported protocols and standards :gsm etsi 07.07 and etsi 07.05 at command supportiso/iec 7816 smart card communication supportsim communication command monitoring facilityhardware features :on-board sim card socketled indication for :power statussim detectionreset activityuser manualutility software cd / downloadable software packagedata transmission/receptionbuilt-in keypad for standalone operation.lcd display module (128 64) for menu and status display.on-board microcontroller-based control section.software support:at command execution and monitoring software.sim manager utility software.data logging and communication terminal utility.pc-based gui software for sim data communication experiments.trainer features:fault simulation facility for troubleshooting experiments.simulation of faults such as:sim not detectedclock failurevcc failurereset failuremultiple on-board test points for signal observation.test points for:sim rstsim_clksim iovccuart tx/rxsuitable for cro/dso signal monitoring.glass epoxy pcb with educational block diagram layout.compact tabletop enclosed cabinet design.construction:front panel with printed block diagram.banana test points and patching facility.standard accessories:gsm sim trainer unit.usb communication cable.rs-232 communication cable.power cord., microwave test bench with reflex klystron oscillatormicrowave source :relex klystron tube with klystron mountoperating frequency in x-band (8.2ghz to 12.4ghz)electronic tuning through repeller voltage controlsuitable for cw microwave generationklystron powersupply:regulated klystron power supply unitbuilt-in modulation facilityoverload and short circuit protectionoperates on 230v ac 10%, 50hz mains supplywaveguide components:isolator variable attenuatorfrequency meterslotted line section with tunable probecrystal detector mountmatched loadmovable short / terminationwaveguide stands and accessoriesmeasurement unit:solid state vswr meter with high sensitivityswr measurement facilitysuitable for detector output monitoringtechnical specification :frequency range : 8.2 ghz to 12.4 ghzwaveguide types : wr-90detector type : crys
Tender For purchase of ece lab electronics equipments - equipments for ece, dual output regulated dc variable power supplyinput voltage : 230v/50hz acoutput voltage :(0-30)v dcoutput current :(0-2)a dcprotection circuit : over voltage, over current, and short-circuit protectionhigh efficiency : greater than 85%low ripple and noise : less than 50 mvdigital display, function (signal) generatorspecs:frequency range : 0.1hz to 5mhzdisplay :4 to 6 digit led displayoutput waveforms : sine, triangle, square, pulse, rampamplitude :0-20 vpprise time :100 nsdistortion : 1% within specified frequency rangepower supply : 230v ac 10% , 50-60 hzoutput amplifier protection : short circuit and 15voverload protectiondc offset: 0 to 10 v adjustableattenuation: 0 to -60 db, decade resistance box range : 1 to 1m rotary switch selection with 6 dialssteps : 1 , 10 , 100 , 1k , 10 k , 1m accuracy : 1%, decade capacitance box range : 100 pf to 100 frotary switch selection with 6 dialsmaximum voltage : 350vaccuracy : 1%, decade inductance box range : 10 h to 10 hrotary switch selection with 6 dialslow-loss inductorsaccuracy : 1%, sim reader trainer kitpower supply :operates on 230v ac 10%, 50hz mains supplybuilt-in regulated smps power supplyoperating dc supply : 5v/12v with overload and short-circuit protectionsim card interface :supports gsm sim cards compatible with 2g / 3g / 4g / 5g networkssim card read/write interfacesupports sim card initialization, authentication and communication functionscompatible with standard 6-pin / 8-pin sim card socketscommunication interface :usb 2.0 interface for pc communicationrs-232 serial communication interfaceuart communication facility for embedded system interfacingsim operating parameters :selectable sim clock frequencies3.579 mhz7.159 mhz14.318 mhzsim supply voltage selection facilitysim reset and activation controlsupported protocols and standards :gsm etsi 07.07 and etsi 07.05 at command supportiso/iec 7816 smart card communication supportsim communication command monitoring facilityhardware features :on-board sim card socketled indication for :power statussim detectionreset activityuser manualutility software cd / downloadable software packagedata transmission/receptionbuilt-in keypad for standalone operation.lcd display module (128 64) for menu and status display.on-board microcontroller-based control section.software support:at command execution and monitoring software.sim manager utility software.data logging and communication terminal utility.pc-based gui software for sim data communication experiments.trainer features:fault simulation facility for troubleshooting experiments.simulation of faults such as:sim not detectedclock failurevcc failurereset failuremultiple on-board test points for signal observation.test points for:sim rstsim_clksim iovccuart tx/rxsuitable for cro/dso signal monitoring.glass epoxy pcb with educational block diagram layout.compact tabletop enclosed cabinet design.construction:front panel with printed block diagram.banana test points and patching facility.standard accessories:gsm sim trainer unit.usb communication cable.rs-232 communication cable.power cord., microwave test bench with reflex klystron oscillatormicrowave source :relex klystron tube with klystron mountoperating frequency in x-band (8.2ghz to 12.4ghz)electronic tuning through repeller voltage controlsuitable for cw microwave generationklystron powersupply:regulated klystron power supply unitbuilt-in modulation facilityoverload and short circuit protectionoperates on 230v ac 10%, 50hz mains supplywaveguide components:isolator variable attenuatorfrequency meterslotted line section with tunable probecrystal detector mountmatched loadmovable short / terminationwaveguide stands and accessoriesmeasurement unit:solid state vswr meter with high sensitivityswr measurement facilitysuitable for detector output monitoringtechnical specification :frequency range : 8.2 ghz to 12.4 ghzwaveguide types : wr-90detector type : crystal detecto
Tender For purchase of lab equipments for eee dept - purchase of lab equipments for eee dept, single phase transformer.itemcode:b002 single phase transformer,rating: 1 kva, 50 hz, input: 230 v acoutput: 115 v ac,type: air-cooled, single-phase step-down transformer properly insulated input and output terminals brought out for safe operation)., acidity test kit itemcode:b005specifications:ethyl alcohol sodium carbonate solution universal indicator solution laboratory-grade test tubes droppers colour comparison chart for test result comparison chemicals supplied in labelled containers with safety instructions suitable for laboratory educational and testing applications, dc stepper motor drive kit with stepper motoritemcode:b010specifications:stepper motor : permanent magnet / hybrid type with suitable driver circuits. motor operating voltage : 12 24 v dc variable speed control forward and reverse direction control full step and half step operation manual / automatic pulse generation facility built-in regulated dc power supply led indication for phase sequence and status test points provided for waveform observation start / stop control switches to be provided overload and short circuit protection to be provided mounted on compact powder coated cabinet withprinted circuit diagram proper insulated terminals and interconnecting leads to be provided patch chords for interconnection, dc servo motor drive kit with servo motor itemcode:b011specifications:input supply : 230 v ac, 50 hz servo motor type : dc servo motor with feedback arrangement motor operating voltage : 12 24 v dc controller type : microcontroller based servo drive controller speed control : variable speed control to be provided position control : angular position control facility to be provided direction control : forward and reverse operation feedback device : encoder / potentiometer based feedback system built-in regulated dc power supply led indications for power and status test points to be provided for signal observation and analysis start / stop control switches provided overload and short circuit protection to be provided mounted on powder coated cabinet with printed circuit diagram proper insulated terminals and interconnecting leads to be provided, three phase resistive load itemcode:b013specifications:rating: 5.25 kw supply: 415 v ac, 3-phase, 50 hz total number of load steps: 6 main switch to be provided approximate dimensions: 18 18 22 inches (l b h) comprising special cement-insulated electrical load resistors mounted on powder-coated ms panel/enclosure individual on/off rotary switches for load selection mounted on rubber wheels/casters for portability suitable for laboratory load testing applications proper insulation, ventilation, and earthing arrangement to be provided, single phase single pulse / sinusoidal pwm inverter using mosfet/igbt kit itemcode:b028specifications:type : single phase pwm inverter trainer power device : mosfet / igbt based inverter circuit input supply : 12 24 v dc output voltage : 30 v rms ac output phase : single phase output frequency : 0 50 hz variable output power : 100 w single pulse pwm operation sinusoidal pwm (spwm) operation variable frequency control pwm generation and firing control circuit inbuilt gate drivercircuit provided test points provided for waveform observation and analysis built-in resistive load provision, on / off control of lamp using solid state relay kit itemcode:b029specifications:type : solid state relay (ssr) trainer kit control/input voltage : 12 v / 24 v dc or up to 30 v dc output load voltage : 230 v ac, single phase load control : on/off control of ac lamp load solid state relay based switching circuit opto-isolated input control built-in ac lamp load manual on/off switching arrangement led indication for input and output status, speed control of ac motor using vfd drive module with ac motor itemcode:b030specifications:type : variable frequency drive (vfd) module input supply : 415 v ac, three phase, 50 hz o
Tender For supply of eee lab items dept use - three phase transformer rating: 3 kva input voltage: 415 v ac, 3-phase output voltage: 230 v ac, 3-phase frequency: 50 hz winding material: copper wound insulation class: class b or higher duty: continuous duty suitable for laboratory usebench/floor mounted suitable for laboratory operation all winding terminals shall be brought out to insulated terminals and enclosed within a protective outer cover for safe laboratory operation , dc stepper motor driver kit with stepper motorinput supply : 230 v ac, 50 hz stepper motor : permanent magnet / hybrid type with suitable driver circuits. motor operating voltage : 12 24 v dc variable speed control forward and reverse direction control full step and half step operation manual / automatic pulse generation facility built-in regulated dc power supply led indication for phase sequence and status test points provided for waveform observation start / stop control switches to be provided overload and short circuit protection to be provided mounted on compact powder coated cabinet with printed circuit diagram proper insulated terminals and interconnecting leads to be provided patch chords for interconnection. , dc servo motor driver kit with servo motorinput voltage 12 - 24v, dc, 5a, 10-60rpminput supply : 230 v ac, 50 hz servo motor type : dc servo motor with feedback arrangement motor operating voltage : 12 24 v dc controller type : microcontroller based servo drive controller speed control : variable speed control to be provided position control : angular position control facility to be provided direction control : forward and reverse operation feedback device : encoder / potentiometer based feedback system built-in regulated dc power supply led indications for power and status test points to be provided for signal observation and analysis start / stop control switches provided overload and short circuit protection to be provided mounted on powder coated cabinet with printed circuit diagram proper insulated terminals and interconnecting leads to be provided , three phase resistive loadrating: 5.25 kw supply: 415 v ac, 3-phase, 50 hz total number of load steps: 6 main switch to be provided approximate dimensions: 18 18 22 inches (l b h) comprising special cement-insulated electrical load resistors mounted on powder-coated ms panel/enclosure individual on/off rotary switches for load selection mounted on rubber wheels/casters for portability suitable for laboratory load testing applications proper insulation, ventilation, and earthing arrangement to be provided , single phase induction motor with load arrangement 5hp ,230v, 1400 rpmsingle phase, 2hp,230v,1440 rpm with dol starter loading arrangement and electrical workbench mechanical rope with aluminum brake drum loading with adjustable wheels - 2 no s 0-50 kg spring balance - 2 no s electrical panel board with workbench -cupboard with door. panel board- with proper internal wiring& terminals insulated necessary symbols of motor and starter, fuse, supply indicators to be provided and printed on panel board -digital rpm indicator with proximity sensor to be provided -required number of digital ammeter , three phase synchronous motor with electrical workbench 3-phase synchronous motor with electrical workbench and loading arrangement , rating: 5 hp voltage: 440 v ac, 50 hz speed: 1500 rpm (synchronous speed), induction start using damper winding, suitable starter panel, dc supply (0 220 v dc adjustable (variable dc control) within the panel),and necessary workbench electrical panel board with workbench -cupboard with door. panel board- with proper internal wiring& terminals insulated necessary symbols of motor , starter, exciter, fuse, supply indicators to be provided and printed on panel board -digital rpm indicator with proximity sensor to be provided -required number of digital ammeters and voltmeters for motor to be provided on panel board. , synchronizing panelthree phase, 415v, 15a synchronizi
Tender For supply of lab equipments - purchase of lab equipments, acidity test kitspecifications:ethyl alcohol sodium carbonate solution universal indicator solution laboratory-grade test tubes droppers colour comparison chart for test result comparison chemicals supplied in labelled containers with safety instructions suitable for laboratory educational and testing applications, single phase resistive loadspecifications:type: single phase loading rheostat power rating: 5 kw supply: 230 v ac, single phase, 50 hz total number of load steps: 8 approximate dimensions: 18 18 22 inches (l b h) comprising electrical load resistors suitable for laboratory loading applications resistors shall be special cement-insulated type mounted on powder-coated ms panel/enclosure individual on/off rotary switches provided for load selection mounted on rubber wheels/casters for portability, three phase resistive load specifications:rating: 5.25 kw supply: 415 v ac, 3-phase, 50 hz total number of load steps: 6 main switch to be provided approximate dimensions: 18 18 22 inches (l b h) comprising special cement-insulated electrical load resistors mounted on powder-coated ms panel/enclosure individual on/off rotary switches for load selection mounted on rubber wheels/casters for portability suitable for laboratory load testing applications proper insulation, ventilation, and earthing arrangement to be provided, three phase capacitor bank specifications: 3-phase capacitor bank rating: 2 kvar voltage: 440 v ac frequency: 50 hz heavy duty self-healing capacitor units powder coated ms enclosure compact panel mounted/floor mounted construction proper ventilation arrangement to be provided capacitor duty contactor/switch to be provided fuse/mcb protection to be provided discharge resistors to be provided for safety proper earthing arrangement provided, 3 phase auto transformer starter specifications: 3-phase variable autotransformer input: 415 v output: 0 470 v ac (continuous) current: 15 a copper wound, carbon brush type heavy duty toroidal/core construction mounted in powder coated ms/crca enclosure front panel mounted voltage control knob with scale indication proper insulated terminals provided floor/bench mounted type suitable for laboratory use input / output terminal arrangement provided mcb/fuse protection provided proper earthing terminal provided ventilation arrangement for heat dissipation, 3 floor lift interfacing model specifications: type: table-top lift model floors: 3 levels structure: transparent acrylic / ms frame cabin: moving lift car with guide rails drive: dc geared motor / stepper motor motion: up/down movement, floor indication leds (1, 2, 3) direction indicators (up/down), start & stop atevery stage, over load limit control three-floor lift operation plc interfacing and programming floor selection logic automatic stopping at floors direction indication system educational demonstration of elevator automation, mcb elcb trainer kit specifications: 1 phase/3 phase, 2/3/4 pole, 3a-16a single pole mcb 2-5amps two pole elcb 30ma lamp load single phase 5amps panel enclosure and terminal outlets, signal generator specifications: frequency range: 0.1 hz to 5 mhz. display: 4 to 6 digit led display output waveforms: sine, triangle, square, pulse, ramp. amplitude: 0 20 vp-p. rise time: 100 ns. distortion, dso specifications: bandwidth: 50 - 100 mhz. sampling rate: 1gs/s. channels: 2 (minimum) power supply: 100v 240v ac, 50-60 hz automatic measurement: vpp, vavg,rms, frequency, period, vmax, vmin, rise time, fall time, + width, - width, +duty, - duty etc., horizontal scale: 5 ns/div 50 s/div or equivalent vertical resolution: 8 bits (2 channels simultaneously) vertical sensitivity: 1 mv/div 10 v/div (at input) waveform math: +, -, x , , invert, fft etc., waveform storage: 16 waveforms or equivalent communication interface: usb host, usb interface. 7-inch color display or equivalent input impedance - 1 m 2%, // 20 pf 2 passive probes (1x/10x), pwm based
Tender For procurement of hospital consumables items - adhesive tape (width 5 cm x length 5 m), disposable syringe, sterile hypodermic, non toxic, non pyrogenic, single use (2 ml), disposable syringe, sterile hypodermic, non toxic, non pyrogenic, single use (5 ml), disposable syringe, sterile hypodermic, non toxic, non pyrogenic, single use. central luer slip, ribbon pack (10 ml), surgical rubber gloves, pre-powdered, for single use, anatomically shaped for comfort, textured surface for excellent instrument grip (6.5 ’’), surgical rubber gloves, pre-powdered, for single use, anatomically shaped for comfort, textured surface for excellent instrument grip (7’’), surgical rubber gloves, pre-powdered, for single use, anatomically shaped for comfort, textured surface for excellent instrument grip (7.5’’), infusion set, eto sterile, non-pyrogenic, non toxic, single use, 1 ml ± 20 drops (per ml d.w)needle size 21/g gravity feed only (standard), blood administration set, sterile, non toxic, non-pyrogenic , gravity feed, dehp free, single use only, 20 drops of distilled water equivalent to 1 ml ± 0.1 ml (1g ± 0.1 g) (standard), pulse oximeter (handy), display – oled/ lcd, battery- 3v : 2aaa, spo2 measuring range – 35% to 100%, accuracy - ± 2bpm or ± 2% (standard), nasal oxygen catheter , 2 m long multichannel kink resistant tube with extra soft medical grade nasal tips, sterile, non-toxic, single use (standard), accu-sure blood glucose test strips , no-coding system, accu-sure blood lancet, sterile, round (100 units pack), urine collection bag with top outlet & non-return valve, disposable, non-toxic, non-pyrogenic, single use, capacity – 2000 ml (adult), oxygen mask, sterile ,soft, flexible, medical grade, star lumen, for single use (adult), nebulizer mask, with aerosol mask (elastic strap) 2 meter long multi channel tubing, sterile single use (adult), latex examination gloves, powdered, non-sterile, ambidextrous, single use (large size), disposable surgical 3 ply face mask, anti allergic, fluid resistance, optimal comfort high particle filtration (adult), disposable surgical cap, sterile, medical grade, spandex and polyester elastic, (adult), i.v cannula with injection port & wings, 20g, 1.1 x 32mm, 61ml/min (standard), i.v cannula with injection port & wings, 18g, 1.1 x 32mm, 61ml/min (standard), cannula fixator, extra strip for additional adhesion (standard), round spot band-aid , material – cloth, adhesive (l x w x h = 50 x 80 x 45 millimeters), urine collection container, sterile (60 ml), enema kit for adults, reusable & washable, polyvinyl chloride make (1500 ml), clot activator blood collection tube, vacuum, medical grade pet, transparent, 4.0 ml, clot activator coated on the inner wall to accelerate clotting, pre-sterilized & disposable (13 x 75 mm), k3 edta blood collection tubes, vacuum, medical grade pet, 2ml, transparent, pre-sterilized & disposable (13 x 75 mm), sodium fluoride blood collection tube, vacuum, medical grade pet, transparent, 2.0ml (13 x 75 mm), prothrombin time collection tube, vacuum, medical grade pet, transparent, 2.7ml tubes, pre-sterilized & disposable (13 x 75 mm), biomedical waste carrying bag colour – blue/yellow/red/black non chlorinated bis -9738 certified polymer made, biomedical waste bag thickness minimum 120 micron and manufacturer details should be printed on the bag. the bag should be leak proof and the bmw bag must include one cable tie. all bags are to be customized with biohazard symbol, preprinted as per wbpcb norms (size – 65 cm (b) x 80 cm (l) for 50 litre), biomedical waste bin – colour – blue/yellow/red/ black, high density polyethylene (hdpe), 50 ltr capacity, weight – 3.5 kg (approx), all bins are to be customized with biohazard symbol (dimension (l*w*h) 415 x 425 x 615 mm (approx.), electric needle cutters , weight-0.3kg to 2 kg, power consumption- 60w-100w, burning temperature-16000c, abs plastic body with stainless still, removal drawer for waste collection (dim
Tender For corrigendum : supply of laboratory and other items for gsecl wtps hospital c c - h 560 diluent. , h 560 lyse 1. , h 560 lyse 2. , h 560 controls h n l , h 560 calibrator. , h 560 elite h clean. , pm kit for h 560 , blood sugar 10 multiply 44ml system pack , calcium 10 multiply 12ml system pack , cholesterol 10 multiply 44ml system pack , creatinine system pack , erba norm , erba path , hdl direct system pack , sgot system pack , sgpt system pack , bilirubin system pack , triglyceride diagnostic kits lab test , uric acid system pack , multical , erba wash , crp test kit , pm kit for em-200 , chikenguniya ag or ab kit , clot activatior tube , dengue antigen igm , edta 3k tube 1 x 2 ml , flouride tube for lab use , pf or pv antigen strip , strip for pregnancy test , glucose stripe , urine container , urine multistixs , s widal antigen kit , x-ray devloper , x ray film 12inch mul 15 inch , x-ray fixer , sodium hypochloride , blood group kit , hiv-aids card , hbsag cards diagnostic kits lab test , pippet tips blue miscellenious items , yellow micropipette tips. , sample cup for clinical analyzer. , surgical gloves no. 6 gloves , surgical gloves no. 7.5 gloves , tourniquet belt. , antiseptic liquid 1000ml. , antiseptic liquid 100ml. , weighing scale digital , digital blood pressure instrument , ecg roll , ecg jelly , glucometer , b.p. instrument , tissue paper for napkin form , pulse oxymeter , stethoscope , typhi dot card ag and ab card , portable digital tds meter. , micropipette 100ul-1000ul. , micropipette 20ul.
Tender For bid to ras corrigendum : supply of bi facial solar panel 550 watt , topcon solar panel 610 watt , cut section of gate valve,globe valve,ball valve,diapharm valve,needle valve,check valve,safety valve,butterfly valve,pnematic control valve 4 inch diameter , cut section of centrifugal pump,gear pump,multistage c f pump,reciprocating pump,screw pump , cut section of shell and tube heat exchanger acrylic material , cut section of reactor with accessories motor,agitatot,support leg,nozzle,manhole,baffels,thermo well,bottom valve , vrf or vrv unit with two indoor unit 2 point 5 tr each and 5 tr capacity out door unit complete with air cooled condenser,accessories and controls,harmetic shield type compresor,r410 a single phase , evacuating and charging station as above but fitted with weighing scale 0 point 25 hp,230v,50 hz with gauge manifold , gauge manifold with gauges different size of hoses for r134a,r22,r32 and r 410 , wash bag cover jacket for ac service indore 1 point 5 ton,2 point 5 ton capacity , safety belt, industrial type full body protection double rope double hook,100 kg human weight , embroidery machine , brake test arrangement with two spring balance 0 to 25 kg rating , automatic motor coil winding machine with step arbor , three phase variable auto transformer ac varic 3 phase , 0 to 440v, 25a, 50 hz , synchronous motor, with accessories , vfd ac drive ac motor drive with vvvf control 3 phase , single phase transformer, core type, air cooled,1 kva,240 or 415 v,50hz , stepper motor with digital controller , bipolar , 12v dc , input pulse 5v, step angle 1 point 8 , power supply 230 v ac , oprating condition 0 to 40 deg c , bldc motor fan with controller 40 watt , servo motor with contoller 300rpm,12v dc,6mm dia and 15mm legth shaft ,holding torque 30kg cm,no load current 0 point 8 amp,full load current 7 point 5 amp , electrical test bench integrated with 0 to270v ac variac 25a , synchronization trainer for laboratory , solid flow measurement set up bi facial solar panel 550 watt,efficiency 21.3 percentage,dimension 2285mm x 1134mm x 35 mm,anodized aluminumsilver frame,connector mc4 ev02,maximum system voltage 1500v dc, topcon solar panel 610 watt,efficiency 22 point 6 percent to 22 point 9 percent,n type topcon,dimension 2382x1134x30 mm,2 mm dual glass,maximum system voltage 1500v dc, cut section of gate valve,globe valve,ball valve,diapharm valve,needle valve,check valve,safety valve,butterfly valve,pnematic control valve 4 inch diameter, cut section of centrifugal pump,gear pump,multistage c f pump,reciprocating pump,screw pump, cut section of shell and tube heat exchanger acrylic material, cut section of reactor with accessories motor,agitatot,support leg,nozzle,manhole,baffels,thermo well,bottom valve, vrf or vrv unit with two indoor unit 2 point 5 tr each and 5 tr capacity out door unit complete with air cooled condenser,accessories and controls,harmetic shield type compresor,r410 a //bid details 2 / 25