Tender For provision of 01 x 30 kva genr with connected items as standby power requirements for sewage treatment plant under age (i) bhalra - supply, installing, commissioning and testing, water cooled, sound proof silent type, turbo charged, diesel engine driven generating set 30 kva (at 0.8 pf), 415v, 3 phase, 4 wire engine as per is: 10001/10002 and alterator as per is: 13364, complete with relay panel for automatic starting on mains failure, control panels having meters in an integral acoustic enclosure as per recommendation cpcb norms, comprising of the following:notes: quoted rates shall deemed to include the following also:-(i) supply of t and p and normal space ie., bi-hexagonal ring spanner set of 12 pieces - 01 set.(ii) fuel measuement gauge - 01 no, hand operated fuel lifting pump with steel pipe 40mm dia - 01 no, hydro meter - 01 no, set of fan belt, oil/ fuel filters initial filling of coolant (coolant-2liters).(iii) service maintenance manual along with cat part list and price list - 03 set each.(iv) make of engine and alternator will be got approved from age (i) bhalra before placing the order., (a) diesel engine. diesel engine developing suitable bhp, 1500 rpm inclusive of the following standard accessories:(i) radiator/ heat exchanger cooling system. (xiv) battery charging generator.(ii) spider coupling guard. (xv) industrial silencer.(iii) fly wheel. (xvi) lubricant oil cooler.(iv) fly wheel housing complete with starter gear ring and coupling. (xvii) flexible pipe for silencer. (v) fuel pipes. (xviii) battery volt meter.(vi) air cleaner. (xix) water temperature gauge, lub oil pressure (vii) fuel and lubricant oil filter. gauge.(viii) by pass filter. (xx) speedo meter and engine running hours meter.(ix) coolant inhibitor. (xxi) display for fault.(x) fuel pump. (xxii) turbo charger.(xi) water pump. (xii) lubricant oil pump.(xiii) self/electric starter.(b) alternator : synchronous alternator 3 phase 4 wire, 50 cycles 1500 rpm, self excited, self regulated, brushless type, 0.8 pf, 415v, ac supply, 30 kva capacity, copper wound, complete including necessary tools, mounted on strong rigid steel fabricated base frame and directly coupled through flexible coupling with diesel engine, complete all as specified and directed., (c) amf/ control panel : amf panel factory made of suitable capacity as per original equipment manufacturer make and specification or as approved by oem for dg set of capacity 30 kva of suitable size, indoor cubical type, front and back openable fabricated out of mild steel sheet 1.6mm thick grounted in floor with adequate pcc foundation and minimum consisting of following :(i) contactor of suitable size for 30 kva dg set.(ii) copper bus bar of suitable current rating and sensitivity relay set unit with auxiliary cts.(iii) electronic latch circuit with tripping indication.(iv) re-set facilities.(v) 3 phase mvr relay unit with single phase protection complete with 2 no nc auxiliary contacts.(vi) 3 phase avr relay unit complete.(vii) self sequential starting relay unit 12 volts dc complete with alarm and power contactor. (viii) electronic timer 220 volts for main contactor with 1 no nc auxiliary contactor.(ix) electronic timer 220 volts for fuel cut off operation with 1 no auxiliary contactor.(x) battery charging 2x12 volts 10 amp complete with digital voltmeter and amps meter, including trickle and boost charging, make : su-kam, amco, exide or any other make as recommended by the manufacturer.(xi) volt meter 0-500 volts panel mounting of size 96mm square with selector switch digital type.(xii) amps meter 0-100 amps with 3 nos cts, 400/5 and selector switch 96 mm square digital type.(xiii) frequency meter (45-55) hz, 415 volt, 96mm square digital type.(xiv) the amf panel should have manual by pass arrangement too in case of failure of amf panel., (d) fuel tank of capacity as per manufacturer recommendations.(e) base frame made out of suitable channel duly reinforced and provided with adequate numbers of anti
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - hydro power plant gsecl sshep kevadia colony; as per atc; as per atc
Tender For bid to ras corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - hydro power house; overhauling repair and centring of 20t semi-gantry crane no 2 at dph slapper; as per scope of work
Tender For corrigendum : repair, maintenance, and installation of plant/ systems/equipments (version 2) - industry unit; tender for the job of obtaining consent to establish for hter scheme at rcf thal unit through nipl route; as per scope of work; a) safety violation by contractor employee at work place: 1) working without wearing safety helmet (per person), 2) working without wearing safety shoes (per person), 3) working without wearing safety goggle &/or hand gloves during handling of hazardous chemicals, acid/alkali etc. (per person), 4) working without wearing safety belt (double lanyard full body harness) for height jobs above 2 meters. (per person), 5) working without wearing face shield during cutting, welding, grinding activity and during maintenance work on process lines and equipment. (per person), 6) not using ppe, tools/tackles as mentioned in safety work permit (per person), 7) working without valid test certificate for lifting tools/tackles (per incidence observation), 8) working without appropriate electric plug-pin, elcb/rccb/rcbo (per incidence observation), 9) working without a valid safety work permit (per incidence/ observation), 10) permit not available at site (per incidence/observation), 11) gas cylinder without flash back arrestor (per incidence observation), 12) gas cutting set with damaged hose pressure gauge without valve key (per incidence/observation), 13) gas cylinder without trolley (filled and empty) (per incidence/ observation), 14) unauthorized personal entering into cordon off area (per incidence/observation), 15) faulty wire/cable laying on ground or using snapped cables (per incidence/observation)., 16) improper hand tool or power tools (per incidence observation), 17) smoking at work place area. (per person), 18) found in intoxicated state (per person), 19) violation of road rules (per incidence observation), 20) b) safety violations by transport contractors, 21) faulty hazchem displayed on tanker (per incidence observation), 22) one pvc/tychem suit set if available (per incidence/ observation), 23) both pvc/tychem suit set are not available (per incidence observation), 24) fire extinguisher without hydro test. (per incidence/ observation), 25) trem card not available (per incidence/observation), 26) hazardous chemicals transportation training of driver by authorized agencies. (training card not available with driver) (per person), 27) lying/resting below the vehicle(per incidence/observation), 28) any other deviation found as per checklist for tankers (per incidence/ observation.
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - wt-5154g (mmd hps - minihydro) - work of repairing / refurbishment of guide vane servomotor cylinder of 2 x 2pt5 mw mini hydro power station, gsecl, ukai, gujarat; guide..
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - thermal power plant; work of cleaning of tubes of various coolers of coal mill id fan pa fan and aph by hydro drilling with inserting hard nylon and ss brushes by high ..
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - tehri hydro power complex (tehri hpc); installation of crash tested tyre killer at adit 3 of tehri hpp bearing mounting in tyre killer installed at adit 2 of hpp and con..
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - hydro power house; rebabbating of inner shell of turbine guide bearing; as per sow