Tender For corrigendum : supply of supply, installation, testing and commissioning of microprocessor based intelligent addressable main fire alarm control panel with 2 loops modules , supply, installation, testing and commissioning of intelligent addressable multi criteria detector with a combination of optical and thermal including mounting base , supply, installation, testing and commissioning of intelligent addressable smoke detector including mounting base with led , supply, installation, testing and commissioning of addressable weather proof outdoor manual call point with ip rating of ip 67 , supply, installation, testing and commissioning of addressable loop powered stand alone sounder outdoor with inbuilt isolators , supply, installation, testing and commissioning of active repeater panel to be connected peer to peer with main fire alarm panel
Tender For corrigendum : tender for supply of fdas devices - optical smoke detector iq8 typeo 802371 , fire alarm beacon , red , 11.3 to 42.4 c , fire alarm hooter , smoke detec open path 5-50mtr 252490.02 , response indicator , ri
Tender For annual maintenance contract comprehensive of glory company note counting with fake notedetectionmachine (model - ntgera pro (1+1) 52 machines and model 300 (3+1)-2 machines) total 54 machines 50 branches, 03 extension counters & 2 cash department usf spread in brihanmumbai.
Tender For corrigendum : tender for supply of fire alarm : -morleyias-make multi-protocol fire alarm control panel(model -zx5e) , zx5e panel loop driver card for morleyias protocol , morleyias-make optical fire detector (model no. - mi-pse-s2-iv) , zx5e panel loop driver card for apollo protocol , lcd display card of zx5e fire alarm control panel
Tender For bid to ras supply of refurbishment of room flooding system of server room at sauw ins satavahana c c -refilling of hfc 227ea gas 1,1,1,2,3,3,3 hepta fluro propane, zero odp, stored pressure, gas , conventional gas release panel with battery backup and cross zoning facility 2-zone with fire ext automatic mini intuitive fk-5-1-2 300gm ss sp red 79 c with nrv , ms container strap for mounting and fixing the agent containers to the wall , ul container strap for mounting and fixing the agent container to the wall , valve assembly and arrangement for supervisory switch connection for monitoring cylinder pressure, a pressure gauge with a safety burst disc and a safety cap 25 bar , pressure gauge cum switch for monitoring the cylinder pressure 0-60 bar, 22. 50 bar switch point pressure switch wasco switch point 5bar 72. 5 psig imp with fire ext automatic wm fk 5-1-12 4kg , hydro static pressure test 50 bar, inverted baker test, helium leak detection test, epoxy powder painting, dismantling, commissioning charges , conventional optical smoke detector with double dust trap chamber design, optimized performance using internal algorithm, central led for 360 status visibility, compiles to en 54-7 standard , conventional rate of rise heat detector, heat alarm threshold temperature 58 c central led for 360 status visibility, complies to en 54-7 standard and approved by lpcb, vds , installation and delivery charges