Get complete information related to latest Ocb Panel Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ocb Panel Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ocb Panel Tenders.
Tender For supply of non - modular piano type domestic electrical switches as per is 3854 (q3) , piano type non modular domestic fan regulator as per is 11037 (q3) , piano type modular domestic fan regulator as per is 11037 (q3) , piano type non modular electrical switch socket combination as per is 3854 and is 1293 (q3) , piano type non modular domestic electrical sockets - is 1293 (q3) , ceiling rose - is 371 (q3) , electrical plugs (v2) isi marked to is 1293 (q2) , piano type modular domestic electrical sockets - is 1293 (q3) , modular electrical enclosure switch board boxes for modular type accessories (q3) , modular socket 6 amp 5 pin , modular switch 16 amp , modular switch 6 amp , angle holder , batten holder , socket flush type 5 to 6 amp with 3 to 5 pin , heat shrinkable straight through 95 sqmm x 3 core, 11 kv end terminatrion. , heat shrinkable straight through 120 sqmm x 3 core, 11 kv end terminatrion. , heat shrinkable cable joint 10 sqmm 2 core , heat shrinkable cable joint 16 sqmm 2 core , heat shrinkable cable joint 10 sqmm , heat shrinkable cable joint 16 sqmm , heat shrinkable cable joint 25 sqmm , heat shrinkable cable joint 35 sqmm , heat shrinkable cable joint 50 sqmm , heat shrinkable cable joint 70 sqmm , heat shrinkable cable joint 95 sqmm , heat shrinkable cable joint 120 sqmm , heat shrinkable cable joint 150 sqmm , heat shrinkable cable joint 185 sqmm , heat shrinkable cable joint 240 sqmm , condensor 2.5 mfd , condensor 4 mfd , ding dong bell , buzzer electric , insulationtape 15 mm x 25 mtr long , insulationtape 20 mm x 25 mtr long , insulation tape 25 mm x 25 mtr long , ht tape , pvc casing caping 20mm , pvc conduite pipe 25mm , pvc conduite pipe 32mm , pvc saddle clip for cable 8 mm , pvc saddle clip for cable 25 mm , heating element 2000w cup or thread type , heating element 2000w , heating element 1500w , 3 kw heating element , gasket for transformer sheet , foam for gap filling in electrical panel db and 1 ltr pkt , crc liquid for preventing corrosingn and 500 ml pkt , geyser element 2 kv , ac gang box switch socket and top with mcb 25 amp , change over switch 100 amp , change over switch 200 amp , change over switch 400 amp , contactor mnx-50 , contactor mnx-70 , contactor mnx-95 , modular cover plate 3 module with frame , modular cover plate 4 module with frame , modular cover plate 6 module with frame , cotton waste , pig lead , lead acid battery 12 v 90_100 ah , lead acid battery 12 v 90_150 ah , lead acid battery 12 v 90_180 ah , thermostate for geyser , astronomical timer for street light control , soft starter vfd suitable for 50 hp motor , kit fan motor for desert cooler , water pump 40 watt for deser cooler , fully automatic oil immersed auto transformer motor starter , fully automatic oil immersed auto transformer motor starter for 75hp motor , compressor 220- 280 v, weight 18 kg for split ac 1.5 or 2 tr , compressor 50 plus 4 or 50 plus 6 mfd rotary type suitable for split ac 1.5 or 2 tr , electronic pcb plate for split and window ac suitable for 1.5 or 2 tr , solar street light ng series 40 w //bid details 2 / 85
Tender For b9)-a/mtc. of ephs (w/s) in sector-6, u/e panipat-repair of submersible pumping machineries including motor pump, electrical control panel with starter, cable with kit kats and all accessories, nrv, sv and specials etc. for tubewells
Tender For supply of upgradation of existing operation theatre to modular operation theatre d d - wall paneling , embeded glass panel , pvc flooring for ot as per tender specification , laminar air flow, exhaust cabinet, and ac ducting as per tender specification , peripheral lights and clean room luminaries as per tender specification , touch screen control panel as per tender specification , storage units for ot as per tender specifications , pressure relief damper as per tender specifications , automatic sliding door as per tender specification , hermetically sealed manual slide door as per tender specifications , glass operating board as per tender specifications , xray view box as per tender specifications , electrical installation incl distribution box internal wiring and switch socket as per tender specification , single arm anesthesia pendant with terminal unit as per tender specs , medical gas pipeline inside ot , air handling unit with odu as per tender specifications , 2 bay scrub station foot operated and toucless option , pvc flooring for connecting corridors , hatch box as per specification , operation theater light with camera as per specification
Tender For special repair replacement of broken rusted electrical cubical including burnout control switch gear apfc panel and other miscellaneous electrical work under ge (nw) mankhurd
Tender For design, engineering, supply, installation, testing and commissioning of an alert, inform and direct system at six (6) sites - control & monitoring :- the control room shall be set up in the already constructed/available room at the pandoh dam area. this system should include a minimum 43-inch (hd) screen with an adjustable stand, capable of monitoring the operation of the siren station. it should display all feedback, including the status of being on or off, battery health, any faults etc. in the installed equipment. additionally, this system must have the capability to communicate directly with the control room to provide alerts and information in real time., for supply ,testing, designing, erection and commissioning of local station for alert, information and direct system comprising of the following hardware/software: panel/housing with power supply module. the controller, linked with all the control units through a communication and integration unit, displays the system via screens. the sirens should also be remote controlled. the control of the sirens should be according to the commands received from the remote central control station through a two-way gsm/gprs/3g/4g/lte and provision of vsat. security feature including intrusion alarm auxiliary/status control board for contact closure activation and status. the siren system should withstand outdoor environment condition & the siren assembly should be rust proof to withstand harsh and saline environmental condition. single point clicks activation & polling. status monitoring. complete configuration & reprogramming for control site. minimum 15,000 message alert notification through gsm/3g/4g/5g/lte/vsat to bbmb officials/ administrators and local residents according to requirement. programmable hot keys. communication over tcp/ip secure access with password. ethernet cable length :- the bidder shall be responsible for the supply and erection of all cabling required for the complete system, ensuring that the cables are of reputable make only and conform to the prescribed standards as per site requirements. rtu & software :- the r.t.u. and software as per the manufacturer`s design / program, the software should be suitable for controls up to 100+ sirens, the system can be expanded to accommodate changing needs. the software should be app and web based. communication between control centre and sirens. :- gsm/3g/4g/5g/lte network/vsat. pre-recorded voice messages :- live and pre-recorded voice messages in minimum 3 local languages i.e. (hindi, punjabi and english) strobe light :- high intensity led strobe light, color red, amber, green, 60-120 flashes per minute (adjustable), led life > 50000 hrs., pole/top mountable with 360 visibility preferably ip 66. alert tones & voice:- minimum 5 standard alert tones. support transmission of stored voice in siren/voice controller through wave file in memory card, remote activation. remote activation of alert tones and pre-recorded voices the voice messages will be customized, optimized for good quality for the intended location, language preferably in punjabi, hindi & english. warranty period:- 3 years., input power source :- the quantity of solar photovoltaic panels and batteries shall be adequate to meet the systems operational requirements. only reputed manufacturers such as tata solar, vikram, waaree, reil, or equivalent brands shall be supplied. the solar panel input source shall be integrated with the required number of batteries to run the installed system continuously for a minimum duration of three (3) days under idle running conditions. this includes six (6) operational cycles per day, with each cycle lasting a minimum of twenty (20) minutes. a secondary provision for electrical input supply shall be provided to enable system operation in the event of solar panel failure or insufficiency beyond the designed power supply capacity., siren type :- bi-directional electronic siren pre-programmed audio amp
Tender For tender for repair/replacement of damaged/defective equipments in control room/yard at various sub-stations under electrical system division hpsebl una - replacement of defective space heaters (230v ac, 40 watt) along with thermostate (1 for 2 heaters) (range 30 degree c - 85 degree c) at 66kv sub-station, gwalthai, replacement of industrial standard warm white 250 watt led light (make ;- crompton/ havells/ bajaj/ orient), high mast/ flood light, ip 65/ ip 66 compliant (one year onsite warranty) including fabrication of clamps, 2.5 sq mm cable wiring etc. as per the satisfaction of engineer in-charge at 132kv sub-station, una, replacement of industrial standard warm white 250 watt led light (make ;- crompton/ havells/ bajaj/ orient), high mast/ flood light, ip 65/ ip 66 compliant (one year onsite warranty) including fabrication of clamps, 2.5 sq mm cable wiring etc. as per the satisfaction of engineer in-charge at 132kv sub-station, amb, repalcement of control room defective led white tube light (cool whitle) 20 watt, supply voltage 220v ac (make: philips/ bajal/ crompton/panasonic) at 132kv sub-station, hpsebl amb, replacement of defective ceiling fan 1400 mm high speed 390 rpm, rust proof body supply voltage 220 v ac (make: philips/ bajal/ crompton/panasonic) at 132kv sub-station, hpsebl amb, replacement of defective 12-inch portable anti-rust exhaust fan, quiet & adjustable for any space 300 mm exhaust fan(make: philips/ bajal/ crompton/panasonic) for battery charging room at 132kv sub-station amb, replacement of defective 12 window microprocessor based alarm announciator, voltage-220 v dc (make minilec model 312b mp0 big window) at 33kv feeder panel at 132kv sub-station, hpsebl amb., replacement of defective indication lamp for c&r panel (red-15, green-15, white-5 yellow-5, blue-5) supply voltage-30v-240 v ac/dc at 132kv sub-station amb, repalcement of defective jvs tripping relay type jrv 171 voltage 220 v dc as per sample at 132kv sub-station amb, repalcement of defective jvs type tcsr relay jrv 111 voltage 220 v dc as per sample at 132kv sub-station amb, quantities are mentioned above are tentative and actual quantity shall be worked out .payment shall be made as per approved bill of material/actual quantities measured at site.
Tender For supply and installation of 85kw ongrid solar rooftop power plant and 5 years maintenance at swm site, yadapura road, arsikere cmc limit - bos-balance of system & integrating with dashboard for real-time energy production monitoring, grid & battery performance tracking, iot-based remote monitoring & control, smart alerts & predictive maintenance, historical data & performance analytics,web & mobile dashboard access, three phase bidirectional smart energy meter and escom energy meter approval charges, application charges, agreement making and synchronization, installation of aluminum rails, solar panels and inverters. wiring from panels to dcdb, dcdb to inverter, inverter to acdb, acdb to lt panel, panel to panel loop earthing, dc earthing, ac earthing and light ninga rrest or flatlaying. and comprehesive maintenance for 5 years, aluminumrailstructure,longrailorshortrailstructurefor panel mounting. end clamps and mid clamps mounting structure using spring nut and all enboltfasteners.rivetingforeach rail with epdm layer for water leak protection., provision and installation of hot-dip galvanized earthing flats, fabricated from is 2062 grade steel with 80 100 micron zinc coating for long-term corrosion resistance. the conductor arrangement includes standard 25x6 mm gi earth flat (center folded) as the main earth conductor, along with 25x3 mm gi flat as auxiliary earthing strip, deployed for interconnection of solar inverters, modules, and distribution panels to the common earthing network, design, supply, and installation of maintenance-free chemical earthing system comprising a 3-meter long, 17.2 mm dia copper-bonded electrode with 250-micron coating. the electrode is provided with backfill compound for enhanced soil conductivity and long-term stability, ensuring low-resistance grounding suitable for rooftop pv installations and associated electrical equipment protection., provision and installation of solar-grade flexible copper earthing conductor, made from high-conductivity copper (is 8130 1984 compliant) with uv-stabilized pvc insulation for outdoor durability. includes 1.1 kv, 1cx6 sq.mm green-yellow coded cable, deployed for module mounting structure and panel earthing to ensure reliable system grounding and enhanced safety in rooftop pv installations, provision and installation of solar-grade flexible copper earthing conductor manufactured from high-conductivity copper (is 8130 1984 compliant) with uv-stabilized pvc insulation. includes 1.1 kv, 1cx6 sq.mm green-yellow coded cable, deployed for module mounting structure and panel earthing to ensure reliable grounding and electrical safety in rooftop pv systems., provision and installation of solar grade flexible copper earthing conductor, manufactured from high-conductivity copper is 8130 1984 compliant, insulated with uv-stabilized pvc for long-term rooftop exposure. includes 1.1 kv, 1cx6 sq.mm green-yellow coded cable, specifically designated for inverter body earthing and safety bonding within the pv system, provision & installation of frls xlpe insulated 1.1 kv aluminum conductor h4 grade, stranded class-2 power cable, optimized for solar inverter to acdb interconnection. cable construction includes black extruded xlpe inner sheath is 5831 compliant, with galvanized steel armoring providing 90% coverage for enhanced mechanical protection, designed in accordance with is 1554/iec 60189. scope covers 4c x 25 sq.mm a2xfy cable routing and termination, integrated into rooftop photovoltaic ac distributio, custom-provision and installation of solar pv compliant dc cabling system comprising tuv-certified 1.5 kv electron-beam cross-linked xlpo insulated copper conductors with uv-resistant sheath. scope includes color-coded red and black 1cx4 sq.mm cables, optimized for rooftop photovoltaic string interconnections, supply and installation 8-in8-out dcdb1000vdc,ip65,iec certified, iot-compatible for remote monitoring voltage and current , ip 65 enclosur
Tender For corrigendum : supply of machine guarding - box 600x400x300 , machine guarding , guard for z axis , x axis rear guide way guard , cnc control post , electrical panel transformer , terminal box
Tender For supply of procurement of spare of dozer bd50 and bd80 sup prc d d - bd80 , ccc0107020 clamp hose radiator assy i bd50 , 110 cs 91826 1312141480 nutbd50 , 110mc21962 1411013120 lining brake inertia brake ii bd50 , 110mc11618 plate lock , 110ec91202 valve drain radiator assy i bd50 , cfk0200722 401000722 key i ii vi bd80bd50 , cfp02 11025 pin inertia brake ii bd50 , cfb01 22090 112262090 bolt , 0726002013 hose , 110mc12088 1703312360 spring inertia brake ii bd50 , 102200001421 nut , 110mc71923 1311045320 gasket main clutch booster ii bd50 , 113tf13026 1413014130 washer track frame iv bd50 , cfs0130835 0100030835 screw iii v bd50 bd80 , 113ei11014 shim 1 point 00 mm engine att parts i bd80 , cfb0721450 104051450 bolt blade lift cylinder vi bd80bd50 , cfw0211225 164211216 washer v iv vi bd80 bd50 , cfw0111030 0160211030 washer spring i ii iii iv v vi bd80 bd50 , cfw0111442 160211442 washer spring ii iii vi vii bd80 bd50 , 116tm12724 1501513350 shaft gear shift fork ii bd80 , 116tm92607 1501412641 seal oil ii ix bd80 , cfb0822760 101172760 bolt angle blade vii bd80 , 116cs91394 1752211240 ring seal steering clutch iii bd80 , 116co91294 1504332520 knob shift control ii bd80 , 113eg91119 charge lamp instrument panel i bd80 , 116fd11687 1752712181 bolt reamer sprocket and shaft iii bd80 , 30z6180489 hose water pump assembly v bd80 eng , cpf1210610 720610610 bolt joint i ii bd80 , 110sk01006 1311005210 main clutch service kit , cet0402160 bty terminal negative battery i bd50 , 116tm52577 gear coupling 6m intermediate shaft ii bd80 , 116fp02006 1505441210 board floor floor board v bd80 , 116br00117 1543305012 brake service kit , chh2201004 710200504 hose steering piping iii bd80 , 116fd11492 key , 116tf12121 1703013331 bolt front idler iv bd80 , cft0121640 112041640 stud steering case iii bd80 , 116tm52893 1501511690 gear guide 5m main shaft ii bd80 , 130hs91068 1706416460 hose hydraulic tank vi bd80 , chs0115225 700005225 o ring iii ix bd80 , 116tf02272 1543011950 cover rh track frame cover iv bd80 , 125hs02009 1546011391 sight gauge hydraulic tank vi bd80 , 116co12075 1544411820 spring brake pedal iii bd80 , cfl0900115 406700115 ring snap main clutch disc ii bd80 , 116tm72179 1501513510 gasket ii ix bd80 , 116tm92931 1751416230 tube transmission case ii bd80 , chs0113048 700013048 o ring vi ix bd80 bd50 , 110mc11764 1311041470 rod main clutch plate ii bd50 , cfs0130816 100030816 screw v vi bd80 bd50 , 116flb0018 1540400013 tank assy fuel tank i bd80 , 30z5180551 30z5100985 oil cooler assy lubricating oil cooler iii bd80 eng , 116fd11402 spacer , chs0115460 700005460 o ring ii ix bd80 , 116tf11693 1503015551 spacer track roller guard iv bd80 , 116fp11135 1545412580 board floor floor board v bd80 , 31z1280188 hose intake manifold i bd80 eng , cfb0822245 104132245 bolt cylinder stay vi bd80 , 113tf13107 1413014140 lock track frame iv bd50 , 116mc92543 1501011430 lining main clutch housing ii bd80 , 130ip81082 7060300000 dash lamp instrument panel i bd80 , 116tf11911 1543011331 washer recoil spring iv bd80 , 110cs02069 case and frame assy , 10z6180196 thermostat , cfw0112472 160212472 washer spring iii iv v bd80bd50 , 30z7180377 fuel filter assy , cel2042411 lamp indicator eop //bid details 2 / 90 instrument panel i bd80 , 125eg81458 horn switch electrical system 2 2 i bd80 , 30z4110151 push rod camshaft and tappet ii bd80 eng , cfw0111957 160201957 washer spring angle blade vii bd80 , 116fp02022 1505441220 board floor floor board v bd80 , 116tf71552 1503013430 seal recoil spring iv bd80 , 116tm72227 1701412190 gasket iii ix bd80 , cfs032045 screw key , ccc0109020 728008029 clamp intake manifold i bd80 eng , 32z1100015 pipe exhaust exhaust pipe i bd80 eng , 116co91326 1504332540 knob shift control ii bd80 , 116tf71585 1503013470 ring back up recoil spring iv bd80 , 116tm11558 1501512160 lock intermediate shaft ii bd80 , chs0112055 700012055 o ring vi ix bd80 , 110os02082 seat operators ii vi bd80bd50 , 125fl02002 1540412530 strainer fuel
Tender For supply of sitc of thyristor based control system for 120 kw arm pit furnace - thyristor-150 amps capacity, 3 phase , master controller, power 100-240 v ac , slave controller, power 100-240 v ac , electrical panel for thyrister modules , hydraulic cylinder for lid operation , thermocouple, k-type cr-al, duplex , thermocouple, k-type cr-al, simplex , mi thermocouple, k-type,od-3mm,l-5mtrs , compensating cable for k-type t-c , 3.5core 35sq mm cu cable of pvc insulated , installation and commissioning